BRENNEN

Industries / Transport and vehicles / Warehousing and distribution / Cold-chain logistics

Temperature tracking

Temperature tracking is measuring how warm or cold goods are through storage and transport, keeping the record, and proving afterwards that they stayed in range.

7

Milestones achieved, from 1996 to 2017.

3

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1996

    Heat labels on vials

    A time-temperature indicator is a label that changes color with the heat it has taken up over time. WHO staff proposed one small enough for a single vaccine vial in 1979. PATH, a non-profit in Seattle, built prototypes for measles vaccine and then worked with LifeLines Technology (now Temptime) on a faster chemistry for oral polio vaccine, which heat spoils more quickly. By 1996 all oral polio vaccine bought by UNICEF carried one of these vaccine vial monitors. By PATH's count more than one billion had been used by June 2005, and a validation study commissioned by WHO found that the label tracked the potency of polio vaccine from all four suppliers to UN agencies.

    LessonPATH's history records that the label maker once gave up on the work, and that UNICEF asked suppliers for the labels for years before it could make them comply. Seventeen years passed between the idea and routine use.

    media.path.org

    Credit

    WHO; PATH; LifeLines Technology

  2. 2005

    Frozen food gets recorders

    An EU directive of 1992 required that the air temperature around quick-frozen food be monitored in transport, warehouses and storage, but no European standard for the instruments existed then. After the European Committee for Standardisation issued standards in 1999 and 2001, Commission Regulation (EC) No 37/2005 required recording instruments to comply with EN 12830, EN 13485 and EN 13486 from 1 January 2006, and required dated records to be kept for at least one year. Instruments already installed could stay in use until the end of 2009.

    LessonA recording rule can end before the chain does. Retail display cabinets and small cold rooms in shops were exempted, because recorders were judged "excessive" for small equipment.

    eur-lex.europa.eu

    Credit

    European Commission; European Committee for Standardisation (CEN)

  3. 2012

    Loggers beat spot checks

    A data logger is a small electronic recorder that stores a temperature reading at set intervals. The US National Institute of Standards and Technology (NIST) placed many sensors inside four refrigerator models of the kinds used to store vaccines. Three held 2 to 8 °C, but the dormitory-style model drifted and had large temperature differences inside, and NIST called it "not suitable for vaccine storage." NIST recommended continuous logging over thermometer checks by hand. A 2020 analysis by the US Centers for Disease Control and Prevention (CDC) of logger records from 320 vaccine providers found purpose-built refrigerators in range for 99.9% of their running time, against 98.9% for household refrigerator-freezer units.

    LessonA hand reading records one moment. NIST wrote that manual checks make it "impossible to know" whether the temperature left its range, an event called an excursion, "when no one was around.".

    nist.govpmc.ncbi.nlm.nih.gov

    Credit

    Michal Chojnacky and Gregory Strouse (NIST); CDC

  4. 2013

    Medicine stores get mapped

    Temperature mapping means measuring many points in a room or vehicle to find its warmest and coldest spots. The EU's Good Distribution Practice guidelines of 5 November 2013 say a mapping exercise should be carried out on a medicine storage area before use, and that the permanent monitors should then be placed where the mapping found the extremes. For temperature-controlled vehicles the guidelines ask for calibrated monitoring equipment and mapping that takes account of the seasons. If a customer asks, the distributor should supply information showing that the products stayed within their storage conditions. The guidelines replaced a 1994 text and a version issued in March 2013.

    eur-lex.europa.eu

    Credit

    European Commission

  5. 2015

    India wires vaccine stores

    India's health ministry rolled out the Electronic Vaccine Intelligence Network (eVIN) in 12 states in 2015. Staff record vaccine stock on a phone app, and temperature loggers send the storage temperature of each vaccine store and cold chain point, a health facility that stores vaccines, to a central server that alerts staff. India's immunization program runs through about 27,000 such points. An assessment written by ministry staff and partners reported that facilities with a stock-out of any vaccine fell from 37.8% to 26.3%. Researchers who interviewed staff at 40 cold chain points in Indore district in 2020 and 2021 heard that temperature monitoring had become continuous and that waste had fallen.

