BRENNEN

Industries / Construction and property / Fire protection and life safety

Design and code review

Design and code review is the work of laying out a building's fire protection and escape routes on paper, and of checking those plans against the fire and building codes before anything is built.

6

Milestones achieved, from 1896 to 2003.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1896

    One rulebook for sprinklers

    In the 1890s automatic sprinklers were spreading fast, but each was fitted to its own rules, with mismatched pipe sizes and threads. After meetings in Boston from 1895, a group drafted a single standard for installing sprinkler systems, and the National Fire Protection Association (NFPA) was founded around that work on 6 November 1896. The standard, now NFPA 13, was the association's first; NFPA now publishes more than 300 codes and standards written by volunteer committees. Sources differ on who began it: NFPA's own account, as reported by Fire & Safety Journal Americas, credits insurance professionals, while the 2007 textbook Egress Design Solutions credits sprinkler makers and contractors.

    fireandsafetyjournalamericas.comcatalogimages.wiley.com

    Credit

    the founders of NFPA

  2. 1913

    A committee for exits

    Two years after the Triangle Shirtwaist Factory fire in New York, NFPA's Executive Committee voted on 28 June 1913 to create a Committee on Safety to Life. At its first meeting, on 6 November 1913, the committee chose to write standards for "methods of egress", the routes people take to leave a building, and to show how sprinklers protect lives as well as property. It published pamphlets such as Outside Stairs for Fire Exits (1916) and Exit Drills in Factories, Schools, Department Stores, and Theaters (1922), which grew into a single code for exits. That code was retitled in 1966 and has been called the Life Safety Code, NFPA 101, since its 1997 edition.

    buildingcoderesourcelibrary.comcatalogimages.wiley.com

    Credit

    NFPA's Committee on Safety to Life, chaired in 1914 by H. W. Forster

  3. 2000

    Fire modeled on a computer

    In February 2000 the US National Institute of Standards and Technology (NIST) released version 1 of its Fire Dynamics Simulator (FDS), a free program that calculates how smoke and heat move through a building in a fire. NIST's 2004 user guide said about half of the program's uses were designing smoke-control systems and estimating when sprinklers and detectors would go off, and the other half were reconstructions of real fires. FDS is in the public domain and is still developed by NIST.

    nvlpubs.nist.govpages.nist.gov

    Credit

    NIST, in cooperation with VTT of Finland

  4. 2000

    Singapore checks plans by computer

    Singapore's CORENET program, launched in 1995 by the Ministry of National Development, first tried to check building plans automatically with an application called BP-Expert, which read 2D drawings. It did not succeed, for reasons that included its focus on drawings rather than a building model, its inability to handle inconsistent data and its limited coverage of code clauses. Its successor, e-PlanCheck, started in September 2000. It checks a 3D building model in IFC, an open file format for building models, against rules such as Singapore's 20 m limit on the travel distance from any point in a flat to its exit. In 2005 the trade journal AECbytes reported it in pilot projects, with trial versions built for Norway and New York City. Singapore soft-launched the next system, CORENET X, with an automated model checker, on 18 December 2023.

    LessonCode checking by computer needs a model whose parts are labeled as walls, doors and rooms, not lines on a drawing.

    aecbytes.comwww1.bca.gov.sg

    Credit

    Singapore's Ministry of National Development and Building and Construction Authority; novaCITYNETS, which built the FORNAX platform under e-PlanCheck

  5. 2001

    Codes that state goals

    In 1994 three regional US code groups, BOCA, ICBO and SBCCI, formed the International Code Council (ICC), which published the first International Building Code and International Fire Code in 2000. In 2001 the ICC published its Performance Code for Buildings and Facilities, which Egress Design Solutions calls the first stand-alone performance building and fire code in the United States. A performance code states goals, for example that people not close to a fire must not be exposed to smoke or heat they cannot survive, and lets an engineer show by calculation how a design meets them, in place of following fixed rules. NFPA's Life Safety Code and its NFPA 5000 building code offer the same choice.

    catalogimages.wiley.com

    Credit

    International Code Council; NFPA; the Society of Fire Protection Engineers, which convened a 1996 focus group on how such a system should work

  6. 2003

    A nightclub fire tightens codes

    On 20 February 2003 a band's pyrotechnics set fire to foam lining the walls of The Station nightclub in West Warwick, Rhode Island, which had no sprinklers, and 100 people died. NIST's investigation, published in June 2005, concluded that strict adherence to the model codes of 2003 "would go a long way to preventing similar tragedies". It recommended that every state and town adopt a model code, inspect and enforce it, and employ enough plan examiners qualified to a national standard, and that codes require sprinklers in all new nightclubs and in existing ones holding more than 100 people. NFPA had already strengthened its codes, and Rhode Island required sprinklers in places of assembly holding more than 300 people from 1 July 2005.

    LessonA code protects people only where it is adopted, applied to the plans and enforced in the building.

    nvlpubs.nist.gov

    Credit

    NIST; NFPA; State of Rhode Island

Watch for

  1. AI checks plans for permits

    The International Code Council said on 24 July 2025 that it had become a reseller of eCheck, Archistar's software that uses AI to check building plans against building and zoning codes, after a pilot with 11 US cities that it said showed faster plan review and more consistent code compliance. Los Angeles County opened an eCheck pilot on 15 July 2025 for homes being rebuilt after the Palisades and Eaton fires, according to an account by the architecture firm Letter Four. Neither has published how often the software's findings matched those of human plan examiners. The Los Angeles pilot covers single-family homes, and the published descriptions cover building and zoning rules, not sprinkler or alarm plans.

