Industries / Industrial equipment and services / Industrial services / Cathodic protection and corrosion control
Surveys
Surveys are measurements taken from the ground surface, walking or driving along a buried pipe, to find holes in its coating and places where the protective current is too weak.
4
Milestones achieved, from 1916 to 2023.
3
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1916
Four pins measure the soil
Frank Wenner of the US Bureau of Standards described how to measure the electrical resistivity of a large body of earth without digging it up: four electrodes set in holes in a straight line at equal spacing, with current passed through the outer two and the voltage read across the inner two. Among its uses he named working out and reducing the damage done to pipe systems by electrolysis from the return current of electric street railways.
Credit
Frank Wenner, US Bureau of Standards
1984
Gradients point to coating holes
A direct current voltage gradient (DCVG) survey switches a pipeline's protective current on and off and measures, with two probes on the ground, the small voltage the current sets up in the soil as it flows into a hole in the coating. The direction of the gradient leads the surveyor to the hole, and its size, given as %IR, rates how bad the hole is. Anode Engineering, an Australian firm that runs such surveys, says the method was developed from the early 1980s and launched in the Australian and US markets in mid-1984.
Credit
John Mulvaney (also spelled Mulvany) with Wilson Walton International, by Anode Engineering's account
2003
Surveys count as assessment
A US rule published on 15 December 2003, in force from 14 January 2004, let operators of gas transmission pipelines in high consequence areas (places where a failure would harm the most people) assess external corrosion by external corrosion direct assessment (ECDA), following the NACE International practice RP0502-2002. ECDA has four steps: review the records, survey from above ground with at least two different but complementary tools, dig and examine the pipe where the surveys point, then judge how well the process worked. The rule still names the standard, now SP0502.
Credit
NACE International (RP0502-2002); US Office of Pipeline Safety (rule)
2023
Coating checked after burial
PHMSA's gas transmission rule of 24 August 2022, in force from 24 May 2023, requires a DCVG or ACVG (alternating current voltage gradient) survey within six months of backfilling new onshore steel transmission pipe, and after a repair or replacement that backfills 1,000 feet or more. Damage rated severe, a voltage drop of more than 60% for DCVG or 70 dBµV for ACVG, must be repaired under NACE SP0502. PHMSA wrote that operators "have historically assumed that coating is functioning as intended after construction," and cited the NTSB's finding that disbonded coating had shielded the pipe at Marshall, Michigan, in 2010. NACE objected in comments that these surveys do not find coatings that block the protective current.
Credit
PHMSA; its Gas Pipeline Advisory Committee, which set the severe threshold and the six-month window
Watch for
Coating read from survey data
A team at the Texas A&M Engineering Experiment Station, funded by PHMSA, reports a Bayesian model, a statistical method that gives a range of likely values, that infers how well the coating insulates along each 2 km of pipe from close-interval potential readings and the positions of the rectifiers that supply the current. Applied to a 56 km and a 110 km pipeline, it flagged stretches near rectifiers as possible coating damage.
Achieved whenstretches the model flags are dug or surveyed by DCVG and the share confirmed is published by someone outside the team.
Claimed by
Homero Castaneda-Lopez's group, Texas A&M, June 2025
Magnetic survey reads corrosion
EMPIT, a German firm, says its current magnetometry inspection puts alternating current at frequencies from 2 Hz to 20,000 Hz on a pipe and reads the magnetic field from units on the ground, on the water or in the air, with up to 70 sensors, leaving the cathodic protection running. It says AI software separates the resistive and capacitive parts of the current at each coating hole, which tells bare steel from steel under a protective film, and that it found an active corrosion spot of about 8 cm², 17% of the wall deep, that a 2023 in-line inspection had not reported.
Achieved whenan operator or outside lab publishes a blind trial in which its active and inactive calls are checked by digs at a stated number of sites.
Claimed by
J. Stumme and Mark Glinka of EMPIT, Pipeline & Gas Journal, November 2025
DCVG from a towed trailer
Anode Engineering says its DCVG buggy, a trailer whose two insulated steel wheels, 1,500 mm apart, act as the ground probes, records a continuous trace with GPS from inside the tow vehicle. It reports an average of 40 km a day against 6 to 8 km a day for a walked survey, and sensitivity "at least three times" that of walking, from about 12 months of trials in central Australia and Queensland.
