Industries / Construction and property / Fire protection and life safety
Sprinklers
Sprinkler work designs, installs and looks after networks of water pipes fitted with sprinklers, nozzles that open by themselves in the heat of a fire and spray water on it.
6
Milestones achieved, from 1874 to 2016.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1874
A heat-opened sprinkler patented
On 11 August 1874 Henry S. Parmelee of New Haven, Connecticut, received US patent 154,076 for an automatic system on a building's water pipes. Each valve is held shut by supports made of a metal that melts at a low temperature; the heat of a fire melts them, water pressure opens the valve, and water sprays through the sprinkler head, while a cap keeps water from one head off the supports of the next. FM, the insurer that grew out of the Factory Mutual companies (see Inspection and testing), says the Factory Mutuals championed the sprinkler's acceptance when it was introduced in 1874.
Credit
Henry S. Parmelee; the Factory Mutual companies
1892
Pipes sized by test
In 1892 John R. Freeman of the Factory Mutual laboratories ran a long series of tests to find the pipe sizes needed to deliver enough water to each sprinkler in a system. FM Approvals, as those laboratories are now called, says his results are still the basis for sprinkler hydraulic calculations, the arithmetic that sizes each pipe from the water pressure available. Four years later the first common US rules for installing sprinklers were written (see Design and code review).
Credit
John R. Freeman, for the Factory Mutual companies
1980
Sprinklers built for homes
The 1973 US report America Burning found that nine of every ten people who died in building fires died at home. NFPA adopted its first standard for sprinklers in one- and two-family homes, NFPA 13D, in May 1975, but it rested on committee judgment and ordinary sprinklers, and few homes installed it because of the cost. From 1976 the agency that became the US Fire Administration funded research with Factory Mutual Research Corporation, Underwriters Laboratories and NFPA that produced the "residential sprinkler", which opens faster and spreads water more evenly; in one NIST calculation for a sudden rise in gas temperature of 90 °C, a fast-response sprinkler opened in under 14 seconds, against more than 100 seconds for the slowest standard one. After full-scale test fires in Los Angeles, the 1980 edition of NFPA 13D required listed residential sprinklers and set the goal of keeping the room where a fire starts survivable, with eye-level gas no hotter than 93 °C (200 °F) and carbon monoxide below 0.15%. The same review says San Clemente, California, became the first US community to require sprinklers in all new homes, in 1980.
Credit
US Fire Administration; Factory Mutual Research Corporation; NFPA's sprinkler committee; reviewed by Daniel Madrzykowski of NIST and Russell P. Fleming of the National Fire Sprinkler Association
1989
Sprinklers that put fires out
Ordinary sprinklers are designed to control a fire, holding it in check until firefighters arrive, and tall stacks of goods in warehouses can burn too fast for that. In 1985 C. Yao of Factory Mutual Research Corporation reported large-scale tests showing that a few fast-opening sprinklers throwing large drops could suppress such fires early, and described a program to set approval criteria for early suppression fast response (ESFR) sprinklers. FM Approvals says it approved the first ESFR sprinkler in 1989, for severe storage fires beyond the reach of control-mode sprinklers. A later patent by Central Sprinkler, a rival maker, calls ESFR "a well known and well defined class" of ceiling sprinklers and dates Underwriters Laboratories' ESFR standard, UL 1767, to 1990.
Credit
C. Yao and Factory Mutual Research Corporation; FM Approvals
1998
Millions of heads recalled
On 14 October 1998 the US Consumer Product Safety Commission (CPSC) and Central Sprinkler Corp. of Lansdale, Pennsylvania, announced the recall of about 8.4 million Omega sprinklers, installed in homes, schools, hospitals, prisons, hotels and federal buildings. CPSC had reports of Omegas failing to work in 17 fires, and alleged that on average 30 to 40% of Omegas removed from buildings for testing failed to activate as they should. In January 2001 Central began replacing, free, 35 million more sprinklers with rubber O-ring seals, made from the mid-1970s to 2001, because corrosion, or minerals and other contaminants in the water, could keep the seals from letting go in a fire.
LessonA sprinkler that looks normal can be stuck shut, so the only proof is to take samples out of service and test them.
Credit
US Consumer Product Safety Commission; Central Sprinkler Corp
2016
Welsh homes get sprinklers
The National Assembly for Wales passed the Domestic Fire Safety (Wales) Measure on 16 February 2011, and it was approved by Her Majesty in Council on 7 April 2011. It required every new or converted home to have a working automatic fire suppression system, such as sprinklers. Under a 2013 commencement order it applied to care homes, children's homes and halls of residence from 30 April 2014, and to new and converted houses and flats from 1 January 2016, with exceptions such as listed buildings and buildings in conservation areas.
Credit
National Assembly for Wales; Welsh Ministers
Watch for
Sound in place of water
Sonic Fire Tech, a start-up in Ohio, is developing a system that sends low-frequency sound of about 20 Hz, below the range of human hearing, through pipework in the ceiling toward a fire that its sensors detect, to stop the flames without water or chemicals. It raised $15 million in August 2026 for testing toward approval, a process its chief executive said typically takes about three years. The company says tests on lithium-ion battery fires limited spread from cell to cell but did not put the fires out. No outside test results were found.
