BRENNEN

Industries / Industrial equipment and services / IoT and industrial automation / SCADA integration

Connecting to business systems

This work links SCADA to the software that plans production, schedules maintenance and bills customers, and to other companies' control centres.

5

Milestones achieved, from 1989 to 2021.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1989

    A ladder of plant levels

    The Instrument Society of America (now ISA) published "A Reference Model for Computer Integrated Manufacturing (CIM)", prepared by a committee of the International Purdue Workshop on Industrial Computer Systems and edited by Theodore J. Williams. Its levels, from field devices at the bottom to business planning at the top, became the "Purdue model" that plants use to decide which networks may talk to which; NIST's 2023 guide to operational technology security still tells plants using it to block level 4 (business) devices from reaching levels 2, 1 or 0 directly.

    pera.netnvlpubs.nist.gov

    Credit

    Theodore J. Williams and the workshop's CIM Reference Model Committee

  2. 1994

    Control centres share live data

    Utilities used to swap real-time grid data with each other over in-house or proprietary protocols. A working group of utilities, vendors and EPRI (the Electric Power Research Institute), formed in 1991, wrote ICCP (Inter-Control Center Communications Protocol), and in late 1994 an EPRI demonstration passed live data between the control centres of the Western Area Power Administration in Loveland, Colorado, and Ohio Edison in Wadsworth, Ohio. The IEC adopted it as TASE.2, part of its IEC 60870-6 series, in 1997.

    oracle.comkoreascience.kr

    Credit

    The Utility Communications Specification working group, EPRI, Western Area Power Administration and Ohio Edison

  3. 2000

    Plant and business, one vocabulary

    ISA-95, "Enterprise-Control System Integration," was first published in 2000 to define the data passed between business systems such as planning software (level 4 of the Purdue model) and the systems that run production (level 3). The IEC published it internationally as IEC 62264-1 in 2003, and B2MML, a free set of XML formats for its messages whose development was led by Dave Emerson, "encouraged the adoption" of the standard, ISA says.

    isa.orgwebstore.iec.ch

    Credit

    ISA's ISA95 committee; IEC; the B2MML XML working group

  4. 2020

    Secure protocol, insecure setups

    OPC UA, the cross-platform successor to the OPC data standard, was built with encryption, message signing and certificates so that plant data can pass firewalls safely. Researchers at RWTH Aachen University and Fraunhofer FKIE scanned the whole IPv4 internet, found 1,114 reachable OPC UA systems, and reported missing access control, switched-off security or outdated cryptography on 92% of them, and several hundred devices sharing one certificate.

    LessonA protocol's security features protect nothing until someone turns them on and sets them up.

    arxiv.orgopcfoundation.org

    Credit

    Markus Dahlmanns, Martin Henze and colleagues

  5. 2021

    Europe's grid models, one format

    The Common Grid Model Exchange Standard (CGMES), ENTSO-E's profile of the IEC's Common Information Model (CIM), a standard way of describing grid equipment in data, became an IEC International Standard in 2021 as CGMES 3.0. European transmission system operators use it to exchange the common grid models that the EU network codes call for, and ENTSO-E, their association, tests the tools for interoperability every year.

    entsoe.euentsoe.eu

    Credit

    ENTSO-E; IEC Technical Committee 57

Watch for

  1. AI agents reach SCADA data

    Inductive Automation says Ignition 2027 includes Catalyst Agents, a module for building AI agents inside its Ignition SCADA software that also works as an MCP (Model Context Protocol) client and server, so outside AI agents can query Ignition and its own agents can call other tools; it set a public beta for November 2026 and general release for February 2027. AVEVA said in May 2026 that it would bring MCP integrations to its own systems.

