Industries / Industrial equipment and services / Industrial services / Cathodic protection and corrosion control
Coatings
Coatings are the layers of tar, tape, epoxy or plastic on buried and submerged steel that keep water off it, so that cathodic protection only has to protect the steel where the coating has holes.
5
Milestones achieved, from 1930s to 2010.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1930s
Hot tar over the trench
From 1930 to 1950, by the account of KTA, a US coatings inspection firm, nearly all buried pipe was coated with hot coal tar or asphalt worked into a tar-soaked felt and wrapped in kraft paper, or with petroleum wax reinforced with fiber mesh, mostly applied over the trench. PHMSA, the US pipeline safety regulator, says these early tape wraps and coal tars tended to disbond, or separate from the steel, and that operators found coatings alone could not give complete protection, so they added cathodic protection.
LessonCoatings alone did not stop buried pipe from corroding.
Credit
pipeline builders and operators of the period; no single inventor is named in the sources
1960
Epoxy powder fused on
Fusion-bonded epoxy (FBE) is an epoxy powder sprayed onto hot pipe, where it melts, flows and cures into a hard layer. A 3M technical brief, citing Alan Kehr's 2003 NACE book on FBE, says the first FBE-coated line pipe went into service in 1960. Canada's National Energy Board wrote in 1996 that mill-applied FBE arrived there in the early 1970s and had become the most common coating, and PHMSA calls FBE the most widely used pipe coating today.
Credit
not named in the sources opened; 3M, an FBE maker, gives the date
1995
Polyethylene's European record
J. G. Haimbl and J. Geiser reported that two-layer and three-layer polyethylene coatings had been used in Continental Europe for more than 30 years, while FBE prevailed in the US and UK. The three-layer system, as Mannesmann describes it, is an epoxy primer, an adhesive and a thick polyethylene jacket. Surveys of Ruhrgas pipelines found fewer and smaller coating defects on polyethylene-coated pipe than on bitumen-coated pipe, and most defects at field joints, the welds coated on site. The authors found disbonded polyethylene in a few cases but no corrosion or cracking under it, and noted that better coatings make protection from AC interference by nearby power lines harder and more costly.
LessonWith a good factory coating, the weak point moves to the joint coated in the field.
Credit
J. G. Haimbl and J. Geiser; Ruhrgas (pipeline surveys)
1996
Tape coatings and cracking
A public inquiry by Canada's National Energy Board found that stress corrosion cracking, cracks grown by stress in a corrosive setting, had caused 22 pipeline failures in Canada since 1977, 12 of them ruptures, mostly since 1985 on lines coated with polyethylene tape and laid between 1968 and 1973. Polyethylene tape carried 73% of the failures from near-neutral pH cracking. The tape tents over the raised seam weld and comes loose at its overlaps, and because it is a good insulator it shields the steel from the protective current; loose asphalt and coal tar soak up water and let the current through. No cracking had been reported on pipe coated with extruded polyethylene or FBE.
LessonA coating that insulates well can block the protective current once it comes loose.
Credit
National Energy Board (inquiry MH-2-95)
2010
Lab disbondment matched to field
DNV Columbus, working for PHMSA, compared laboratory cathodic disbondment tests, in which current is driven into a deliberate hole to see how far the coating lifts, with coatings from pipe taken out of service and examined in the ditch, and set out a standard lab procedure. On FBE and coal tar enamel, areas of cathodic disbondment also had low adhesion. The strongly alkaline conditions thought to drive disbondment appeared only right next to the hole, with near-neutral pH a short distance away, and disbondment often spread beyond the starting hole.
Credit
Sean Brossia, DNV Columbus (report for PHMSA)
Watch for
Too much current lifts coatings
In PHMSA-funded tests, a team from the University of Akron, Marquette University and Rutgers University held FBE, liquid epoxy and polyethylene tape panels with a 3.2 mm hole at −0.775, −1.5 and −2.923 V against a calomel reference, from normal protection to heavy overprotection. FBE barely disbonded over 30 days at the normal level, and both epoxies lifted more as the potential went more negative; the tape showed no clear trend in disbonded area, but corrosion products at the hole grew.
Achieved whenthe final report gives a model of coating life against protection level and another lab repeats the trend.
