A circuit breaker is a switch that can open while current flows, even the very large current of a fault, and switchgear is the assembly of breakers, switches and conductors that connects, protects and isolates a line, a transformer or a plant.

6

Milestones achieved, from 1926 to 2024.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1926

    Vacuum switching works

    Oil circuit breakers of the time put out the arc that forms between opening contacts by boiling oil around it. At the California Institute of Technology, Royal Sorensen and Hallan Mendenhall instead opened circuits between metal contacts sealed in a high vacuum, and at a Southern California Edison substation one of their switches opened a short-circuit current of 926 amperes at 41,500 volts. In every recorded test the arc went out at the end of the first half cycle, but they wrote that a practical switch still needed vacuum-tight joints and a pump that did not depend on liquid air.

    Lessona better way to break current can be proven long before the factory methods to build it exist.

    worldradiohistory.com

    Credit

    Royal W. Sorensen and Hallan E. Mendenhall, California Institute of Technology

  2. 1956

    SF6 replaces oil

    Customers asked Westinghouse for a nonflammable substitute for the oil in high-power breakers, so its engineers tested gases known to insulate well and found that sulfur hexafluoride (SF6) was also unusually good at putting out arcs. The patent by H. J. Lingal, T. E. Browne and A. P. Strom was filed on 19 July 1951 and issued on 31 July 1956. Winthrop Leeds, who led the work, says SF6 went first into small switches, then into breakers that used a piston to blow the gas through the arc, and became an industry standard.

    ethw.org

    Credit

    H. J. Lingal, T. E. Browne Jr., Albert Strom and Winthrop Leeds (Westinghouse)

  3. 1967

    Vacuum tried at 132 kV

    A vacuum circuit breaker built by AEI went into service at 132 kV for Britain's Central Electricity Generating Board at West Ham, London, in 1967, and it and others stayed in service into the late 1990s, by the account of Leslie Falkingham of Vacuum Interrupters Ltd to the IEEE Switchgear Committee in 2008. A single vacuum interrupter of the 1960s could handle only 17.5 or 24 kV, so a transmission breaker needed many in series and a complex mechanism, and makers designed their interrupters for the far larger distribution market. By 2008 vacuum breakers were sold only up to 145 kV.

    Lessona design that works can still lose if its parts are made for a different market.

    ewh.ieee.org

    Credit

    AEI; Central Electricity Generating Board

  4. 2020

    Breakers for direct current

    Alternating current passes through zero 100 or 120 times a second, which gives a breaker a moment to put out the arc; direct current never does. ABB announced in November 2012 a hybrid breaker, fast mechanical switches joined to power electronics, that it said would interrupt in 5 milliseconds and called the world's first circuit breaker for high-voltage DC, though ENTSO-E, the association of European grid operators, describes older mechanical DC breakers built from air-blast breakers. ENTSO-E lists a 500 kV, 25 kA hybrid breaker as in operation on the Zhangbei DC grid in China since 2020, and rates such breakers in Europe at readiness level 6 of 9 at 525 kV, short of routine use.

    entsoe.eumb.cision.com

    Credit

    ABB (2012 design); State Grid Corporation of China (Zhangbei)

  5. 2023

    SF6-free at 420 kV

    A 2026 CIGRE paper by staff of the US utility Eversource Energy and the maker Hitachi Energy says the first modern SF6-free breaker became available in 2022 and was first energized in a grid in 2023, as a 420 kV dead-tank breaker (one whose interrupter sits inside a grounded metal tank) in the United States. After two years in service, the user and the maker report that it behaved much like an SF6 breaker, cleared a real fault on the grid, and kept stable gas quality.

    e-cigre.org

    Credit

    Eversource Energy (operator); Hitachi Energy (maker)

  6. 2024

    SF6 gets end dates

    Regulation (EU) 2024/573 bars putting into operation new switchgear that relies on fluorinated gases, in steps: up to 24 kV from 1 January 2026 and 24 to 52 kV from 2030, and, for gases with a global warming potential of 1 or more (a measure of heating effect, with CO2 as 1), high-voltage gear of 52 to 145 kV from 2028 and above 145 kV from 2032, by Siemens Energy's summary of the final text. From 2035 only reclaimed or recycled SF6 may be used for servicing, by the German Environment Agency's account. California's Air Resources Board had already amended its own rule, effective 1 January 2022, to stop the purchase of new SF6 gas-insulated equipment in steps from 1 January 2025 to 1 January 2033, by voltage and short-circuit rating. In October 2026 seven EU member states told the Council of the EU that the rule's exception for equipment with a lower life-cycle carbon footprint could not yet be used, because the Commission had adopted no method for measuring it, and that high-voltage switchgear took 24 to 30 months to deliver.

    assets.siemens-energy.comumweltbundesamt.deww2.arb.ca.govww2.arb.ca.govdata.consilium.europa.eu

    Credit

    European Parliament and Council of the EU; California Air Resources Board

Watch for

  1. Vacuum breakers at 420 kV

    Siemens Energy describes live-tank breakers (the interrupter is held up on insulators at line voltage) for 245 kV and 420 kV that switch in vacuum and insulate with clean air, a nitrogen and oxygen mix with a global warming potential of zero. It calls them the world's first greenhouse-gas-free breakers at these ratings, reports simulation and development tests, and plans pilot projects in France, Norway and Spain.

