BRENNEN

Industries / Industrial equipment and services / Industrial services

Cathodic protection and corrosion control

Cathodic protection and corrosion control is the work of keeping buried and submerged steel, such as pipelines, tanks, ship hulls and offshore foundations, from corroding, by coating it and by driving a small direct current onto it, from metal anodes that corrode in its place or from a powered supply.

1824

On 22 January 1824 Humphry Davy read a paper to the Royal Society in London showing that a small piece of zinc or iron joined to a ship's copper sheathing stops seawater from corroding the copper; he had taken up the problem at the request of the Navy Board.

jimclifford.ca

32

Milestones achieved across 6 domains.

8

To watch for: announced, not yet confirmed outside.

12

Open deliverables. Nobody has shipped them.

In one minute

Where it started

In 1824 Humphry Davy, helped by Michael Faraday, showed that small pieces of zinc or iron stop seawater eating a ship's copper sheathing, and the Royal Navy tried the idea on its ships. A century later American pipeline engineers took it up for buried steel, and by the 1930s they powered it from the grid through rectifiers. In 1943 eleven of them founded the National Association of Corrosion Engineers (NACE) in Houston; it merged with SSPC, the coatings society, to form AMPP in January 2021.

Where it stands

A coating plus a protective current is now the standard defense for buried pipelines, tank bottoms, ship hulls and offshore structures, and US rules have required it on new gas pipelines since 1971. NACE's 2016 IMPACT study put the world's cost of corrosion at US$2.5 trillion in 2013, about 3.4% of world output, and estimated that 15 to 35% of it could be saved with practices already available. Failures still happen where the readings look fine, as at Sissonville, West Virginia, in 2012, and offshore wind farms have raised new questions about the metals that anodes release into the sea.

What is open

Much of what the trade relies on is measured privately or not at all. Makers' anode figures, scale-model tank data, survey readings over known coating holes and the accuracy of remote monitors have no open, outside checks, and the free calculators for anode design and power-line interference are untested. Each could be built with bench tanks, soil boxes, public archives and AI models that read long reports, without touching a live pipeline.

Domains

AchievedWatch forOpen

Advances to build with

1 research note

Open in cathodic protection and corrosion control

3 of 12 open deliverables

Open · Sacrificial anodes

Test anodes for a year

A public, twelve-month test of aluminum-zinc-indium anodes bought on the open market from at least five makers. Each anode is joined to a bare steel plate in a tank of seawater at the low current a real anode gives, with its current and potential logged throughout and its weight loss measured at the end, so that its capacity in ampere-hours per kilogram can be set beside its maker's figure.

Built with what exists

Polyethylene tanks of natural seawater or substitute ocean water made to ASTM D1141; mild steel plates; shunt resistors read by a small data logger, such as a Raspberry Pi with an ADS1115 converter board; silver/silver chloride reference electrodes; a balance reading to 0.01 g; the long-term test procedure in Annex C of DNV-RP-B401; anodes bought from distributors.

Credit · unclaimed

Open · Powered systems

Public tank test for models

An open benchmark for the software that predicts where protective current goes. A scale model, such as a 1:50 monopile or a coated steel tube with set holidays (small bare spots in the coating), sits in a tank of diluted seawater and is driven by a small anode at a few volts. Potentials are logged at 100 or more points and published with the geometry, the water's conductivity and polarization curves, which show how each surface's current changes with its potential, so that any finite element or boundary element program can be scored against the same measurements.

Built with what exists

An acrylic or polyethylene tank; seawater diluted in step with the model's scale, as scale-model practice requires; a potentiostat such as the PalmSens4 that TNO used; silver/silver chloride reference electrodes on a moving frame or a fixed grid; mixed metal oxide or platinized titanium wire anodes; open solvers such as Elmer (finite element) and Bempp-cl (boundary element).

Credit · unclaimed

Open · Coatings

A shared shielding test cell

An open design for a test cell that holds a coated steel panel with a loose flap of coating over a hole, leaving a gap of set width and depth between coating and steel, with small reference electrodes and pH probes at points along the gap while a low-voltage supply applies cathodic protection. Publish the drawings, the protocol and 30-day results for four coatings, FBE, polyethylene tape, three-layer polyethylene and a heat-shrink sleeve, and invite other labs to repeat it.

Built with what exists

An acrylic or 3D-printed cell; coated steel panels and plastic shims to set the gap; silver/silver chloride micro reference electrodes and micro pH electrodes; a potentiostat or a bench supply with a series resistor; salt water and a simulated soil solution; a data logger.

Credit · unclaimed

Where it sits