BRENNEN

Industries / Industrial equipment and services / Industrial services / Cathodic protection and corrosion control

Stray currents

Stray currents are electric currents from other sources, such as electric railways, power lines, the protection systems of neighboring pipelines and the Earth's own magnetic storms, that enter buried steel and corrode it where they leave.

7

Milestones achieved, from 1915 to 2024.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1915

    Fix the rails first

    Electric streetcars return their current to the power house through the rails. Where rail joints were poorly bonded, much of it ran through the earth and nearby water and gas pipes instead, and corroded the pipes where it flowed back out into the soil. This "electrolysis" appeared almost as soon as electric railways did. In Technologic Paper 52, issued on 27 December 1915, E. B. Rosa and Burton McCollum of the US Bureau of Standards reported that Britain had limited the voltage drop anywhere in the rail return to 7 volts, which forced better bonding and nearly ended the trouble there, while the United States had set no limit. The Bureau held that measures on the pipes should be secondary to a well-built rail return, and warned that draining current off one owner's pipes moved the damage onto a neighbor's.

    LessonProtecting one buried structure can shift corrosion onto the next, so stray current is best stopped at its source.

    nvlpubs.nist.govnvlpubs.nist.gov

    Credit

    E. B. Rosa and Burton McCollum, US Bureau of Standards

  2. 1978

    Corridor voltages predicted

    Power lines induce AC voltages on pipelines that share their corridor, and the published methods of the time often gave answers a factor of 10 away from measured voltages. In a program paid for by the Electric Power Research Institute (EPRI) and the American Gas Association's Pipeline Research Committee, J. Dabkowski and A. Taflove of IIT Research Institute developed a method that could be run on a programmable hand calculator. Checked against a Southern California Gas Company survey of its Mojave pipeline, it located each voltage peak and gave its size within ±20%.

    osti.gov

    Credit

    J. Dabkowski and A. Taflove (IIT Research Institute), EPRI, American Gas Association

  3. 1998

    Storm currents measured

    Geomagnetic storms, disturbances of the Earth's magnetic field set off by the Sun, drive currents along long pipelines. From 19 November 1998 the Finnish Meteorological Institute (FMI) recorded these currents at Gasum's Mäntsälä compressor station on the Finnish natural gas pipeline, by comparing a magnetometer above the pipe with one 40 km away at the Nurmijärvi observatory. The largest current in the first 11 years was 57 A, on 29 to 31 October 2003. The recordings stopped on 23 October 2023 because of a persistent noise problem, and FMI now shows modeled values.

    geophysica.fispace.fmi.fi

    Credit

    Ari Viljanen and colleagues, FMI; Gasum

  4. 2017

    AC corrosion gets criteria

    Well-coated pipelines can corrode at small coating holes where AC from a nearby power line or AC railway leaks into the soil, even when the usual −0.85 volt test is met. ISO 18086, adopted as a European standard in 2017 in place of EN 15280 and revised in 2019, sets limits for that case, starting with an AC voltage on the pipe below 15 V averaged over a period such as 24 hours. It states that the ordinary criteria of ISO 15589-1 are "not sufficient" when AC is present. A 2020 review by Andrea Brenna, Silvia Beretta and Marco Ormellese of the Politecnico di Milano found the criteria and the mechanism still "controversial."

    evs.eepmc.ncbi.nlm.nih.gov

    Credit

    ISO; Brenna, Beretta and Ormellese (review)

  5. 2017

    HVDC returns logged

    Some high-voltage direct current (HVDC) power links send current into the earth through ground electrodes, and buried pipelines nearby pick part of it up. Chinese researchers fitted remote potential monitors to 12 pipelines near 17 HVDC ground electrodes. In 2017 the electrodes caused 201 interference events totaling 657.31 hours, and interference was recorded on 1,987 km of pipeline, more in South China than in the east, center and northwest.

    doaj.org

    Credit

    Gu Qinglin and colleagues (Oil & Gas Storage and Transportation, 2021)

  6. 2023

    A number for interference

    The 1971 US gas rule asked only that operators whose lines carry stray currents keep "a continuing program" to minimize their effects. From 24 May 2023 PHMSA's rule requires interference surveys on gas transmission lines when monitoring shows a significant rise in stray current or a new source appears, and repairs within 15 months where the current density reaches 100 A/m² or more or the interference threatens safe operation. The 100 A/m² figure was recommended by PHMSA's Gas Pipeline Advisory Committee, which voted 9 to 0 for the provision.