    Achieved whena city or an independent reviewer publishes how often eCheck's findings agreed with human plan examiners, including on exits and fire protection.

    iccsafe.orgletterfour.com

    Claimed by

    International Code Council and Archistar, July 2025

  2. Fire engineer as protected title

    The UK government said on 17 December 2025 that it will legislate so that only registered people may call themselves fire engineers or carry out restricted fire engineering work, with writing a building's fire safety strategy as the central protected task. It accepted the principles of its Fire Engineers Advisory Panel, set up after the Grenfell Tower Inquiry found no consistent formal requirements to practice as a fire engineer, and said a public consultation will take place in 2026.

    Achieved whenParliament passes the law and a public register of fire engineers opens.

    gov.uk

    Claimed by

    UK Ministry of Housing, Communities and Local Government, December 2025

Open

  1. 01

    Drawing test for AI review

    A public test set of fire protection drawings, sprinkler layouts and fire alarm device plans for about 20 sample buildings, each with a written list of code errors placed on purpose (sprinklers spaced too far apart, a room missing a detector, an exit route that is too long) and checked by a qualified fire protection reviewer. Add a scoring script that runs AI reviewers over the drawings and counts errors found, errors missed and false findings.

    The brief
    Credit · unclaimed
  2. 02

    Shared answers for hydraulic programs

    A public set of sprinkler pipe networks, in tree, loop and grid shapes, with every input written down (pipe lengths, diameters, fittings, elevations, sprinkler K-factors, the water supply curve) and answers worked out independently by hand and by two open solvers. Run commercial hydraulic programs on the same inputs and publish how far their pressures and flows differ. Hydraulic calculation is how a designer proves the water supply can push enough water through the pipes to the sprinklers that open.

    The brief
    Credit · unclaimed

Open 01 · the brief

Drawing test for AI review

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public test set of fire protection drawings, sprinkler layouts and fire alarm device plans for about 20 sample buildings, each with a written list of code errors placed on purpose (sprinklers spaced too far apart, a room missing a detector, an exit route that is too long) and checked by a qualified fire protection reviewer. Add a scoring script that runs AI reviewers over the drawings and counts errors found, errors missed and false findings.

Why it is still open

Published tests of AI on fire codes ask questions in text, not about drawings. A Hong Kong set of multiple-choice and open questions (Qiu and others, November 2026) found proprietary models scored 80% to 90% on multiple choice, while people rated their open answers 50% to 70% accurate; it cites similar text sets for the UK and Finland (CODE-ACCORD) and South Korea (SearchFireSafety). DrawingVQA (July 2026) tests models on 33 real construction drawings with 92 questions; its abstract does not mention fire code checks. Zhang and others (2025) counted the rooms of each type on real and synthetic floor plans, by detecting doors and reasoning with a language model, and checked the counts against statutory minimums, which is one narrow kind of plan check. Nomic says its agents check drawings against the 2019 and 2025 editions of NFPA 13 and cite the section behind each finding, and the ICC's 11-city eCheck pilot gave no accuracy figures; neither Nomic's page nor the ICC's release reports a test anyone can rerun.

aclanthology.orgarxiv.orgarxiv.orgnomic.aiiccsafe.org

Built with what exists

openly licensed building models in the IFC format; IfcOpenShell or FreeCAD to draw the layouts; vision-language models (models that read images as well as text) such as Gemini and Claude, and trial accounts of commercial checkers; the Hong Kong team's published code (github.com/Laniqiu/HK-FSCode-LLM-Eval) as a scoring template; a reviewer agent that cites the clause behind each finding (see the Note "Findings that cite notes") and a second pass that looks for what the first missed (see the Note "Seven more flagged").

  1. First step

    Draw the sprinkler layout for one openly licensed warehouse model, place 20 documented spacing and coverage errors, and run two AI models over it.

  2. Done looks like

    20 drawing sets with at least 200 placed errors, an answer key signed off by a qualified reviewer, and published recall (share of errors found) and false-finding rates for at least three AI tools and one human plan reviewer.

Open 02 · the brief

Shared answers for hydraulic programs

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public set of sprinkler pipe networks, in tree, loop and grid shapes, with every input written down (pipe lengths, diameters, fittings, elevations, sprinkler K-factors, the water supply curve) and answers worked out independently by hand and by two open solvers. Run commercial hydraulic programs on the same inputs and publish how far their pressures and flows differ. Hydraulic calculation is how a designer proves the water supply can push enough water through the pipes to the sprinklers that open.

Why it is still open

The only open-source sprinkler calculator found, Sprinkle (GNU GPL license, written in 2002), states that it has not been well tested or independently verified, and that its author has not checked any solutions by hand. The maker of the HYENA sprinkler program says it accepts no responsibility for the accuracy of its programs and that "the responsibility for the accuracy and validity of all conclusions" rests with the user. The last published comparison of sprinkler hydraulics programs found is B. W. Melly's in Fire Technology in 1989, of programs for the IBM PC. Searches of the web and GitHub found no shared set of reference networks with published answers; the open sprinkler tools on GitHub are calculators and layout helpers.

sprinkle.sourceforge.netapp.acadsbsg.com.aufiredoc.nist.gov

Built with what exists

EPANET, the US Environmental Protection Agency's public-domain pipe network solver, and WNTR, the agency's Python package built on it, both of which can use the Hazen-Williams friction formula that sprinkler programs use for water-filled pipe; Sprinkle; Python; trial licenses of commercial programs such as HYENA+; Zenodo to publish the set with a DOI.

epa.govusepa.github.io

  1. First step

    Work a four-sprinkler tree system by hand, model it in EPANET and in Sprinkle, and compare the pressure at each node.

  2. Done looks like

    30 reference networks whose independent answers agree within 1 psi (0.07 bar) at every node, and a published table of differences for at least three programs.