    LessonA monitoring network depends on the people and connections around it. The Indore staff named staff shortages, unreliable internet, device malfunctions and records kept twice, on paper and on screen, as its limits.

    pmc.ncbi.nlm.nih.govpmc.ncbi.nlm.nih.govebi.ac.uk

    Credit

    India's Ministry of Health and Family Welfare; United Nations Development Programme

  6. 2016

    Truckers must show temperatures

    The US Food and Drug Administration (FDA) published its rule on the sanitary transportation of food in April 2016. It covers shippers, loaders, carriers and receivers who move food by road or rail in the United States. For food that needs temperature control for safety, the shipper must tell the carrier in writing what temperature the load needs, and the carrier must, if asked, show that it kept that temperature.

    LessonThe rule does not require a recorder. It accepts "any appropriate means agreeable to the carrier and shipper," such as air temperature measured at loading and unloading, and it does not cover transport by ship or air.

    fda.govlaw.cornell.edu

    Credit

    US Food and Drug Administration

  7. 2017

    Containers report from sea

    A reefer is a refrigerated shipping container. Maersk Line fitted a GPS unit, a modem and a SIM card to all 270,000 of its reefers. From 24 July 2017 its customers could see each container's location, temperature, humidity and power status during the voyage, relayed by satellite transmitters on 400 ships. Maersk said that in the first six months of 2017 the system flagged more than 4,500 wrong temperature settings, 200 of them severe enough that the cargo would have been lost. The figures are Maersk's, as reported by The Maritime Executive.

    maritime-executive.com

    Credit

    Maersk Line

Watch for

  1. US food tracing by lot

    FDA's Food Traceability Rule requires firms that make, pack or hold foods on its Food Traceability List to keep records of set events, among them cooling, shipping and receiving, tied to a lot code, and to give them to FDA within 24 hours of a request. The original compliance date was 20 January 2026. In August 2025 FDA proposed moving it to 20 July 2028, and Congress then directed FDA not to enforce the rule before that date. In October 2026 FDA also published a draft policy of not enforcing it against certain small shops and restaurants.

    Achieved whenThe rule is being enforced and FDA reports a food traced from these records within 24 hours of asking.

    fda.gov

    Claimed by

    FDA, August 2025

  2. Battery-free tags on pallets

    Walmart is fitting pallets with Bluetooth sensors from Wiliot that have no battery and draw their power from radio waves and other energy around them. The sensors report temperature, location, humidity and how long a pallet has waited. Retail TouchPoints reported on 2 October 2025 that they were in use at 500 stores, with a plan to cover 4,600 stores and 40 distribution centers and to reach 90 million sensors by the end of 2026.

    Achieved whenWalmart or an outside auditor reports how many sensors are in use and how their temperature readings compare with a reference logger.

    retailtouchpoints.comtalkbusiness.net

    Claimed by

    Walmart and Wiliot, October 2025

  3. Agents that close excursions

    A software agent is a program that takes steps by itself toward a goal, using an AI model to choose each step. PAXAFE, a cold-chain software firm, says most products in its field, its own included, stop at answering questions about a shipment, and that it is building an agent that resolves an excursion before a quality manager hears of it. FourKites says its agent resolves 75% of exceptions without a person, and project44 markets 57 agents for freight tasks. MarketScale, which reported the claims, noted that neither the FourKites page nor the project44 page walks through one exception from detection to closure with no person involved.

    Achieved whenA shipper or an auditor publishes temperature excursions closed without a person, with the number of wrong calls.

    marketscale.com

    Claimed by

    PAXAFE, FourKites and project44, as reported by MarketScale, October 2026

Open

  1. 01

    Score excursion calls openly

    A public test for software that reads a temperature logger file and makes the call a quality reviewer makes: release the goods, hold them for a person, or reject them. The test set is built from real logger files given by clinics and pharmacies, with names removed. Each file is paired with the product's allowed range and its stated allowance for time out of range, and two qualified reviewers label it before any software sees it. The result is a score, not a release procedure, and no site changes how it handles stock.