    Achieved whena pilot breaker is energized in a grid and the operator or an independent laboratory publishes test or service results.

    e-cigre.org

    Claimed by

    Siemens Energy (Mark Kuschel and co-authors), CIGRE Session paper, 2026

  2. Solid-state breakers for data centers

    A solid-state circuit breaker interrupts current with semiconductor switches and has no contacts to pull apart. Infineon and SolarEdge are developing one for the 800 V DC power that AI data centers are moving to, built on Infineon's silicon carbide JFET chips, and say such breakers are designed to clear faults within a few microseconds. Silicon carbide power chips are explained in the Note "More chips from a bigger disc".

    Achieved whena breaker is certified by an independent test laboratory and protects racks in a working data center, with interruption times published.

    semiconductor-today.com

    Claimed by

    Infineon Technologies and SolarEdge Technologies, September 2026

Open

  1. 01

    A public SF6-free product register

    An open table of every breaker and switchgear product sold without SF6, one row per rating, giving the maker, product, voltage, short-circuit current, the gas or vacuum it uses and that gas's global warming potential, the laboratory and certificate for its type tests where published, its first energization, and a link for each fact.

    The brief
    Credit · unclaimed
  2. 02

    Save the SF6 leak record

    A public table of the yearly SF6 leak rate, emissions divided by the gas held in equipment, for each US power company that reported to the US Environmental Protection Agency (EPA) from 2011 to 2024, with companies that stopped reporting marked and the raw reports archived so the record survives if reporting ends.

    The brief
    Credit · unclaimed

Open 01 · the brief

A public SF6-free product register

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open table of every breaker and switchgear product sold without SF6, one row per rating, giving the maker, product, voltage, short-circuit current, the gas or vacuum it uses and that gas's global warming potential, the laboratory and certificate for its type tests where published, its first energization, and a link for each fact.

Why it is still open

Under the EU rule a buyer may choose a fluorinated gas only when no bid offers a lower-warming alternative, so what exists at each rating decides what can be bought. The European Commission's last published assessment of alternatives, by voltage level, dates from 30 September 2020, before most high-voltage products were offered.

assets.siemens-energy.comclimate.ec.europa.eu

Built with what exists

Makers' product pages and catalogs; summaries of CIGRE papers on e-cigre.org; type-test certificates that makers publish; a language model that drafts each row and cites the sentence it came from (see the Note "Findings that cite notes"); a second person who checks every row.

  1. First step

    List the SF6-free products of three makers at 145 kV and above, with a source for each rating.

  2. Done looks like

    Every SF6-free product at 12 kV and above from at least ten makers, each rating with its medium and at least one source, a second checker agreeing on at least 95% of fields, published under an open license and updated every three months for a year.

Open 02 · the brief

Save the SF6 leak record

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of the yearly SF6 leak rate, emissions divided by the gas held in equipment, for each US power company that reported to the US Environmental Protection Agency (EPA) from 2011 to 2024, with companies that stopped reporting marked and the raw reports archived so the record survives if reporting ends.

Why it is still open

The EPA's own profile of the sector reports totals and one emission rate for the members of its voluntary partnership, not a rate for each company, and it notes that companies may stop reporting after several years of low emissions. In September 2025 the EPA proposed to end reporting for this sector, Subpart DD, after reporting year 2024, and it has since twice moved the deadline for 2025 reports, now to 10 March 2027, while it decides. Each company's report includes both its emissions and the nameplate capacity (the full gas charge) of its equipment, so the rate can be worked out.

19january2021snapshot.epa.govepa.govpublic-inspection.federalregister.govepa.gov

Built with what exists

The EPA's Greenhouse Gas Reporting Program data for Subpart DD, the part covering electric transmission and distribution equipment; Python with pandas; a public data archive such as Zenodo; a second person to rerun the code.

  1. First step

    Download one year of Subpart DD reports and work out the rate for ten utilities.

  2. Done looks like

    A rate for every company and year from 2011 to 2024, with sector totals matching the EPA's published totals to within 1%, the raw files deposited in a public archive, and code public so that a second person reproduces the table.