Achieved whena listing body such as UL Solutions or FM Approvals lists the system, or an independent laboratory publishes fire tests comparing it with sprinklers.
internationalfireandsafetyjournal.cominternationalfireandsafetyjournal.com
Claimed by
Sonic Fire Tech, April and August 2026
Automated monitors as main protection
An automated monitor is a fixed water cannon that finds a fire with thermal cameras and aims at it without a person. Fire Rover, which sells them, says FM published Data Sheet 4-14, Automated Monitor Fire Suppression Systems, in April 2026, its first guidance for such systems, and that it accepts them as the main protection in certain hard-to-sprinkler places, such as the tipping halls and bunkers of waste-fueled plants and baled wastepaper storage, where they were earlier treated as a supplement to sprinklers.
Achieved whenFM's data sheet text can be checked publicly, and outside fire-loss records show monitor-protected sites faring as well as sprinklered ones.
Claimed by
Fire Rover, July 2026
Open
01
Read sprinkler markings from photos
An open, labeled set of photos of installed sprinkler heads, taken from the floor with an ordinary phone, and a tool that reads the stamped markings, the sprinkler identification number (SIN) and the year of manufacture, names the maker and model, and flags two kinds of head: those from recalled families, such as Central's Omega and O-ring lines, and those that have reached NFPA 25's 20-, 25- or 50-year test points. Nobody touches or removes a head.
The briefCredit · unclaimed02
Check stored goods against design
A phone tool that takes photos of a warehouse's rack faces and pallet labels, estimates the commodity class of what is stored under NFPA 13 (Class I to IV, or Group A plastics) and the pallet material, compares that with the class the sprinkler system was designed for, and flags racks that may exceed it.
The briefCredit · unclaimed
Open 01 · the brief
Read sprinkler markings from photos
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open, labeled set of photos of installed sprinkler heads, taken from the floor with an ordinary phone, and a tool that reads the stamped markings, the sprinkler identification number (SIN) and the year of manufacture, names the maker and model, and flags two kinds of head: those from recalled families, such as Central's Omega and O-ring lines, and those that have reached NFPA 25's 20-, 25- or 50-year test points. Nobody touches or removes a head.
Why it is still open
CPSC's records hold seven fire sprinkler recall notices from 1998 to 2007, among them 8.4 million Omega heads and 35 million heads with O-ring seals. Nearly every sprinkler made after 31 December 2000 carries a SIN on its deflector, the metal plate that spreads the water: a code of four to seven characters whose first one or two letters name the maker. QRFS, a sprinkler parts seller, says there is no single open-access SIN database, and its Quick Finder works from a typed SIN or passes photos to its staff. UL Solutions reads each sampled sprinkler's maker, model and year at the laboratory bench. The nearest prior work is a 2023 George Mason University class project by Justin Shin, a sprinkler site surveyor, which trained image models on 342 of his own site photos to name 12 sprinkler models, reaching about 91% accuracy; it names the model, not the SIN or the year. Searches found no tool that reads the stamped markings from a photo.
saferproducts.govblog.qrfs.comblog.qrfs.comblog.qrfs.comul.comgithub.com
Built with what exists
Phones with a 3x to 10x optical zoom, or a camera on a pole; vision-language models that read small stamped text, such as Claude or Gemini, an open OCR library such as PaddleOCR, or an Ultralytics YOLO detector trained on the set; manufacturers' SIN tables; the CPSC SaferProducts recall API for the recalled models; Label Studio for labeling; Hugging Face to publish the set.
First step
Download the seven fire sprinkler recall notices through the CPSC API; then, with the owner's permission, photograph 50 sprinklers in one building at full zoom from the floor and count how many show a SIN and year a person can read.
Done looks like
At least 2,000 photos of at least 80 sprinkler models from at least five buildings, covering every recalled family in CPSC's records, with labels checked by a licensed sprinkler inspector who reads the heads up close during a routine inspection. On 300 held-out photos from buildings not in the training set, the tool reads the SIN and year correctly in at least 90% of the photos where a person can read them and finds at least 95% of recalled heads, with its false-alarm rate published.
Open 02 · the brief
Check stored goods against design
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A phone tool that takes photos of a warehouse's rack faces and pallet labels, estimates the commodity class of what is stored under NFPA 13 (Class I to IV, or Group A plastics) and the pallet material, compares that with the class the sprinkler system was designed for, and flags racks that may exceed it.
Why it is still open
The sprinkler design for a warehouse depends on the product, its packaging and its pallets, and NFPA's Brian O'Connor wrote in April 2025 that when a warehouse changes what it stores, the new goods must not exceed the hazard the sprinklers were designed for. Classifying stored goods is done by people. Nomic says its AI "analyzes commodity classifications and storage configurations against NFPA 13 sprinkler design requirements" from a project's files, but gives no accuracy figures and does not say it works from photos of the goods. The nearest research found, a 2026 University of Maryland master's thesis by Tejas Rawool, predicts how a commodity burns from two small fire tests, not from what can be seen on the shelf. Searches found no photo-based tool.
Built with what exists
Vision-language models that read packaging labels and recognize materials, such as Claude or Gemini; the commodity classification rules in NFPA 13 and FM's loss prevention data sheets; a fixed checklist of yes-or-no questions for each pallet, answered with probabilities (see the Note "A thousand questions, one pass").
First step
Photograph 50 pallet loads in a warehouse or store backroom that agrees to it, note the packaging and pallet material of each, and ask one fire protection engineer to classify them.
Done looks like
On 300 photographed pallet loads classified separately by two fire protection engineers, the tool matches their class in at least 85% of the loads they agree on, and places a Group A plastic load in a lower class in no more than 2% of cases, with photos and results published.