Achieved whenan operator or outside party surveys the same stretch both ways and publishes defect counts checked by digs.
Claimed by
Anode Engineering, in a submission to the Australian Pipelines and Gas Association (file dated September 2025)
Open
01
A survey test bed, published
An indoor test bed: a few meters of coated steel pipe buried in a tank of sand or soil, with coating holes of known size and position, protected by a low-voltage bench supply switched on and off by a timer. Take close-interval and DCVG-style readings over it at fixed spacing, at several soil moistures, and publish every reading together with the true holes, so that anyone can score a method that finds holes or rates coating from survey data.
The briefCredit · unclaimed02
Soil maps against old burials
A public table that sets each of the US National Bureau of Standards' buried test sites, where steel samples were buried and dug up again over decades, against the US soil survey's rating of "risk of corrosion" for uncoated steel (low, moderate or high) for the same soil, and checks whether the rating sorts the measured weight loss and pit depths.
The briefCredit · unclaimed
Open 01 · the brief
A survey test bed, published
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An indoor test bed: a few meters of coated steel pipe buried in a tank of sand or soil, with coating holes of known size and position, protected by a low-voltage bench supply switched on and off by a timer. Take close-interval and DCVG-style readings over it at fixed spacing, at several soil moistures, and publish every reading together with the true holes, so that anyone can score a method that finds holes or rates coating from survey data.
Why it is still open
Test sites with known holes have been built, but their readings were never released. In 2007 CC Technologies, a DNV company, built 38 buried sections of coated pipe with defects of known size for PHMSA and tested survey methods over them, including under stray currents; the results appear only as figures in its report. Newer methods are fitted and judged on data no one else can check: Texas A&M's model on operators' surveys, Noor and colleagues at Brunel University (2018) on operators' ECDA records, and EMPIT on its own model pipeline. Searches of GitHub, Zenodo and Hugging Face in November 2026 found no public set of close-interval or DCVG readings.
Built with what exists
Steel pipe offcuts with patch-repair epoxy or tape coating; a plastic trough of wet sand; copper–copper sulfate reference electrodes; a 12 V bench power supply and a timer relay as the interrupter; a data-logging voltmeter; Python for the scoring code.
First step
Bury a 2 m coated pipe with five drilled holes in a trough of wet sand and record one on and off potential profile over it.
Done looks like
At least 30 holes from 3 mm to 50 mm across, readings every 0.1 m at three soil moistures, released under an open license with a scoring script and one baseline method's hit rate and false calls.
Open 02 · the brief
Soil maps against old burials
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public table that sets each of the US National Bureau of Standards' buried test sites, where steel samples were buried and dug up again over decades, against the US soil survey's rating of "risk of corrosion" for uncoated steel (low, moderate or high) for the same soil, and checks whether the rating sorts the measured weight loss and pit depths.
Why it is still open
The soil survey's handbook says ratings based on one soil property "must be tempered by knowledge of other properties" and that studying soils against local experience with corrosion helps build them. Melvin Romanoff's 1957 NBS circular reports samples buried at 128 test locations; Richard Ricker's 2010 NIST reanalysis of 47 of the sites found soil chemistry for only 26; and Amr Morsy, Islam Ebo and Shiv Janardhanan of the Mineta Transportation Institute digitized the NBS tables in April 2026 and trained a model on the measured soil properties. None of them sets the sites against the soil survey's rating. David Slayter and Christopher Hitchcock (2008) proposed comparing the soil survey database with corrosion sites gathered from operators, a database that is not public.
directives.nrcs.usda.govnvlpubs.nist.govnvlpubs.nist.govtransweb.sjsu.edudoi.org
Built with what exists
NBS Circular 579 (free at nvlpubs.nist.gov) and Ricker's appendix tables; USDA Web Soil Survey and Soil Data Access for the rating by soil series and county; Python with pandas; QGIS.
First step
Take the 47 sites in Ricker's appendix, look up the soil series and town of the first ten in the circular, and find their ratings in Web Soil Survey.
Done looks like
At least 47 sites matched to a modern soil rating, a three-by-three table of rating against measured corrosion class, a rank correlation, and the matched data released.