Industries / Industrial equipment and services / Industrial services
Cathodic protection and corrosion control
Cathodic protection and corrosion control is the work of keeping buried and submerged steel, such as pipelines, tanks, ship hulls and offshore foundations, from corroding, by coating it and by driving a small direct current onto it, from metal anodes that corrode in its place or from a powered supply.
1824
On 22 January 1824 Humphry Davy read a paper to the Royal Society in London showing that a small piece of zinc or iron joined to a ship's copper sheathing stops seawater from corroding the copper; he had taken up the problem at the request of the Navy Board.
32
Milestones achieved across 6 domains.
8
To watch for: announced, not yet confirmed outside.
12
Open deliverables. Nobody has shipped them.
In one minute
Where it started
In 1824 Humphry Davy, helped by Michael Faraday, showed that small pieces of zinc or iron stop seawater eating a ship's copper sheathing, and the Royal Navy tried the idea on its ships. A century later American pipeline engineers took it up for buried steel, and by the 1930s they powered it from the grid through rectifiers. In 1943 eleven of them founded the National Association of Corrosion Engineers (NACE) in Houston; it merged with SSPC, the coatings society, to form AMPP in January 2021.
Where it stands
A coating plus a protective current is now the standard defense for buried pipelines, tank bottoms, ship hulls and offshore structures, and US rules have required it on new gas pipelines since 1971. NACE's 2016 IMPACT study put the world's cost of corrosion at US$2.5 trillion in 2013, about 3.4% of world output, and estimated that 15 to 35% of it could be saved with practices already available. Failures still happen where the readings look fine, as at Sissonville, West Virginia, in 2012, and offshore wind farms have raised new questions about the metals that anodes release into the sea.
What is open
Much of what the trade relies on is measured privately or not at all. Makers' anode figures, scale-model tank data, survey readings over known coating holes and the accuracy of remote monitors have no open, outside checks, and the free calculators for anode design and power-line interference are untested. Each could be built with bench tanks, soil boxes, public archives and AI models that read long reports, without touching a live pipeline.
Domains
AchievedWatch forOpen
Domain
Progress
Last achieved
Watch for
Open
Sacrificial anodes
Sacrificial, or galvanic, anodes are blocks of a more reactive metal, such as zinc, aluminum or magnesium, fixed or wired to the steel, which corrode in its place and need no power supply.
5 · 1 · 2
Last achievedIndium traces wind farm anodes2025
Watch forMetal released per monopile
2
openPowered systems
Powered, or impressed current, systems drive protective current from a direct-current supply, usually a rectifier fed from the grid, through long-lasting anodes into the soil or water around the steel.
5 · 1 · 2
Last achievedRegulator favors powered systems2022
Watch forAnodes fitted by remote tools
2
openCoatings
Coatings are the layers of tar, tape, epoxy or plastic on buried and submerged steel that keep water off it, so that cathodic protection only has to protect the steel where the coating has holes.
5 · 1 · 2
Last achievedLab disbondment matched to field2010
Watch forToo much current lifts coatings
2
openSurveys
Surveys are measurements taken from the ground surface, walking or driving along a buried pipe, to find holes in its coating and places where the protective current is too weak.
4 · 3 · 2
Last achievedCoating checked after burial2023
Watch forCoating read from survey data
2
openMonitoring
Monitoring is the routine checking that protection is working: reading the voltage between the steel and the soil at test points, checking the rectifiers that supply protective current, and judging the readings against a criterion.
6 · 1 · 2
Last achievedCriteria from 1971 kept2022
Watch forRemote checks for liquid lines
2
openStray currents
Stray currents are electric currents from other sources, such as electric railways, power lines, the protection systems of neighboring pipelines and the Earth's own magnetic storms, that enter buried steel and corrode it where they leave.
7 · 1 · 2
Last achievedA storm pushes pipes positive2024
Watch forStorm corrosion called small
2
open
Advances to build with
1 research note
Open in cathodic protection and corrosion control
3 of 12 open deliverables
Open · Sacrificial anodes
Test anodes for a year
A public, twelve-month test of aluminum-zinc-indium anodes bought on the open market from at least five makers. Each anode is joined to a bare steel plate in a tank of seawater at the low current a real anode gives, with its current and potential logged throughout and its weight loss measured at the end, so that its capacity in ampere-hours per kilogram can be set beside its maker's figure.
Built with what exists
Polyethylene tanks of natural seawater or substitute ocean water made to ASTM D1141; mild steel plates; shunt resistors read by a small data logger, such as a Raspberry Pi with an ADS1115 converter board; silver/silver chloride reference electrodes; a balance reading to 0.01 g; the long-term test procedure in Annex C of DNV-RP-B401; anodes bought from distributors.
Open · Powered systems
Public tank test for models
An open benchmark for the software that predicts where protective current goes. A scale model, such as a 1:50 monopile or a coated steel tube with set holidays (small bare spots in the coating), sits in a tank of diluted seawater and is driven by a small anode at a few volts. Potentials are logged at 100 or more points and published with the geometry, the water's conductivity and polarization curves, which show how each surface's current changes with its potential, so that any finite element or boundary element program can be scored against the same measurements.
Built with what exists
An acrylic or polyethylene tank; seawater diluted in step with the model's scale, as scale-model practice requires; a potentiostat such as the PalmSens4 that TNO used; silver/silver chloride reference electrodes on a moving frame or a fixed grid; mixed metal oxide or platinized titanium wire anodes; open solvers such as Elmer (finite element) and Bempp-cl (boundary element).
Open · Coatings
A shared shielding test cell
An open design for a test cell that holds a coated steel panel with a loose flap of coating over a hole, leaving a gap of set width and depth between coating and steel, with small reference electrodes and pH probes at points along the gap while a low-voltage supply applies cathodic protection. Publish the drawings, the protocol and 30-day results for four coatings, FBE, polyethylene tape, three-layer polyethylene and a heat-shrink sleeve, and invite other labs to repeat it.
Built with what exists
An acrylic or 3D-printed cell; coated steel panels and plastic shims to set the gap; silver/silver chloride micro reference electrodes and micro pH electrodes; a potentiostat or a bench supply with a series resistor; salt water and a simulated soil solution; a data logger.
Where it sits
Broader