This work supplies, hangs and services portable fire extinguishers, and keeps the ways out of a building usable: exit signs, emergency lights, fire doors and the hardware that opens them.

7

Milestones achieved, from 1816 to 2017.

1

To watch for: announced, not yet confirmed outside.

3

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1816

    A portable fire engine

    George William Manby, an army barrack master at Great Yarmouth, England, built copper vessels in which "condensed air", meaning compressed air, drove a jet of water mixed with pearl ash, a potassium salt that he found kept wood from bursting into flame again. In his own account, printed in 1830, he says he first tried the apparatus in London in early 1816. A public test followed at the Woolwich practice ground on 24 March 1817, on a wooden hut stuffed with tar barrels, and its report found that "the flames were uniformly extinguished where the liquid could be applied". Many later histories date the invention to 1818. Manby meant it to hold a fire until the engines came, not to replace them: in a trial he describes, one man with a hand cart was spraying a roof in under two minutes, while a twelve-man engine crew took more than eighteen to get water on.

    LessonThe case for a portable extinguisher was speed in the first minutes of a fire, and it is still placed and taught that way.

    archive.org

    Credit

    George William Manby

  2. 1883

    A bolted door kills 183

    On 16 June 1883, at the end of a children's show at the Victoria Hall in Sunderland, England, children ran down a staircase toward free toys and met a door bolted partly open, leaving a gap of about two feet. 183 children aged 3 to 14 were crushed to death. Parliament made two inquiries and never found who bolted the door. The Public Health Acts Amendment Act 1890 then let town councils require that any building used as "a place of public resort" have "ample, safe, and convenient means of ingress and egress", kept "free and unobstructed", with inspectors and fines of up to £20. Mental Floss reports that the laws that followed required halls to have enough exits with doors that open outward.

    LessonAn exit that staff can lock or wedge is not an exit, so the law came to cover how exits are kept as well as how many there are.

    mentalfloss.comirishstatutebook.ie

    Credit

    the UK Parliament (the 1890 Act)

  3. 1908

    The panic bar

    A fire at the Iroquois Theatre in Chicago on 30 December 1903 killed 596 people, by the count of the Encyclopedia of Indianapolis. Carl Prinzler, who ran the builders' hardware department of the Vonnegut Hardware Company in Indianapolis, worked with his neighbor Henry DuPont, an architectural engineer, on a latch that opens when anyone pushes a bar across the door, now called a panic bar. They applied for patents for an "Emergency Exit Attachment for Knob Latches" in October 1908, the first one was reportedly fitted to a door of an Indianapolis high school that year, and Vonnegut began selling the Von Duprin Safe Exit Device in 1910.

    indyencyclopedia.org

    Credit

    Carl Prinzler, Henry H. DuPont and the Vonnegut Hardware Company

  4. 1984

    A running man for exits

    In 1979 a Japanese fire agency held a design contest for an exit sign, and Yukio Ota's figure running through a doorway came out of it. The People's Graphic Design Archive says the Japanese government tested the design, sent it to the International Organization for Standardization (ISO) in 1980, and that ISO adopted it in 1984; Wikipedia gives 1985 (citing the Vancouver Sun) or 1987 (citing a Japanese government source). It is now sign E001 in ISO 7010, the international catalog of registered safety signs, so the way out can be found without reading the local language.

    peoplesgdarchive.orgen.wikipedia.org

    Credit

    Yukio Ota; the Japanese government; ISO

  5. 2004

    Exit paths that glow

    New York City's Local Law 26 of 2004 requires photoluminescent markings, which soak up light and glow after the power fails, on doors leading to exits and in exit stairs of high-rise buildings, to be in place by July 2006. It came from the city's World Trade Center Building Code Task Force, and partly from the failure of battery-powered emergency lighting during the 1993 bombing of the World Trade Center. A study by Canada's Institute for Research in Construction found that people who did not know a stairwell got down one marked this way about as fast as a fully lit one.

