Industries / Construction and property / Fire protection and life safety
Inspection and testing
Inspection and testing is the routine work of checking that installed sprinklers, alarms and detectors would still work in a fire, on a schedule set by codes and insurers.
5
Milestones achieved, from 1835 to 2024.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1835
Insurers inspect the mills
Zachariah Allen, a Rhode Island textile mill owner, improved his mill to cut the chance of fire and asked his insurer for a lower premium. When it refused, he and other mill owners formed a mutual insurer that covered only well-protected factories and returned unused premiums to its members. The group became known as the Factory Mutuals, and FM, the insurer it became, says that "proper fire prevention methods and inspections resulted in dramatically fewer losses". The Factory Mutual companies merged into one insurer, now called FM, in 1999.
Credit
Zachariah Allen and the Factory Mutual companies, by FM's own account
1951
A lamp shows the test
Cerberus's F3 smoke detector, introduced in 1951, was the first with an alarm indicator built into its base, by Siemens's account, so a person testing it could see at once whether that detector had reacted to test smoke. About 100,000 were made, against about 10,000 of the earlier F2 in its first five years.
Credit
Cerberus, by the account of Siemens, which now owns it
1992
One rulebook for water systems
NFPA 25, the Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, was first issued in 1992, according to the National Fire Sprinkler Association, and is revised every three years; the 2026 edition is current. It covers sprinklers, standpipes and hose, water spray and foam-water systems. As summarized by UL Solutions, the 2026 edition requires sprinklers to be replaced, or a sample sent to a laboratory for testing, after 50 years in service; after 20 years for ESFR (early suppression fast response) storage sprinklers and for dry sprinklers; after 25 years for other fast-response types; and every five years in harsh places such as foundries. A sample is at least four sprinklers or 1% of those in the area, whichever is greater.
Credit
National Fire Protection Association
2017
Old sprinklers change a test
UL Solutions tests sprinklers that are taken out of buildings under NFPA 25's sampling rules and shares the results with the NFPA committee and others. It says the results showed how far the operating performance of ESFR sprinklers had degraded in service, and that this supported revisions to UL 199, the standard new sprinklers are tested to, adding harder corrosion tests that took effect in 2017. In its 2023 analysis, most standard-response samples were at least 50 years old, and apart from known problems in one type of seal the samples still performed well.
LessonTesting sprinklers taken from real buildings shows which designs age badly, and the results feed back into the tests new sprinklers must pass.
Credit
UL Solutions; the NFPA 25 technical committee
2024
Inspections by video link
NFPA published a 2024 edition of a new standard, NFPA 915, Standard for Remote Inspections and Tests; its next edition is due in 2027. Its 2021 public draft defined a remote inspection as one done with audio and video devices or other technology, so that an inspector or the authority having jurisdiction (AHJ, the official who enforces the code) can watch from elsewhere on the site or off it, and it allowed inspection by small drones with the AHJ's approval. The draft's stated purpose was a result "equivalent or improved" compared with other inspection methods.
Credit
National Fire Protection Association
Watch for
Detectors that test themselves
Honeywell sells addressable smoke detectors that put a small amount of smoke and heat into their own chambers and check that the smoke entry openings are not blocked, which it says meets NFPA 72's requirements for functional and smoke entry testing without canned smoke or heat guns. In January 2026 Michael Troiano, president of Global Fire at Honeywell, wrote that self-testing cuts the commissioning of a 400-detector system by about 2.5 days and the test team from two or three people to one.
Achieved whenan independent party, such as a testing laboratory, insurer or AHJ, publishes a time study and shows that the self-tests catch the same failed detectors a smoke test does.
Claimed by
Honeywell, January 2026
Open
01
Clearance measured from the floor
A public accuracy test of measuring, from floor level with a phone, the gap between each sprinkler and the top of the stored goods below it. Sprinklers need clear space beneath them to spray properly; the vendor named below checks for at least 18 in (46 cm). Build a set of phone depth scans and photos of storage rooms, each sprinkler's gap measured by hand, and a script that scores any method, from a phone's depth sensor to an AI model, against those measurements.
The briefCredit · unclaimed02
Grade pipe interiors from photos
An open set of photos and video frames of the inside of sprinkler pipes, gathered from the five-yearly internal checks that contractors already make, each labeled for foreign material, tubercles (rust nodules), slime and the pitting typical of microbiologically influenced corrosion (MIC, corrosion driven by bacteria), and for whether a fuller obstruction investigation followed; plus a model and a scoring script that grade new photos the same way.
The briefCredit · unclaimed
Open 01 · the brief
Clearance measured from the floor
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public accuracy test of measuring, from floor level with a phone, the gap between each sprinkler and the top of the stored goods below it. Sprinklers need clear space beneath them to spray properly; the vendor named below checks for at least 18 in (46 cm). Build a set of phone depth scans and photos of storage rooms, each sprinkler's gap measured by hand, and a script that scores any method, from a phone's depth sensor to an AI model, against those measurements.
Why it is still open
A vendor, iFactory, says its robots use "visual AI" to check that sprinklers have at least 18 inches of space below them and claims a 92% reduction in undetected fire hazards, but it publishes no method or test data. Dematic, a warehouse automation company, has flown drones over racks in German warehouses since 2022 and lists sprinkler systems among the things they look at, again with no published clearance measurements. Searches found no independent accuracy test of measuring sprinkler clearance from photos or scans.
Built with what exists
An iPhone or iPad Pro with a LiDAR depth sensor and Apple's RoomPlan or ARKit, or the Polycam app; an open depth-from-photo model such as Depth Anything V2; a vision-language model such as Claude or Gemini to find sprinkler heads and the tops of stacks; a laser distance meter, used from the floor, measuring floor-to-sprinkler and floor-to-top-of-stack, as the reference.
First step
In one storeroom you have permission to use, laser-measure 30 sprinklers from the floor, scan the room with a LiDAR phone, and compare the two.
Done looks like
At least 500 sprinklers in at least 10 storage rooms or warehouses, a published dataset, and a reported mean error in centimeters and pass/fail agreement at the 46 cm line for each method tested.
Open 02 · the brief
Grade pipe interiors from photos
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open set of photos and video frames of the inside of sprinkler pipes, gathered from the five-yearly internal checks that contractors already make, each labeled for foreign material, tubercles (rust nodules), slime and the pitting typical of microbiologically influenced corrosion (MIC, corrosion driven by bacteria), and for whether a fuller obstruction investigation followed; plus a model and a scoring script that grade new photos the same way.
Why it is still open
The check is made by eye. As Louis Guerrazzi of the Society of Fire Protection Engineers describes it, the usual method is to drain the system, open flushing connections or remove pipe sections where corrosion is likeliest, look inside, keep samples of anything found and take photographs "for records"; a camera on a snake fed through the pipes is the most thorough alternative. If corrosion or an obstruction is found, a full obstruction investigation is likely to follow. Searches found labeled image sets and models for sewer, drain and water-main pipes, and none for sprinkler piping.
Built with what exists
Contractors' existing assessment photos, shared with the building owners' permission and with addresses removed; new footage from a plumber's inspection camera during scheduled assessments; Label Studio; an Ultralytics YOLO model or a vision-language model such as Claude or Gemini; Hugging Face to publish the set.
First step
Ask two sprinkler contractors for the photos from their last ten five-year assessments, with building details removed, and label 200 of them with one inspector to set the categories.
Done looks like
At least 3,000 images from at least 100 systems, each labeled independently by two experienced inspectors with their agreement reported, and the model's agreement with the inspectors measured on 500 held-out images from systems it has not seen.