Control valves

A control valve sits partly open by just the right amount, moved all the time by a control system, so that a pressure, level, temperature or flow stays where it should.

6

Milestones achieved, from 1880 to 2011.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1880

    A governor holds the pressure

    During a fire in Marshalltown, Iowa, William Fisher, who worked at the town's water works, throttled its steam-driven pumps by hand all night to keep pressure steady in the water mains. He then designed the Type 1 constant pressure pump governor, a valve that set the pumps' speed from the pressure in the pipes, and began making it in 1880, with a patent in September 1884. Fisher's company became one of the oldest makers of control valves and regulators, now Emerson's Fisher brand, and its company history says the Type 1 remains in its product line almost unchanged.

    power-eng.comfundinguniverse.com

    Credit

    William Fisher

  2. 1944

    One number for capacity

    The flow coefficient Cv is the number of US gallons per minute of water at 60°F that pass through a valve with a pressure drop of 1 psi, so a valve rated Cv 12 passes 12 gallons a minute at that drop. Masoneilan says it introduced Cv in 1944 and that it quickly became the universal measure of valve capacity; the ISA and IEC standards now recognize both Cv and its metric twin Kv.

    LessonMasoneilan's handbook says most sizing errors come from wrong guesses about flowing conditions, and that stacking "safety factors" leaves valves so oversized that they give trouble.

    dam.bakerhughes.comisa.org

    Credit

    Masoneilan (now part of Baker Hughes), by its own account

  3. 1963

    A factor for choked flow

    Liquid speeds up and its pressure falls as it squeezes through a valve, then partly recovers downstream. Hans D. Baumann's paper "The Introduction of a Critical Flow Factor for Valve Sizing" (ISA Transactions, April 1963) gave a factor, now called FL, the liquid pressure recovery factor, that predicts the flow at which a valve chokes; FL is part of today's ISA and IEC sizing equations. ISA's recommended practice RP75.23 of 1995 added a sigma index for the stages of cavitation, in which vapor bubbles form at the low-pressure point and collapse against the metal.

    dam.bakerhughes.com

    Credit

    Hans D. Baumann; ISA

  4. 1993

    Sticking valves found out

    Papers published in 1993 by W. L. Bialkowski (Pulp and Paper Canada) and D. B. Ender (Control Engineering) argued that many control loops in process plants performed badly and cost production and quality, and Bialkowski named stiction, static friction that holds a valve stem until force builds and then lets it jump, as one cause of loops that keep oscillating. Tore Hägglund of Lund University published an automatic oscillation detector in 1995. ABB built it into its ECA400 and ECA600 controllers, which stop self-tuning when they see an oscillation so as not to detune a loop with a sticking valve, and in a Honeywell control system at the AssiDomän Frövi carton board mill in Sweden it watched over 91% of the control loops by 2002.

    Lessona badly behaved loop is often a valve problem, not a tuning problem, and retuning hides it.

    skoge.folk.ntnu.no

    Credit

    W. L. Bialkowski; D. B. Ender; Tore Hägglund; ABB

  5. 1994

    A computer on the valve

    Fisher's FIELDVUE digital valve controller, introduced in 1994, replaced the electronic and electro-pneumatic positioners on control valves with a microprocessor that runs on the current of the control signal's own wiring loop and reports how the valve moves, so that plants can watch valve health online and plan repairs. Emerson's Danny Nelson calls it the first communicating, loop-powered digital positioner. Emerson had sold more than 1 million by 2010 and 3 million by October 2022, by its own count reported in the trade press.

    controlglobal.comcontrolglobal.com

    Credit

    Fisher Controls (Emerson)

  6. 2011

    Sizing by one standard

    IEC 60534-2-1, the international standard for sizing control valves, came out in its second edition on 30 March 2011, with equations for liquids and gases and corrections for flow that is not fully turbulent. Baker Hughes's Masoneilan sizing handbook builds on the same equations as the US standard ANSI/ISA S75.01.01, and the open-source Python library fluids, by Caleb Bell, codes them and checks its results against the standard's worked examples.

    webstore.iec.chdam.bakerhughes.comgithub.com

    Credit

    IEC subcommittee 65B; ISA 75 committee

Watch for

  1. Diagnosis without a specialist

    Emerson says its free Fisher ValveLink Pro software, released on 29 January 2026 for its FIELDVUE DVC7K controllers, lets instrument technicians "reliably identify changes in valve performance over time, without the need for specialist expertise", with alerts and recommended actions and new offline tests such as step response tests.