    govinfo.govgovinfo.gov

    Credit

    PHMSA; Gas Pipeline Advisory Committee

  7. 2024

    A storm pushes pipes positive

    During the Gannon storm of 10 to 13 May 2024, the largest geomagnetic storm in about 20 years, researchers read protection data from 33 monitoring sites on New Zealand's gas pipeline network. At some sites both the pipe and buried coupons (small pieces of bare steel wired to the pipe) swung to positive voltages for long periods, which can corrode steel at coating defects; at others they fell below −2 V, low enough to risk loosening the coating.

    physics.otago.ac.nz

    Credit

    Malcolm Ingham (Victoria University of Wellington), T. Divett, C. J. Rodger (University of Otago) and M. Sigley (Firstgas), Space Weather, April 2025

Watch for

  1. Storm corrosion called small

    The same New Zealand group calculated pipe voltages for a simulated extreme storm and, from many smaller storms, the yearly corrosion they would cause. They report no site above ±500 V, the level that may damage protection equipment, but levels above ±50 V, which may be hazardous to people, at several sites. Storm-driven corrosion exceeded recommended limits at only three sites, one of them possibly affected by the local rail network.

    Achieved whencoupons or excavations at flagged and unflagged sites show metal loss that matches the predicted rates.

    ourarchive.otago.ac.nz

    Claimed by

    Ingham and colleagues, Space Weather, March 2026

Open

  1. 01

    Check open AC tools

    A public check of the free, open-source calculators for AC voltages induced on pipelines against the field measurements printed in the 1978 EPRI and American Gas Association report: enter each documented case's line currents, spacing, soil and pipe data, compute the pipe voltage profile, and publish the error at each measured peak.

    The brief
    Credit · unclaimed
  2. 02

    An open AC corrosion dataset

    A shared, open set of raw results from carbon steel coupons held under cathodic protection while a small AC current is added at fixed current densities, run on the bench to one written protocol by at least two labs. Each coupon's weight loss, deepest pit, AC and DC current density and off potential are logged over months.

    The brief
    Credit · unclaimed

Open 01 · the brief

Check open AC tools

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public check of the free, open-source calculators for AC voltages induced on pipelines against the field measurements printed in the 1978 EPRI and American Gas Association report: enter each documented case's line currents, spacing, soil and pipe data, compute the pipe voltage profile, and publish the error at each measured peak.

Why it is still open

An MIT-licensed Python simulator posted on GitHub in July 2026 (cloudivy/ac-interference) says it "has not yet been validated against a real CDEGS/SPLITS output or a published worked example." Another repository (ajrpBE/induced-voltage-pipeline, June 2025) ports a thesis appendix and shows no results. Commercial tools such as SES's CDEGS dominate this work and their test cases are not public.

github.comgithub.com

Built with what exists

The two repositories; both volumes of the 1978 report, free from OSTI (EPRI EL-904); Python; WebPlotDigitizer to read the measured voltage profiles off the report's figures.

  1. First step

    Take the Mojave pipeline case, extract its inputs and the measured profile in Figure 3-11, and run it in the July 2026 simulator.

  2. Done looks like

    Every field case in the report run through both tools, with predicted and measured voltage at each peak and the percentage error, judged against the ±20% the 1978 method achieved on the Mojave pipeline.

Open 02 · the brief

An open AC corrosion dataset

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A shared, open set of raw results from carbon steel coupons held under cathodic protection while a small AC current is added at fixed current densities, run on the bench to one written protocol by at least two labs. Each coupon's weight loss, deepest pit, AC and DC current density and off potential are logged over months.

Why it is still open

The limits disagree. ISO 18086 sets its conditions around an AC current density of 30 A/m², as a 2020 review summarizes it, and calls the subject "still controversial," while the 2023 US rule makes operators act at 100 A/m². Labs keep running such tests, each to its own set-up: Yuhan Su and colleagues at Marquette University reported tests on two pipe steels under several AC levels in June 2025, published as a paper rather than a dataset. A search of Zenodo in November 2026 found no raw AC corrosion dataset.

pmc.ncbi.nlm.nih.govgovinfo.govepublications.marquette.edu

Built with what exists

A signal generator and isolation transformer limited to a few volts, a potentiostat or a DC supply with an interrupter, 1 cm² coupons (the area ISO 18086 measures on), soil boxes or simulated soil solutions, an analytical balance reading to 0.1 mg, an optical microscope or profilometer for pits, and Zenodo for the data.

  1. First step

    Write the protocol and run a two-week pilot with six coupons at 0, 30 and 100 A/m².

  2. Done looks like

    At least 60 coupons at five AC densities from 0 to 300 A/m² in two soils, held for six months, with raw logs and weight loss on Zenodo and each corrosion rate compared with the 0.01 mm a year that the review says protection standards allow.