Industries / Industrial equipment and services / Industrial services / Cathodic protection and corrosion control
Powered systems
Powered, or impressed current, systems drive protective current from a direct-current supply, usually a rectifier fed from the grid, through long-lasting anodes into the soil or water around the steel.
5
Milestones achieved, from 1936 to 2022.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1936
Rectifiers on the pipeline
Robert James Kuhn revived cathodic protection in the United States in the 1920s, this time to make buried pipes last, as ETH Zurich's Ueli Angst tells it. Pipeline companies soon powered it from the grid through rectifiers, which turn alternating current into direct current. Starr Thayer reported in the Oil and Gas Journal in 1936 that his company had run 16 protection stations on Rectox rectifiers "with no losses due to their failure", and in an American Petroleum Institute paper he estimated that his company saved $8 to $10 of pipe reconditioning for each dollar spent on protection.
Credit
Robert J. Kuhn; Starr Thayer
1938
Wind power needs batteries
Where no power line reached, pipeline companies tried wind chargers. Dave Harrell reported in Petroleum Engineer in 1938 that one 32-volt wind charger on a 40-foot pole protected 1,000 ft of 18-inch pipe, but the pipe lost its protection 13.5 hours after the charger stopped, and he described adding two 120-ampere-hour batteries to keep the current on. On a Continental Oil line in Colorado and Wyoming with 28 wind-electric units, a recording meter showed practically no protection 35 to 40 percent of the time over four months, L. C. Secrest reported in 1944.
LessonProtection lasts only while current flows, so a supply off the grid needs storage sized for calm spells.
Credit
Dave Harrell; L. C. Secrest
1941
Tank farm leaks cut
In May 1941 a powered protection system started at a large tank farm on the Texas Gulf Coast: 63 tanks of 55,000 barrels and more than 28 miles of connecting oil line. Pit-hole leaks in the lines had averaged six a month since 1938; in the six months after the system started they averaged two, a drop of two thirds, R. A. Brannon reported in 1942.
Credit
R. A. Brannon
1999
Hull systems tuned in models
US Navy rules (chapter 633 of the Naval Ships' Technical Manual) call for powered hull protection that holds the whole wetted hull at −0.85 V, within 0.05 V, against a silver/silver chloride reference cell, both at the pier and under way. To decide where anodes and reference cells go, the Navy has made extensive use of physical scale modeling, which tests a scaled-down hull in a tank, for new designs and upgrades, allowing for up to 15% of the hull's coating to be lost.
Credit
K. E. Lucas, E. D. Thomas, A. I. Kaznoff and E. A. Hogan, in ASTM's 1999 collection on designing cathodic protection for marine structures
2022
Regulator favors powered systems
Germany's maritime agency, the BSH, and the Helmholtz-Zentrum Hereon measured components of sacrificial anodes in the water and sediment around North Sea offshore wind farms, which they say was a first. They found concentrations mostly within natural variation, with occasional peaks. The BSH, which approves offshore projects in German waters, said zinc-based sacrificial anodes were already not permitted and that operators should increasingly use impressed current systems, which it associates with very low chemical emissions.
Credit
BSH and Hereon (the OffChEm project)
Watch for
Anodes fitted by remote tools
OEG says it will supply and install impressed current systems for the monopile foundations of the 63 turbines at Skyborn Renewables' 976.5 MW Gennaker wind farm in the German Baltic, using the ICCP-Subsea Assembly Method (SAM), a remotely operated installation system it developed with the protection firm CORROSION that it says reduces installation complexity. Offshore installation is due to start in 2027.
Achieved whenthe systems are commissioned and a survey by the owner or a third party a year later shows the foundations held at the protection potential.
Claimed by
OEG, August 2026
Open
01
Public tank test for models
An open benchmark for the software that predicts where protective current goes. A scale model, such as a 1:50 monopile or a coated steel tube with set holidays (small bare spots in the coating), sits in a tank of diluted seawater and is driven by a small anode at a few volts. Potentials are logged at 100 or more points and published with the geometry, the water's conductivity and polarization curves, which show how each surface's current changes with its potential, so that any finite element or boundary element program can be scored against the same measurements.
The briefCredit · unclaimed02
An open, tested design calculator
An open-source library for the standard design arithmetic of offshore protection: current demand by surface and depth zone, coating breakdown over the design life, and anode mass and number by DNV-RP-B401, plus, for offshore wind, ISO 24656's design currents from measured water speeds. Every formula is tied to its clause, and a set of worked cases is checked by two practicing engineers.
The briefCredit · unclaimed
Open 01 · the brief
Public tank test for models
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open benchmark for the software that predicts where protective current goes. A scale model, such as a 1:50 monopile or a coated steel tube with set holidays (small bare spots in the coating), sits in a tank of diluted seawater and is driven by a small anode at a few volts. Potentials are logged at 100 or more points and published with the geometry, the water's conductivity and polarization curves, which show how each surface's current changes with its potential, so that any finite element or boundary element program can be scored against the same measurements.
Why it is still open
Model programs are checked against scale models, but the measurements stay private. TNO's 2026 check of a boundary element program against a ship scale model states that "the data that was used for the research described in the article is confidential", and the earlier checks it cites (Hack and Janeczko 1993; DeGiorgi and colleagues 1998; Wang and KarisAllen 2010) sit in journals and naval reports.
Built with what exists
An acrylic or polyethylene tank; seawater diluted in step with the model's scale, as scale-model practice requires; a potentiostat such as the PalmSens4 that TNO used; silver/silver chloride reference electrodes on a moving frame or a fixed grid; mixed metal oxide or platinized titanium wire anodes; open solvers such as Elmer (finite element) and Bempp-cl (boundary element).
First step
Drill three holidays into the coating of one steel tube in a 200-liter tank, map its potential at 50 points by hand, and post the data with a first Elmer model.
Done looks like
At least three model shapes with five coating-damage cases each, every case measured twice and released under an open license, and two open programs and one commercial program scored by their root-mean-square difference from the measured potentials.
Open 02 · the brief
An open, tested design calculator
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open-source library for the standard design arithmetic of offshore protection: current demand by surface and depth zone, coating breakdown over the design life, and anode mass and number by DNV-RP-B401, plus, for offshore wind, ISO 24656's design currents from measured water speeds. Every formula is tied to its clause, and a set of worked cases is checked by two practicing engineers.
Why it is still open
The one open cathodic protection calculator found on GitHub in November 2026 is a 2017 program for a shallow anode bed, described in Russian, with no tests; the other repositories found are monitoring firmware, teaching apps and exam guides. ISO 24656 changed the method in 2022, taking design current from long-term averaged water speeds with a mark-up factor of 1.5.
Built with what exists
Python with the pytest test framework; DNV-RP-B401, edition 2021-05, which DNV offers in full on its website; a purchased copy of ISO 24656:2022; public ocean-current data from the Copernicus Marine Service; an AI coding assistant to draft code that the engineers then check.
First step
Code the DNV-RP-B401 calculation for one simple jacket structure and compare it line by line with a hand calculation.
Done looks like
30 worked designs, covering jackets, monopiles and subsea structures, where the library's anode mass agrees with two engineers' independent hand calculations within 2%, published with the code under an open license.