BRENNEN

Industries / Transport and vehicles / Warehousing and distribution / Cold-chain logistics

Refrigerated trucks and containers

This is the work of building and running the insulated vehicles and boxes that carry cold goods by road, rail, sea and air, together with the cooling units fitted to them.

7

Milestones achieved, from 1867 to 2025.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1867

    Ice cools a rail car

    J. B. Sutherland of Detroit patented an "Improved Refrigerator-Car" on 26 November 1867: a car with double walls, an ice chest at each end, room for about 800 pounds (360 kg) of ice, and flaps placed so that air kept moving over the ice and through the load. In the winter of 1877 Gustavus Swift, a Chicago cattle dealer, sent a trial carload of dressed beef (carcasses butchered before shipping, in place of live cattle), then paid an engineer to perfect an ice-cooled car and set up icing stations on the routes east.

    LessonThe big railroads earned more from hauling live cattle and charged high rates for dressed meat, so Swift sent his cars over the Grand Trunk Railway through Canada; the car paid only once it had its own ice supply and a willing carrier.

    patents.google.comencyclopedia.com

    Credit

    J. B. Sutherland (patent); Gustavus Swift (commercial use)

  2. 1939

    A refrigerator on the truck

    Joseph Numero and Frederick McKinley Jones of Minneapolis applied on 16 November 1939 for a patent on a self-contained cooling unit, driven by its own engine, that bolted under the floor of a truck or rail car and could be taken off again. It was granted on 1 December 1942 as US Patent 2,303,857 and assigned to the U.S. Thermo Control Company. The National Inventors Hall of Fame says Jones "invented the first successful system for mobile refrigeration", which replaced ice and salt, and that the company, Thermo King, supplied refrigerated trucks that carried food to soldiers in the Second World War.

    patents.google.cominvent.org

    Credit

    Frederick McKinley Jones and Joseph Numero, U.S. Thermo Control Company (later Thermo King)

  3. 1970

    One standard for cold bodies

    The Agreement on the International Carriage of Perishable Foodstuffs and on the Special Equipment to be Used for such Carriage, known as ATP, was concluded in Geneva on 1 September 1970 and came into force on 21 November 1976. It grades an insulated body by its K coefficient, the measured rate at which heat leaks through the walls: no more than 0.7 watts per square meter per °C for "normally insulated" equipment, with a tighter class for "heavily insulated" bodies. It also sorts cooling units by the temperature they can hold, down to −20 °C for class C, and each country accepts the others' certificates. The UN Treaty Collection lists 52 parties, among them Morocco, Kazakhstan and Saudi Arabia; the United States joined in 1983 but declared that the agreement does not apply to carriage inside the United States.

    treaties.un.orgtreaties.un.org

    Credit

    member states of the UN Economic Commission for Europe

  4. 1970s

    Cold boxes carry their units

    The first refrigerated shipping containers, dated to 1956 by a 2026 review from Wageningen University, were insulated boxes with portholes that took cold air from ducts on the ship. In the 1970s "integral" containers arrived, with the refrigeration unit built into the box and run from a power plug, and the review says every reefer (refrigerated) container is now of this type. Maersk's history credits Sea-Land with the first generation of reefer containers in the 1960s and with integral ones from the early 1970s. By 2019, on Drewry figures quoted in the review, about 1.6 million reefer containers carried 80% of seaborne refrigerated cargo and specialized reefer ships the other 20%.

    LessonMaersk fitted its 1975 container ships with only ten reefer plugs each because forecasts said the plugs would be used 20% of the time; by 1986 its ships averaged 160.

    edepot.wur.nlmaersk.com

    Credit

    Sea-Land, by Maersk's account; the review is by L. J. S. Lukasse and colleagues at Wageningen University and Research

  5. 2000s

    Containers that slow ripening

    Controlled atmosphere (CA) lowers the oxygen and raises the carbon dioxide inside a container so that fruit breathes more slowly and keeps longer. The Wageningen review says CA has been available in reefer containers since around 2000, that all four makers of container refrigeration units now offer it, and that about 15% of the world fleet has it. It adds that moving fruit, vegetables and flowers from aircraft to ships often depends on CA to make up for the longer voyage.

    edepot.wur.nl

    Credit

    Carrier Transicold, Daikin, Thermo King and Maersk Container Industry (Star Cool), the four makers the review names

  6. 2021

    Insurers count the causes

    The transport insurer TT Club reported in November 2021 that about 35% of its 2020 incidents with temperature-controlled cargo came from clerical and communication errors, such as a set point (the temperature the unit is told to hold) passed on wrongly. Data it reviewed with the analytics firm ReeferPulse showed short temperature breaches, from power cuts or changes of vehicle, in up to 14% of cool shipments. The Swedish Club, a ship insurer, studied about 100 reefer container claims from 2017 to 2021: 69% arose during the voyage, and in 2021 the most common cause was temperature variation, at 65%.

    LessonA sound machine holding the wrong temperature still loses the load, so instructions need the same checking as equipment.

    ttclub.comiims.org.uk

    Credit

    TT Club; The Swedish Club

  7. 2025

    California drops a mandate

    In February 2022 the California Air Resources Board (CARB) amended its rule on transport refrigeration units (TRUs), the diesel-driven coolers on trucks and trailers, to make fleets turn over at least 15% of their truck units to zero-emission models by 31 December 2023 and each year after. The rule needed authorization from the US Environmental Protection Agency (EPA). EPA authorized the rest of the amendments on 3 January 2025 but did not act on the turnover requirement, and CARB withdrew that part of its request on 13 January 2025. Trucking associations had told EPA that fleets "are not able to meet the compliance requirements" because the units were not available or were still in pre-production, as reported by Heavy Duty Trucking.