    The brief
    Credit · unclaimed
  2. 02

    Bench-test cheap loggers

    An independent, public accuracy test of the low-cost Bluetooth and USB temperature loggers that anyone can buy for a refrigerator or freezer. Each model is checked against a calibrated reference thermometer in an ice-water bath, in a refrigerator and in a freezer, and again after 90 days of use.

    The brief
    Credit · unclaimed

Open 01 · the brief

Score excursion calls openly

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public test for software that reads a temperature logger file and makes the call a quality reviewer makes: release the goods, hold them for a person, or reject them. The test set is built from real logger files given by clinics and pharmacies, with names removed. Each file is paired with the product's allowed range and its stated allowance for time out of range, and two qualified reviewers label it before any software sees it. The result is a score, not a release procedure, and no site changes how it handles stock.

Why it is still open

The open tools and datasets found on GitHub and Hugging Face in November 2026 run on simulated shipments. One engine's own page says "Simulated data," and one dataset calls itself synthetic. Vendors claim agents that resolve exceptions, but MarketScale noted that neither of the two vendor pages it examined walks one case from detection to closure. CDC has analyzed logger records from 320 US vaccine providers, but no public, labeled set of such files turned up.

github.comgithub.commarketscale.com

Built with what exists

Logger exports in the makers' file formats; the Varo Foundation's open parser for Berlinger Fridge-tag files; a rule-based baseline such as the open cold-chain-excursion-engine; a language model such as Claude Fable 5.2 (see the Note "Three working devices"); a model that returns probabilities for fixed answers, such as Gemini Decision 1 (see the Note "A thousand questions, one pass"); a reviewer model that flags doubtful calls for a person (see the Note "Seven more flagged").

github.com

  1. First step

    Ask three sites for one month of logger exports each, strip identifying details, and have two reviewers label the first 20 files separately to see how often they agree.

  2. Done looks like

    300 real files from at least 10 sites, each labeled the same way by two reviewers, published with the scoring code. For each system tested: the share of calls that match the reviewers, with wrong "release" calls counted separately, beside the same figures for the rule baseline and for a third human reviewer.

Open 02 · the brief

Bench-test cheap loggers

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An independent, public accuracy test of the low-cost Bluetooth and USB temperature loggers that anyone can buy for a refrigerator or freezer. Each model is checked against a calibrated reference thermometer in an ice-water bath, in a refrigerator and in a freezer, and again after 90 days of use.

Why it is still open

NIST has bench-tested the loggers sold for vaccine storage: seven models in a 2012 report, and 40 devices of eight models, priced from $100 to $200, followed for two years from 2019 to 2021. The cheaper loggers sold to the public have had no such test, and the accuracy figures on offer are the makers' own. Govee's comparison of its sensor with a rival's names Govee the winner on accuracy. Searches of the web and of Europe PMC in November 2026 found retailer and affiliate reviews but no independent side-by-side test of these loggers in cold storage.

nist.govnvlpubs.nist.govus.govee.com

Built with what exists

A reference thermometer with a calibration certificate; a stirred bath of crushed ice and water, which sits at 0 °C; a household refrigerator and freezer; three units each of ten logger models; a spreadsheet or a Python notebook.

  1. First step

    Buy three models, borrow a calibrated reference thermometer, and run a 24-hour comparison in an ice bath and a refrigerator.

  2. Done looks like

    A published table for 10 models, three units each: error at 0 °C, near 5 °C and near −18 °C, the spread between units of one model, drift after 90 days, and how long each takes to register a door left open. The raw readings are public, and a second person repeats the ice-bath check on three models and gets the same error to within 0.2 °C.