Claimed by
Qixin Zhou, Qindan Huang and Hao Wang, annual report of 30 September 2025; the project runs to 29 September 2026
Open
01
A shared shielding test cell
An open design for a test cell that holds a coated steel panel with a loose flap of coating over a hole, leaving a gap of set width and depth between coating and steel, with small reference electrodes and pH probes at points along the gap while a low-voltage supply applies cathodic protection. Publish the drawings, the protocol and 30-day results for four coatings, FBE, polyethylene tape, three-layer polyethylene and a heat-shrink sleeve, and invite other labs to repeat it.
The briefCredit · unclaimed02
Field joints, tested by outsiders
A blind outside comparison of commercial field-joint coatings, the coatings put on by hand over the welds between factory-coated pipes: about eight products, such as two-layer and three-layer heat-shrink sleeves, liquid epoxy, polyurethane, and viscoelastic and butyl tapes, each applied to blasted pipe offcuts by its maker's instructions and put through a 28-day cathodic disbondment test at room temperature and at 65 °C. Someone who does not know which product is which measures the disbonded radius on every sample.
The briefCredit · unclaimed
Open 01 · the brief
A shared shielding test cell
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open design for a test cell that holds a coated steel panel with a loose flap of coating over a hole, leaving a gap of set width and depth between coating and steel, with small reference electrodes and pH probes at points along the gap while a low-voltage supply applies cathodic protection. Publish the drawings, the protocol and 30-day results for four coatings, FBE, polyethylene tape, three-layer polyethylene and a heat-shrink sleeve, and invite other labs to repeat it.
Why it is still open
A 2024 review by Abdelkader Meroufel, Andrew Gordon and Dominique Thierry of RISE, Sweden, says results on cathodic protection under disbonded coating "are difficult to compare due to the variation in the experimental set-up". The common tests measure disbondment, not shielding: ASTM's G8 compares how far coatings lift and warns that the same disbondment on two coatings "may not represent equivalent loss of corrosion protection". Saudi Aramco patented a test cell in 2022 (US 11,467,083) that measures how much protective current passes through a free film of coating, not under a loose flap, and DNV's 2010 procedure for PHMSA standardized the study of what causes disbondment, not of current under the flap.
link.springer.comstore.astm.orgimage-ppubs.uspto.govprimis.phmsa.dot.gov
Built with what exists
An acrylic or 3D-printed cell; coated steel panels and plastic shims to set the gap; silver/silver chloride micro reference electrodes and micro pH electrodes; a potentiostat or a bench supply with a series resistor; salt water and a simulated soil solution; a data logger.
First step
Build one cell from a coated test panel and a 0.5 mm shim and log the potential at three depths for a week.
Done looks like
Three labs run the same four coatings in the same cell and publish potential and pH at four depths into the gap after 30 days, with the spread between labs stated for each reading.
Open 02 · the brief
Field joints, tested by outsiders
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A blind outside comparison of commercial field-joint coatings, the coatings put on by hand over the welds between factory-coated pipes: about eight products, such as two-layer and three-layer heat-shrink sleeves, liquid epoxy, polyurethane, and viscoelastic and butyl tapes, each applied to blasted pipe offcuts by its maker's instructions and put through a 28-day cathodic disbondment test at room temperature and at 65 °C. Someone who does not know which product is which measures the disbonded radius on every sample.
Why it is still open
Field joints are where the defects gather. Haimbl and Geiser found most coating defects on Ruhrgas's polyethylene-coated lines at field joints, and the 2024 RISE review cites an industry survey (Tan and colleagues) in which 90% of corrosion damage occurred under coatings that shield the current or under heat-shrink sleeves. The nearest outside comparison found is Richard Norsworthy's 1999 rating of tape and sleeve coating types by their properties, not a test of named products. The PHMSA-funded Akron work compares FBE, liquid epoxy and tape, not field-joint products.
Built with what exists
Grit-blasted pipe offcuts; the products bought through normal suppliers; a bench DC supply or potentiostat and a reference electrode; 3% salt water; a thermostatic water bath; calipers and a camera; a published test method such as ASTM G8 as the protocol.
First step
Buy three sleeve products and run one 28-day room-temperature test on two samples of each.
Done looks like
Eight products with three samples each at two temperatures, the disbonded radius in millimeters for every sample, measured blind, with all photos and raw data online.