BRENNEN

Industries / Industrial equipment and services / IoT and industrial automation / Process instrumentation

Level

This work makes the instruments that tell how full a tank, vessel or silo is, using floats, pressure at the bottom, radar or sound from the top, or a probe that reaches into the liquid.

4

Milestones achieved, from 1976 to 2016.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1976

    Radar on a tanker

    In the late 1960s Olle Edvardsson worked on radar altimeters for aircraft at a division of Saab in Sweden, while tanker owners struggled with mechanical tank gauges that needed frequent, risky maintenance; by his account, static electricity from washing the tanks of the new very large tankers caused a number of accidents. A tank gauge needed accuracy of a few hundredths of a percent, against a few percent for an altimeter. Emerson's history says a design project began in 1971, a first field trial went onto M/S Sea Scout at the Kockums yard in Malmö in 1973, and in 1976 the first mass-produced system, the SUM-21 Tank Radar, was installed on the Norwegian ship M/S Havdrott. Emerson bought Saab Marine Electronics in 2001 and renamed it Rosemount Tank Radar.

    emersonautomationexperts.comemerson.com

    Credit

    Olle Edvardsson and Saab Marine Electronics

  2. 1998

    Rules for gauges in trade

    The International Organization of Legal Metrology (OIML), the intergovernmental body that harmonizes the rules for instruments used in trade, issued Recommendation R 85 in 1998 for automatic level gauges on stationary storage tanks. Their readings are used with each tank's calibration table to determine the volume of liquid received, delivered or held. The 2008 edition, which replaced it, allows an error of ±1 mm in the laboratory before installation and ±4 mm once fitted, tested at no fewer than 10 levels rising and falling.

    oiml.orgoiml.org

    Credit

    OIML

  3. 2009

    One gauge, no backup

    On the night of 23 October 2009, while gasoline was being unloaded from the tanker Cape Bruny, Tank 409 at the Caribbean Petroleum Corporation (CAPECO) terminal in Bayamón, Puerto Rico, overflowed. The vapor cloud exploded, damaging 17 of the site's 48 tanks and about 300 homes and businesses up to 1.25 miles (2 km) away, and fires burned for almost 60 hours. The US Chemical Safety Board (CSB) found the tank gauges unreliable: the float-and-tape gauge or the side gauge on Tank 409 likely gave wrong levels, its transmitter to the office computer was not sending data that night, and operators often ignored the computer because the transmitters were so often out of service. The tanks had no independent high-level alarm and no automatic system to stop an overfill; the CSB noted that the API 2350 standard required such a system only at remotely operated sites.

    LessonA tank with one level instrument has no protection when it fails, so overfill protection needs a second, independent measurement that can stop the transfer.

    csb.gov

    Credit

    US Chemical Safety Board (investigation, final report October 2015)

  4. 2016

    Radar at 80 GHz

    VEGA Grieshaber, a German maker, launched the VEGAPULS 64 in March 2016 and calls it the world's first radar level sensor for liquids working at 80 GHz, about three times the 26 GHz then widely used, after a bulk-solids model in 2014. A higher frequency focuses the beam more tightly from the same size of antenna: by VEGA's figures the beam is 3° wide from an 80 mm antenna, so it passes beside fittings inside the tank and buildup on its walls that would send false echoes. Other makers now sell 80 GHz ranges, among them Endress+Hauser, which introduced its Micropilot FMR60B to FMR67B family in August 2024.

    automation.comvega.comfoodengineeringmag.com

    Credit

    VEGA Grieshaber

Watch for

  1. Radar that never needs recalibrating

    KROHNE says its OPTIWAVE 1530 and 1560 radar level transmitters, FMCW radars (they sweep their frequency and read distance from the difference between the sent and returned signal), give "drift-free, maintenance-free operation without the need for recalibration over the lifetime of the product," with a 4° beam and reliable readings on foamy or agitated liquids.

    Achieved whena user or laboratory outside KROHNE publishes several years of readings compared with hand dips or a reference gauge, or measured errors in foam.

    wateronline.com

    Claimed by

    KROHNE, September 2025

  2. Radar level on batteries

    Emerson says its Rosemount 3408 Wireless is the world's first native WirelessHART non-contacting radar level transmitter, sending readings by radio from a battery power module, with a slower update rate giving longer battery life; the release gives no battery-life figure.