    Achieved whenthe features ship and a user or outside tester publishes what the agents could read and change under set permissions on a working system.

    controleng.comdocs.inductiveautomation.comaveva.com

    Claimed by

    Inductive Automation, September 2026; AVEVA, May 2026

  2. AI maps data to models

    AVEVA says a "twin builder" in a CONNECT release planned for the first quarter of 2027 will apply "agentic AI to propose intelligent mappings that align existing data sources to a standard data model," filling an industrial knowledge graph of how assets relate.

    Achieved whenit ships and a user publishes what share of the proposed mappings engineers accepted unchanged.

    aveva.com

    Claimed by

    AVEVA, May 2026

Open

  1. 01

    Tag names matched, publicly scored

    A public test set of plant tag names (codes such as "21-FIC-1001.PV" that name each reading), with their descriptions and units, each matched by hand to the right piece of equipment in an asset hierarchy, and a scored comparison of the ways of matching them automatically, from string similarity to large language models that read the descriptions.

    The brief
    Credit · unclaimed
  2. 02

    Hidden instructions versus SCADA agents

    A repeatable test of AI agents connected to SCADA software through MCP servers, in which instructions are hidden in what the agent reads (an email, a PDF, a tag description, an alarm message) to see whether it changes a value or starts a pump that nobody asked it to. It runs on simulators and mock-ups only, never on live equipment.

    The brief
    Credit · unclaimed

Open 01 · the brief

Tag names matched, publicly scored

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public test set of plant tag names (codes such as "21-FIC-1001.PV" that name each reading), with their descriptions and units, each matched by hand to the right piece of equipment in an asset hierarchy, and a scored comparison of the ways of matching them automatically, from string similarity to large language models that read the descriptions.

Why it is still open

Matching is done by hand or by tools whose accuracy on other people's data is not public. Cognite's entity matching proposes a match only "when there are some similarities between the strings"; an ensemble of machine-learning models mapped 68% of tags correctly for a fleet of air separation units in 2024, which its authors called "too low for a fully automated process," on data that was not released.

docs.cognite.comapi.semanticscholar.org

Built with what exists

A tag export and asset register from a cooperating plant; a string-matching baseline in Python with the RapidFuzz library; large language models such as Claude, or Mistral Large 4, whose weights are free to download (covered in the Note "A trillion open parameters").

  1. First step

    Ask one university heating or water plant for its historian tag list and asset register, remove site names, and hand-match the first 500 tags.

  2. Done looks like

    At least 2,000 hand-matched tags from at least three plants, published with the code, and a table of the share matched correctly at a setting where at least 95% of accepted matches are right, set against the 68% reported in 2024.

Open 02 · the brief

Hidden instructions versus SCADA agents

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A repeatable test of AI agents connected to SCADA software through MCP servers, in which instructions are hidden in what the agent reads (an email, a PDF, a tag description, an alarm message) to see whether it changes a value or starts a pump that nobody asked it to. It runs on simulators and mock-ups only, never on live equipment.

Why it is still open

The public evidence is one researcher's demonstration in July 2025: a hidden, base64-encoded line in a PDF made Claude Sonnet 4 write a pump tag through an open-source MCP server for Siemens WinCC on a mock-up, after the engineer had clicked "always accept." The IndustriConnect benchmark of industrial MCP adapters (March 2026) ran 870 normal, fault, stress and recovery trials, not attacks.

veganmosfet.codeberg.pagearxiv.org

Built with what exists

Open-source MCP servers such as kukapay/opcua-mcp, which can write to OPC UA nodes, and WhiskeyHouse/ignition-mcp for Ignition 8.3 gateways; an OPC UA simulator such as the open-source open62541 library; AI hosts such as Claude Desktop. Guards that stop an agent that strays, such as NVIDIA's planned Sentry (covered in the Note "Stopped in milliseconds"), are the kind of control the test would score.

github.com

  1. First step

    Rebuild the 2025 WinCC demonstration against an OPC UA simulator through two other MCP servers and record whether the write happens.

  2. Done looks like

    At least 50 hidden-instruction cases run against at least four MCP servers, each with and without a confirmation prompt, and a public tally of unrequested writes for each combination.