    LessonA turnover date set before fleets could buy the equipment did not hold.

    epa.govpublic-inspection.federalregister.govtruckinginfo.com

    Credit

    California Air Resources Board; US Environmental Protection Agency

Watch for

  1. Solar and battery trailer units

    Sunswap, a maker in Leatherhead, England, sells a trailer refrigeration unit that runs on batteries and roof solar panels with no diesel engine. TIP Group, which leases trailers, said in July 2026 that more than a year of UK trials had delivered "100% uptime" with no unplanned refrigeration downtime, and Sunswap says operators cut refrigeration running costs by up to 81%. In April 2026 Sunswap said its units were in commercial use for Walmart Chile on routes between Santiago, La Serena and Concepción. Neither report gives the number of units or measured energy use.

    Achieved whenA fleet or an outside tester publishes a year of measured energy use and load temperatures for a stated number of units, beside diesel units on the same routes.

    fleetowner.comfleetowner.com

    Claimed by

    Sunswap and TIP Group, July 2026

  2. California's next unit rule

    After withdrawing its zero-emission requirement for truck units, CARB said it is working on a new rule "aimed at increasing the use of zero-emission technology across all TRU categories (including truck TRUs)", and that the specifics and timing "have not been determined", in guidance quoted by Heavy Duty Trucking. CARB's own bulletin of 11 June 2025 points to that guidance.

    Achieved whenCARB adopts a rule with dates, EPA authorizes it, and fleets report zero-emission units in service under it.

    truckinginfo.comcontent.govdelivery.com

    Claimed by

    California Air Resources Board, June 2025

Open

  1. 01

    Public file of lost loads

    An open, case-by-case table of refrigerated cargo losses taken from public court rulings. Each row gives the cargo, the mode of transport, the temperature ordered and the temperature used, the cause the court found (wrong set point, unit breakdown, power off, cargo loaded warm, delay), and the sum claimed, with a link to the ruling.

    The brief
    Credit · unclaimed
  2. 02

    Photo check of reefer loading

    A public test of whether a vision-language model, an AI model that reads images and text together, can look at photos of a loaded refrigerated trailer or container, taken from the open doors, and flag loads that block the cold air: cargo stacked too high, pushed against the doors, or covering the air return. The photos come from a parked box with its unit switched off at a cooperating cold store, or from a scale model. Nothing is driven.

    The brief
    Credit · unclaimed

Open 01 · the brief

Public file of lost loads

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open, case-by-case table of refrigerated cargo losses taken from public court rulings. Each row gives the cargo, the mode of transport, the temperature ordered and the temperature used, the cause the court found (wrong set point, unit breakdown, power off, cargo loaded warm, delay), and the sum claimed, with a link to the ruling.

Why it is still open

Insurers publish shares, not cases. TT Club gave one figure for 2020 and the Swedish Club analyzed about 100 reefer container claims. A 2019 paper by Magdalena Klopott sorted 1,816 claims and survey reports held by a surveying company, from 2015 to 2018, into five groups of causes and put human error behind about half of the damage; its abstract reports shares, not a case file. Searches for a public case-level dataset, on the web and on GitHub, found none.

ttclub.comjournals.ue.wroc.pl

Built with what exists

CourtListener, the Free Law Project's searchable archive of US court opinions, and its API; published English admiralty judgments; a small, low-cost model for pulling fields out of long rulings, such as Muse Ember (see the Note "The jobs agents repeat"); a fixed-answer model such as Gemini Decision 1 to give each case one cause from a set list (see the Note "A thousand questions, one pass"); a spreadsheet and a second human coder.

wiki.free.law

  1. First step

    Search CourtListener for opinions containing "reefer" and "set point", read the first 20 and draft the list of causes.

  2. Done looks like

    300 rulings coded and published. Two people code the same 100 independently and agree on the cause in at least 85 of them, and the model's agreement with them is reported beside that. The cause shares are set next to TT Club's and the Swedish Club's.

Open 02 · the brief

Photo check of reefer loading

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public test of whether a vision-language model, an AI model that reads images and text together, can look at photos of a loaded refrigerated trailer or container, taken from the open doors, and flag loads that block the cold air: cargo stacked too high, pushed against the doors, or covering the air return. The photos come from a parked box with its unit switched off at a cooperating cold store, or from a scale model. Nothing is driven.

Why it is still open

Climate-chamber tests reported by Wageningen University found that in a 40-foot container stuffed with 21 pallets, too little space between the last pallet and the door restricted airflow, and cargo temperatures differed by 4 to 7 °C. Carrier holds a US patent, granted on 3 June 2025, on using images of the load to estimate airflow and the chance of damage, but searches turned up no public photo set and no published accuracy figures.

edepot.wur.nlpatents.google.com

Built with what exists

A phone camera; a vision-language model such as Claude Fable 5.2 (see the Note "Three working devices"); a 1:10 scale box with printed cartons for staging faults safely; the loading rules in a unit maker's or shipping line's stowage guide; a spreadsheet answer key.

  1. First step

    Build the scale box, stage 30 loads with ten planted faults, photograph them and run one model.

  2. Done looks like