    Achieved whena user or outside party publishes cases in which technicians' findings from the software were checked against a specialist's review or a teardown.

    emerson.com

    Claimed by

    Emerson, January 2026

  2. Positioners that use less air

    Rotork says its RTP-4000 positioners, launched in October 2025 with the RTP-4400, combine diagnostics from built-in pressure sensors with "optimised supply air consumption" that lowers running costs. The announcement gives no figures.

    Achieved whenan outside party measures the RTP-4400's steady-state air use against other positioners on the same valve.

    watermagazine.co.uk

    Claimed by

    Rotork, October 2025

Open

  1. 01

    Test cases for sizing tools

    A public set of at least 100 control valve sizing cases, liquids and gases, choked and not choked, with and without pipe reducers and at low Reynolds numbers (slow or thick flow that is not fully turbulent), each with a reference answer worked out separately by two people. Then a scoreboard on which free maker tools, open calculators and general AI models are all run on the same cases.

    The brief
    Credit · unclaimed
  2. 02

    Catalog Cv, retested in public

    A low-pressure water test bench, laid out like the ISA and IEC test manifold, that measures the Cv of small valves (half an inch to 2 inches) at several openings, and a published comparison with each maker's catalog figure.

    The brief
    Credit · unclaimed

Open 01 · the brief

Test cases for sizing tools

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public set of at least 100 control valve sizing cases, liquids and gases, choked and not choked, with and without pipe reducers and at low Reynolds numbers (slow or thick flow that is not fully turbulent), each with a reference answer worked out separately by two people. Then a scoreboard on which free maker tools, open calculators and general AI models are all run on the same cases.

Why it is still open

Sizing code is everywhere. Makers give away tools such as Valmet's Nelprof, a free web tool that also predicts noise and cavitation, and a GitHub search in November 2026 found at least ten repositories updated in 2025 or 2026 that claim IEC 60534 sizing. The fluids library checks itself against the standard's own examples, but the standard is sold, not free. PSE-Bench (Sukpancharoen and Srinophakun, 2026) scores AI models on 200 process engineering questions, none of them on valve sizing by its topic list, and no shared public test set was found that would let anyone check a new calculator or an AI model's answer.

github.comgithub.comvalmet.comgithub.com

Built with what exists

Worked examples from makers' public handbooks, such as Masoneilan's and Fisher's; the fluids library as one reference; free maker sizing tools; general AI chat models asked the same questions; a spreadsheet or a small Python harness that scores every answer.

  1. First step

    Copy the worked examples from the Masoneilan handbook into a table and reproduce them with the fluids library.

  2. Done looks like

    100 or more cases published with sources; every tool's required Cv reported for every case, with the share of cases within 5% of the reference and a list of the cases that tools get wrong.

Open 02 · the brief

Catalog Cv, retested in public

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A low-pressure water test bench, laid out like the ISA and IEC test manifold, that measures the Cv of small valves (half an inch to 2 inches) at several openings, and a published comparison with each maker's catalog figure.

Why it is still open

Marc Riveland, who chairs the ISA75.01 sizing working group, and Andrew Kinser of Emerson wrote in 2019 that published Cv values for nearly identical full-bore ball valves differ widely, because one maker counts only the losses in the valve and another tests the valve with the standard's lengths of straight pipe. Engineers at Bray International reported in 2023, from tests at the Utah Water Research Laboratory, that slack in the coupling, actuator and positioner left a valve up to 10.5 degrees from its reported position, enough to change the Cv measured part-open. Catalog figures for small valves are the makers' own, and searches in November 2026 found no public test that checks a range of them on one bench.

isa.orgvalve-world-americas.com

Built with what exists

A recirculating water loop with a small centrifugal pump and a tank; a magnetic or Coriolis flowmeter; a differential pressure transmitter with taps 2 pipe diameters upstream and 6 diameters downstream of the valve, as the ISA article describes; an angle sensor on the valve stem itself; a data logger; ball, globe and butterfly valves bought from distributors. Water at a few bar is safe for a student lab.

  1. First step

    Build the loop with straight pipe and no valve, and check that the flowmeter and pressure readings give the expected pipe friction loss.

  2. Done looks like

    At least 10 valves from at least 5 makers, each measured at 25%, 50%, 75% and 100% open with repeat runs; a table of measured against catalog Cv with the measurement uncertainty, and the bench drawings published so others can repeat it.