Industries / Industrial equipment and services / Industrial machinery / Valves
Actuators
An actuator is the motor, piston or spring unit fixed to a valve that opens and shuts it on command, so that nobody has to turn a handwheel.
4
Milestones achieved, from 1929 to 2022.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1929
A motor that stops itself
Payne Dean, an inventor who had come to the United States from England, received a US patent for a machine that senses the torque (twisting force) it puts out and stops before it passes a set limit; Flowserve's timeline dates the patent to 1929. Philadelphia Gear Works bought the patent in the 1930s and sold the device as Limitorque. Flowserve, which owns the brand today, says all heavy-duty electric actuators now limit torque in some way, so that a jammed valve is not wrecked, and Machine Design reported in 2004 that Limitorque SMB actuators were in every US nuclear power plant.
Credit
Payne Dean; Philadelphia Gear Works
1992
Set up with covers on
Rotork, based in Bath, England, sold its first electric actuator, the 100A, in 1957. Its IQ range of 1992 could be commissioned, that is, set to its valve's end positions and torque limits, without removing any electrical cover, so the work could be done in the wet or in hazardous areas where flammable gas may be present. Flowserve's Limitorque MX of 1997 is also sold as non-intrusive, and the MX adds an absolute encoder that keeps the valve position without a backup battery.
Credit
Rotork
2010
Safety ratings from outside
IEC 61508, the international standard for electrical and programmable systems that carry out safety functions, came out in its second edition on 30 April 2010. Under it, independent certifiers grade parts by safety integrity level (SIL), a measure of how reliably a safety function must work. The certifier exida rates Flowserve's Limitorque MX electric actuator as capable of use up to SIL 3, and TÜV certifies IMI's SHP-SIS positioner to IEC 61508:2010 up to SIL 3.
Credit
IEC; exida; TÜV
2022
Valves that close themselves
After the 2010 San Bruno gas line rupture in California, crews took 95 minutes to isolate the line, by the account of PHMSA, the US pipeline safety regulator. PHMSA's rule of 8 April 2022 requires most new and entirely replaced onshore gas transmission, gas gathering and hazardous liquid lines of 6 inches or more to have rupture-mitigation valves, which close automatically or by remote control, and to isolate a rupture within 30 minutes of identifying it.
Lessona valve that a crew must drive to closes too late in a rupture.
Credit
PHMSA, after recommendations from the NTSB
Watch for
Electric with a spring return
Spring-return actuators, such as single-acting pneumatic ones that open on air and close on a spring, are the usual way to send a valve to a set position when power fails, and Valmet says they can be large and heavy. Valmet says its Valvcon Quarterback QB-series electric quarter-turn actuator, launched on 23 January 2026, has internal spring packs that release on loss of power and drive the valve to a fail position that can be reversed in the field, in a design its product manager calls lighter than comparable products.
Achieved whenan outside test or a user's report gives the spring stroke time, the number of cycles survived and the weight against comparable spring-return actuators.
Claimed by
Valmet, January 2026
Faster strokes for safety valves
IMI says its SHP-SIS positioner, the device that turns a control signal into air pressure on the actuator, gives "ultra-fast stroking times" through a patented algorithm and a high air output, and has partial stroke testing built in: the safety valve is moved a short way and back while the plant runs, to show it is not stuck. The SIL 3 rating is TÜV's; the speed claim is IMI's own, and the announcement gives no stroke times.
Achieved whenan outside party publishes measured stroke times for the same valve and actuator with the SHP-SIS and with a conventional positioner.
Claimed by
IMI, December 2025
Open
01
An open actuator controller
Open firmware and a reference circuit board for a small electric quarter-turn actuator. The board drives a 24 V DC gear motor, reads valve position from a magnetic angle sensor, estimates torque from motor current, stops at a set torque, runs a partial stroke test on command, and logs a signature (torque against position) for every stroke, all published under an open license.
The briefCredit · unclaimed02
Nameplate torque, checked
A public bench test of low-cost electric quarter-turn actuators, the 24 V units sold online for small ball valves, measuring stall torque, running torque, stroke time and endurance against what each seller claims.
The briefCredit · unclaimed
Open 01 · the brief
An open actuator controller
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
Open firmware and a reference circuit board for a small electric quarter-turn actuator. The board drives a 24 V DC gear motor, reads valve position from a magnetic angle sensor, estimates torque from motor current, stops at a set torque, runs a partial stroke test on command, and logs a signature (torque against position) for every stroke, all published under an open license.
Why it is still open
Torque limiting has been standard since Limitorque, and makers now sell actuators with built-in self-tests that certifiers rate for safety duty, but all of it is closed product firmware. A GitHub search of repository names and descriptions in November 2026 for "valve positioner", "valve actuator firmware", "electric valve actuator" and "partial stroke test" found home radiator valve projects and no open firmware for an industrial-style actuator or positioner.
Built with what exists
A motor-control chip such as Renesas's RZ/T2N (see the Note "Four axes, one chip") or a common STM32 microcontroller; a small gallium nitride motor driver such as ST's (see the Note "A half-bridge in 6.5 by 5 mm"); a magnetic angle sensor such as the AS5048; a 24 V gear motor and a 1-inch ball valve; a reaction torque sensor to calibrate against. A chip that both drives the motor and runs a wear model, such as the one in the Note "Maintenance inside the joint", could host the signature analysis.
First step
Fit a torque sensor between a cheap 24 V quarter-turn actuator and a ball valve, stall it 20 times, and log motor current against measured torque to see how well current predicts torque.
Done looks like
Code, schematics and logs published; 10,000 open-and-close cycles on a dry bench valve with no missed end stop; in 100 forced stalls, the trip torque falls within 10% of the reference torque sensor's reading every time.
Open 02 · the brief
Nameplate torque, checked
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public bench test of low-cost electric quarter-turn actuators, the 24 V units sold online for small ball valves, measuring stall torque, running torque, stroke time and endurance against what each seller claims.
Why it is still open
Cycle life and torque ratings come from the makers' own tests. Asahi/America wrote in March 2026 that an actuator's cycle life "is not fixed" and varies greatly with operating conditions, and advises choosing an actuator with about 25% more torque than the valve needs. Searches in November 2026 found no published independent test of these actuators against their ratings.
Built with what exists
A brake rig with a rotary torque sensor and a disc brake or magnetic particle brake; a bench power supply with current logging; an Arduino or Raspberry Pi to cycle the actuators and record each stroke; dry ball valves for endurance runs. Everything runs at 24 V with no fluid under pressure.
First step
Build the brake rig and measure the stall torque of three units of one popular model.
Done looks like
At least 10 models, 3 units of each, tested for stall torque against the rating, with 2 units of each run for 20,000 cycles; a published table giving each model's measured torque as a share of its rating and the cycle at which any unit failed.