    facilitiesnet.com

    Credit

    New York City; the World Trade Center Building Code Task Force

  6. 2007

    Fire doors checked yearly

    A fire door only works if it is closed and latched with small gaps, so NFPA 80, the US standard for fire doors, requires in its 2007 edition that every fire door assembly be inspected and tested at least once a year, with a signed written record kept for the authority having jurisdiction, the official who enforces the code. The check covers nine points, among them holes or broken parts, the gaps around and under the door, self-closing devices, latches, labels and edge seals. The inspector must know how the door's parts work, but NFPA 80 requires no certificate. The rule binds a building only where a state or city adopts that edition, as Maine and Massachusetts had by 2009.

    idighardware.com

    Credit

    the National Fire Protection Association; explained by Lori Greene of Allegion

  7. 2017

    Extinguishers that would not spray

    On 2 November 2017 Kidde recalled about 37.8 million fire extinguishers with plastic handles in the United States and 2.7 million in Canada, covering 134 models made between 1 January 1973 and 15 August 2017. They could clog or need too much force to discharge, and the nozzle could come off with force. Kidde knew of about 391 reports of failed or limited discharge or nozzle detachment, about 16 injuries and a 2014 death after a car crash, where emergency responders could not get the recalled extinguishers to work. In 2015 Kidde had recalled 4.6 million disposable extinguishers with plastic valves for failing to fully discharge.

    LessonA fault in extinguishers made over 44 years came to light through reports of failures when people tried to use them.

    saferproducts.govsaferproducts.gov

    Credit

    the US Consumer Product Safety Commission (CPSC) and Kidde

Watch for

  1. A test for battery-fire extinguishers

    The third edition of ISO 3941, the international classification of fires, published on 21 January 2026, adds a Class L for fires in lithium-ion cells and batteries. On 15 October 2026 BSI released BS EN 3-11:2026, the European test method and marking for portable extinguishers "suitable to be used on small rechargeable lithium-ion battery fires", for batteries up to 600 Wh such as those in phones, power tools, toys, drones and bicycles, and not for vehicle or forklift batteries. Until now products sold for battery fires have rested on their makers' claims: in May 2026 the Tasmania Fire Service wrote that no extinguisher in Australia can be certified as effective on lithium-ion battery fires, and that Class L has no standing there until Standards Australia adopts it.

    Achieved whenextinguishers certified to EN 3-11 by a third party are on sale and a laboratory not paid by the maker publishes its results.

    internationalfireandsafetyjournal.comen-standard.eufire.tas.gov.au

    Claimed by

    ISO and the European standards body CEN, through BSI in the UK, 2026

Open

  1. 01

    Fire door gaps by photo

    A phone app or script that measures the gaps around a closed fire door, at the top, both sides, between the leaves of a pair and at the bottom, from photos taken with a printed reference card held in the frame, and flags each gap against the limit for that type of door.

    The brief
    Credit · unclaimed
  2. 02

    Exit light in a blackout

    A survey kit that measures the light falling on the floor along an exit route during the building's 90-minute emergency lighting test, logs each reading with its position, and maps the route against the code limits at the start and the end of the test.

    The brief
    Credit · unclaimed
  3. 03

    Battery-fire extinguisher claims checked

    A public table of the portable extinguishers and fire blankets sold for lithium-ion battery fires in at least three countries, with what each claims, which test it names (the maker's own, the Dutch NTA 3811, EN 3-11 or none), who ran the test, the battery size tested, and whether the test report is public.

    The brief
    Credit · unclaimed

Open 01 · the brief

Fire door gaps by photo

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A phone app or script that measures the gaps around a closed fire door, at the top, both sides, between the leaves of a pair and at the bottom, from photos taken with a printed reference card held in the frame, and flags each gap against the limit for that type of door.

