Industries / Construction and property
Fire protection and life safety
The fire protection and life safety industry designs, installs, inspects and maintains the equipment that finds a fire, warns the people inside, holds the fire back and gets them out: sprinklers, alarms and detectors, special suppression systems, extinguishers, exit signs, emergency lights and fire doors.
1874
On 11 August 1874 Henry S. Parmelee of New Haven, Connecticut, received US patent 154,076 for an automatic sprinkler, a valve on a building's water pipes held shut by a metal that melts in the heat of a fire. FM, the insurer that grew out of the Factory Mutual companies, says the Factory Mutuals championed the sprinkler's acceptance from its introduction that year.
44
Milestones achieved across 7 domains.
11
To watch for: announced, not yet confirmed outside.
15
Open deliverables. Nobody has shipped them.
In one minute
Where it started
George Manby tried a portable extinguisher of compressed air and potash solution in London in 1816, and Boston wired street fire alarm boxes to a central office in 1852. The trade as it is today grew from the automatic sprinkler, patented by Henry Parmelee in 1874 and pushed into factories by mill owners' mutual insurers, which inspected the buildings they covered. In 1896 the National Fire Protection Association (NFPA) was founded around one shared rulebook for installing sprinklers, and deadly crushes and fires in halls, theaters and factories were followed by panic bars and rules for exits.
Where it stands
Codes and standards set what each kind of building must have and how often it must be inspected and tested, and fire officials and insurers check the work. NFPA's 2026 report on US fires from 2020 to 2024 found that sprinklers operated in 90% of the fires large enough to set them off, controlled 97% of those, and that civilian deaths per fire were 90% lower where sprinklers were present; when one failed, the usual reason was that someone had shut the system off. False alarms are a large cost: in England they made up 41% of the incidents fire services attended in the year to March 2025. The chemicals in special systems keep changing, as halon production ended in 1994 and Europe restricted PFAS foams in 2025.
What is open
Many open jobs are checks that inspectors still make by eye or by hand and that a phone camera, a depth scan or an AI model could now make and be scored on: reading sprinkler markings, measuring the space under sprinklers, grading pipe interiors, measuring fire door gaps and measuring light on exit routes. Others are public records nobody has put together, such as the actions in published fire risk assessments, the approvals of fluorine-free foams, the halon destroyed for carbon credits and what happened to fires after fire services stopped answering automatic alarms. The rest are independent tests of things already sold: AI plan review, hydraulic calculation programs, report-tracking services, smoke alarms in real kitchens and extinguishers marketed for battery fires.
Domains
AchievedWatch forOpen
Domain
Progress
Last achieved
Watch for
Open
Design and code review
Design and code review is the work of laying out a building's fire protection and escape routes on paper, and of checking those plans against the fire and building codes before anything is built.
6 · 2 · 2
Last achievedA nightclub fire tightens codes2003
Watch forAI checks plans for permits
2
openSprinklers
Sprinkler work designs, installs and looks after networks of water pipes fitted with sprinklers, nozzles that open by themselves in the heat of a fire and spray water on it.
6 · 2 · 2
Last achievedWelsh homes get sprinklers2016
Watch forSound in place of water
2
openAlarms and detection
Alarms and detection is the work of sensing a fire early, by its smoke, heat or gases, then warning the people inside and calling the fire service.
7 · 1 · 2
Last achievedAlarms must ignore hamburgers2024
Watch forDetectors that ignore steam
2
openSpecial hazard systems
Special hazard work protects places where water would fail or do harm, such as computer rooms, fuel stores, aircraft hangars, ships' engine rooms and restaurant kitchens, with fixed systems that release gas, foam, wet chemical or fine water mist.
7 · 2 · 2
Last achievedEurope restricts PFAS foam2025
Watch forWater mist replacing sprinklers
2
openExtinguishers and exits
This work supplies, hangs and services portable fire extinguishers, and keeps the ways out of a building usable: exit signs, emergency lights, fire doors and the hardware that opens them.
7 · 1 · 3
Last achievedExtinguishers that would not spray2017
Watch forA test for battery-fire extinguishers
3
openInspection and testing
Inspection and testing is the routine work of checking that installed sprinklers, alarms and detectors would still work in a fire, on a schedule set by codes and insurers.
5 · 1 · 2
Last achievedInspections by video link2024
Watch forDetectors that test themselves
2
openRecords and compliance
Records and compliance is the paperwork that proves a building's fire systems were inspected and repaired, and the laws and officials that decide who must keep it and who checks it.
6 · 2 · 2
Last achievedRegulator counts overdue fire actions2024
Watch forWales widens building safety duties
2
open
Advances to build with
2 research notes

Muse Ember
The jobs agents repeat
Meta's Muse Ember matched Claude Haiku 5.5 on an outside firm's tests at a third of the cost per task, though both list the same prices for text in and out.

Cursor Agent SDK
Findings that cite notes
Cursor released a kit for building AI agents, and its example, a code reviewer that cites the note behind each finding, is known only from Cursor's account.
Open in fire protection and life safety
3 of 15 open deliverables
Open · Design and code review
Drawing test for AI review
A public test set of fire protection drawings, sprinkler layouts and fire alarm device plans for about 20 sample buildings, each with a written list of code errors placed on purpose (sprinklers spaced too far apart, a room missing a detector, an exit route that is too long) and checked by a qualified fire protection reviewer. Add a scoring script that runs AI reviewers over the drawings and counts errors found, errors missed and false findings.
Built with what exists
openly licensed building models in the IFC format; IfcOpenShell or FreeCAD to draw the layouts; vision-language models (models that read images as well as text) such as Gemini and Claude, and trial accounts of commercial checkers; the Hong Kong team's published code (github.com/Laniqiu/HK-FSCode-LLM-Eval) as a scoring template; a reviewer agent that cites the clause behind each finding (see the Note "Findings that cite notes") and a second pass that looks for what the first missed (see the Note "Seven more flagged").
Open · Sprinklers
Read sprinkler markings from photos
An open, labeled set of photos of installed sprinkler heads, taken from the floor with an ordinary phone, and a tool that reads the stamped markings, the sprinkler identification number (SIN) and the year of manufacture, names the maker and model, and flags two kinds of head: those from recalled families, such as Central's Omega and O-ring lines, and those that have reached NFPA 25's 20-, 25- or 50-year test points. Nobody touches or removes a head.
Built with what exists
Phones with a 3x to 10x optical zoom, or a camera on a pole; vision-language models that read small stamped text, such as Claude or Gemini, an open OCR library such as PaddleOCR, or an Ultralytics YOLO detector trained on the set; manufacturers' SIN tables; the CPSC SaferProducts recall API for the recalled models; Label Studio for labeling; Hugging Face to publish the set.
Open · Alarms and detection
Nuisance alarms in real kitchens
A field study, and an open dataset, of how often smoke alarms built to the eighth edition of UL 217 sound during ordinary cooking in occupied homes. In each volunteer home, mount extra alarms of each sensing type (ionization, photoelectric, dual-sensor) at 1.5 m, 3 m and 6 m (5, 10 and 20 ft) from the stove for 30 days, alongside the home's own alarms, which stay in place. A small logger records the time each test alarm sounds, a particle sensor records the smoke and grease aerosol next to it, and residents log what they cooked and how.
Built with what exists
Retail battery smoke alarms listed to UL 217 eighth edition or later; a microphone on an ESP32 or Raspberry Pi board, or a commercial sound-level logger, to timestamp each alarm's beeping; a Sensirion SPS30 particle sensor; a paper or phone cooking log; Python or R for rates and confidence intervals.