    Achieved whena user outside Emerson reports a year or more in service with the battery life at a stated update rate and readings checked against another measurement.

    emerson.com

    Claimed by

    Emerson, October 2025

Open

  1. 01

    Level sensors in foam

    An open test column filled with water in which sensors of each main kind, 80 GHz radar, guided wave radar (a radar pulse sent down a rod or cable into the liquid), ultrasonic, and a pressure transmitter at the bottom, measure the same level while foam, stirring, condensation and a pipe inside the column are added one at a time, all compared against a reference reading.

    The brief
    Credit · unclaimed
  2. 02

    An open radar tank gauge

    An open design, with circuit files, firmware and processing code, for a radar level gauge built on a low-cost radar chip, and a published test of it against the OIML R 85 laboratory requirement: at least 10 levels rising and falling, each read within ±1 mm.

    The brief
    Credit · unclaimed

Open 01 · the brief

Level sensors in foam

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open test column filled with water in which sensors of each main kind, 80 GHz radar, guided wave radar (a radar pulse sent down a rod or cable into the liquid), ultrasonic, and a pressure transmitter at the bottom, measure the same level while foam, stirring, condensation and a pipe inside the column are added one at a time, all compared against a reference reading.

Why it is still open

Makers' advice is qualitative. VEGA writes that foam "absorbs signals" and that "even 80 GHz radar sensors with high dynamic range and the most sensitive of ultrasonic devices are no match for thick foam," and recommends guided wave radar for heavy foam, while KROHNE claims reliable readings on foamy liquids. The published work found is a 2017 computer model of foam at 6 and 26 GHz by Vlad Neagu of the Technical University of Cluj-Napoca, and a 2008 test of one radar in a simulated nuclear waste slurry for the Hanford site, which found that with the stirrer off the radar read the top of the foam instead of the liquid. No measured comparison of several technologies and makers was found.

vega.comosti.govapi.openalex.org

Built with what exists

A clear acrylic column about 2 m tall on a drained floor; loaned or used sensors such as a VEGA VEGAPULS 80 GHz radar, an Endress+Hauser Micropilot FMR6xB, a KROHNE OPTIWAVE, a guided wave radar, an ultrasonic sensor and a submersible pressure transmitter; a side sight tube with a steel tape and a camera as the reference; an aquarium air pump and washing-up liquid for foam; a paddle mixer; a 4–20 mA data logger and HART modem; Python.

  1. First step

    Build the column, fit one 80 GHz radar and one guided wave radar, and log both against the sight tube with 2 cm and then 10 cm of foam.

  2. Done looks like

    At least eight sensors from at least four makers, each read at 10 levels rising and falling (the pattern OIML R 85 uses) under five conditions: still water, 2 cm of foam, 10 cm of foam, stirring and condensation. The error against the reference and the count of lost echoes are published for every reading, with the raw data and the radars' echo curves.

Open 02 · the brief

An open radar tank gauge

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open design, with circuit files, firmware and processing code, for a radar level gauge built on a low-cost radar chip, and a published test of it against the OIML R 85 laboratory requirement: at least 10 levels rising and falling, each read within ±1 mm.

Why it is still open

Gauges that meet R 85 are closed commercial products. Texas Instruments says its radar chips can sense level "with sub 1mm precision," a maker's claim; its TIDEP-0091 tank-level reference design is about cutting power use. An open Python package from Ruhr University Bochum, mmwRanging, may give micron-scale accuracy in measuring distance with laboratory radars such as 2pi-Labs' 2piSENSE, by its authors' account, and a January 2026 field study of commercial radar sensors over water reached centimeter-scale precision. A GitHub search found no open radar tank gauge.

ti.comgithub.comarxiv.orgoiml.org

Built with what exists

A TI IWR1443 evaluation board, the chip family in TIDEP-0091, used indoors; the methods in mmwRanging; a flat metal plate on a linear rail with a digital scale reading to 0.01 mm for the dry test; a 2 m water standpipe with a calibrated laser distance sensor or tape as the wet reference; Python; KiCad for the board design.

  1. First step

    Mount the evaluation board above the metal plate on the rail and measure 10 positions over 1 m against the rail's scale.

  2. Done looks like