Why it is still open

Inspectors measure gaps by hand with a gauge, and the inspection apps on sale record what the inspector types in; DoorTRACE, for one, says its app "lets inspectors record actual gap measurements against a door". The limits are small: NFPA 80 allows 1/8 inch (3.2 mm), plus or minus 1/16 inch, at the top and sides of a steel door and 3/4 inch (19 mm) at the bottom, and UK guidance commonly asks for 2 to 4 mm at the top and sides. A search of GitHub found one 2020 Chinese image-processing project for fire door safety checks, with no description of what it measures, and no gap-measuring code.

doortrace-website.pages.devidighardware.comgithub.com

Built with what exists

A phone camera; a printed ChArUco marker card, read with OpenCV, to set the scale and correct for the camera's angle; OpenCV edge detection or a segmentation model such as Meta's Segment Anything to find the door and frame edges; Python.

  1. First step

    Print a marker card, photograph ten ordinary interior doors with gauge readings taken at marked spots, and see how close a simple edge-detection script gets.

  2. Done looks like

    On at least 100 doors, gaps measured from photos agree with a feeler gauge to within 1 mm for 95% of measurements, and the pass or fail call matches a trained inspector's for at least 95% of doors, with the photos and readings published.

Open 02 · the brief

Exit light in a blackout

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A survey kit that measures the light falling on the floor along an exit route during the building's 90-minute emergency lighting test, logs each reading with its position, and maps the route against the code limits at the start and the end of the test.

Why it is still open

The US Life Safety Code, NFPA 101, sets emergency lighting at an average of at least 1 foot-candle (10.8 lux) along the exit path at floor level, with no point below 0.1 foot-candle, falling to no less than 0.6 and 0.06 by the end of 90 minutes, and a ratio of brightest to dimmest point of no more than 40 to 1. The routine tests it names are functional tests, by hand or by self-testing units, of whether the lights work. Phone-based light surveys exist: in November 2026 a Texas A&M datathon team mapped campus paths at night with an iPhone camera turned into a light meter. No tool or published survey was found that measures exit routes during the emergency lighting test.

csemag.comgithub.com

Built with what exists

A data-logging lux meter, or a phone camera behind a paper diffuser calibrated against one, as the Texas A&M team did; a wheeled cart with a wheel encoder, or a small mobile robot such as a TurtleBot 4, to log position; the building's floor plan; Python.

  1. First step

    Borrow a lux meter, calibrate a phone against it, and ask a school or office building manager to let you walk one stairwell during their next scheduled emergency lighting test.

  2. Done looks like

    Ten buildings surveyed with the owners' permission, with readings every half meter along each route at the start and end of the test, repeat readings within 10% of a calibrated meter, and a published count of routes that meet each limit.

Open 03 · the brief

Battery-fire extinguisher claims checked

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of the portable extinguishers and fire blankets sold for lithium-ion battery fires in at least three countries, with what each claims, which test it names (the maker's own, the Dutch NTA 3811, EN 3-11 or none), who ran the test, the battery size tested, and whether the test report is public.

Why it is still open

The Australasian fire services' council AFAC warned in 2024 that such products were being sold with claims that no Australian test or certification could validate, and the Tasmania Fire Service repeated the warning in May 2026; neither names products. A web search found no product-by-product table and no independent consumer test. EN 3-11, released in October 2026, gives the first common European yardstick to check the claims against.

afac.com.aufire.tas.gov.au

Built with what exists

A browser agent such as Browser Use (see the Note "Deleting 80% to start over") to collect product pages slowly and within each site's rules; a low-cost extraction model such as Muse Ember (see the Note "The jobs agents repeat") to pull the claims and named tests from each page; a spreadsheet; emails to makers asking for test reports. No battery is set on fire.

  1. First step

    List the battery-fire extinguishers and blankets sold by five large retailers in the UK and Australia and record the test each page names.

  2. Done looks like

    At least 50 products from at least three countries, every claim and its evidence linked, a tally by type of evidence, and a second person checking ten rows against the pages.