Industries / Industrial equipment and services / IoT and industrial automation / Process instrumentation
Flow
Flow work is making the meters that measure how much liquid, gas or steam moves through a pipe, from devices that read a pressure drop to meters that use magnetism, vibration or sound.
7
Milestones achieved, from 1888 to 2016.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1888
A meter for mill water
Clemens Herschel, hydraulic engineer for the Holyoke Water Power Company in Massachusetts from 1879 to 1889, devised the Venturi meter to measure how much water each mill on the town's power canals used. It works out the flow from the difference in pressure between the full pipe and a smooth narrowing in it. The American Society of Mechanical Engineers (ASME) says Herschel first tested the meter in 1886 and used it commercially in 1889; his US patent, number 381,373, was granted on 17 April 1888. He named it after Giovanni Battista Venturi, an 18th-century Italian scientist who studied flow through pipes.
Credit
Clemens Herschel, Holyoke Water Power Company
1930
Orifice meters get a standard
An orifice meter measures gas flow from the pressure drop across a plate with a hole in it, clamped in the pipe. After Thomas Weymouth published his orifice meter in an ASME paper in 1912, Foxboro, Metric Metal Works and Bailey Meter each built meters with their own coefficients, the factors that turn a pressure drop into a flow, and two makes used in series gave different answers. Tests planned with Howard Bean of the US National Bureau of Standards (NBS) from 1922 led to the American Gas Association's Report No. 1 in 1930, the first industry standard on orifice meters, according to a history published by Daniel Measurement and Control, an orifice meter maker. Its flange-tap coefficients rested on 303 data points taken at Ohio State University from 1929 to 1933 and served for about 60 years, until the 1990–92 revision of AGA Report No. 3 refit them to some 10,000 points from US and European laboratories; ISO 5167, the international standard, took up the new Reader-Harris/Gallagher equation in a 1998 amendment.
LessonMeters built to each maker's own coefficients disagreed, so buyers and sellers of gas needed one set of shared test data.
Credit
Thomas Weymouth; Howard Bean (NBS); the AGA's Gas Measurement Committee
1952
Magnetic meters for liquids
A magnetic flowmeter, or magmeter, puts a magnetic field across a pipe and measures the small voltage induced in a conducting liquid as it flows through, which rises with the liquid's speed (Faraday's law of induction). It has no moving parts in the flow. By the account of Jesse Yoder of Flow Research, a market research firm, a Dutch company introduced magmeters for commercial use in Holland in 1952 and Foxboro introduced them in the United States in 1954; more than 35 suppliers have entered the market since. Foxboro says a Model 1810 magmeter it installed in 1957 at Weyerhaeuser's pulp mill in Cosmopolis, Washington, was still running after more than 40 years.
Credit
the Dutch maker (named Tobinmeter by Yoder); Foxboro
1969
Counting eddies behind a bar
A vortex flowmeter places a blunt bar, called a bluff body, across the flow and counts the eddies (vortices) that break away from it, whose frequency rises with flow speed; it can measure liquids, gases and steam. Yokogawa introduced an insertion vortex meter for flare stacks in 1969 and its YEWFLO line of in-line meters in 1979. In the US, Alan Rodely applied for a vortex patent in 1969 that was granted in 1971 and assigned to Eastech. Writing in Control Global in November 2025, Jesse Yoder of Flow Research concludes that Yokogawa was "indisputably first" to market with an insertion vortex meter, and that it is unclear whether Eastech sold in-line meters before 1979.
Credit
Yokogawa; Alan Rodely and Eastech
1979
Mass flow from vibrating tubes
A Coriolis meter vibrates the tube the fluid flows through; the moving mass makes the tube twist slightly, and the twist gives the mass flow rate directly, without first measuring volume. Building on patents by Roby White (1958), Yao Tzu Li (1960) and Anatole Sipin (1965), Jim Smith applied in 1975 for a patent on oscillating the flow tube, formed Micro Motion in his garage in 1977 and introduced its first Coriolis flowmeter in 1979. Emerson bought Micro Motion in 1984, by Yoder's account.
Credit
Jim Smith, Micro Motion; Roby White, Yao Tzu Li and Anatole Sipin for the earlier patents
1998
Sound pulses meter traded gas
A multipath ultrasonic meter times sound pulses sent diagonally across the pipe on several paths, with the flow and against it; the difference in travel times gives the gas speed. British Gas developed one for natural gas in the early 1980s, and by 1998 several hundred were installed in pipelines worldwide and approved for legal metrology, the measuring that the law controls, in twelve countries, John Stuart of Pacific Gas and Electric wrote that year. In June 1998 the American Gas Association published Report No. 9, a recommended practice for using them in custody transfer, the metering on which gas is bought and sold. Unlike the orifice standard, it prescribes no meter design or pipe layout; it sets limits, such as a maximum error of ±0.7% for large meters before any flow calibration, and asks makers for test data showing their meters meet them.
Credit
the AGA's Transmission Measurement Committee; British Gas
2016
Wax skews an ultrasonic meter
On the Danish Oil Pipe, which carries crude oil 330 km from a North Sea platform to Fredericia, Denmark, two new 4-path liquid ultrasonic meters had each been calibrated to better than ±0.1%. When the second was installed in series with the first, 10 months after it, the two disagreed by about 1%. Investigators found wax in the cavities in front of the first meter's sound transducers, which changed the angle of the sound paths and made it under-read; against the tank gauges downstream, clean meters drifted until they read 0.5% to 1.2% low. Making the transducer housings stick out into the flow stopped the deposits but spoiled the meter's response to the flow near the pipe wall, and the fix kept was a fluoropolymer coating inside a standard meter, with cleaning at most six months apart.
LessonA meter can pass its lab calibration and still drift in service; here the drift showed only when a second meter ran in series and both were compared with the tanks.
Credit
Gregor Brown (Cameron, the maker) and Lars Bach (DONG Oil Pipe), who reported it at the North Sea Flow Measurement Workshop in October 2016
Watch for
Primary standard for liquid CO2
Carbon dioxide piped from capture plants to storage travels as a dense liquid or supercritical fluid, and the meters that bill it are calibrated with water or other fluids. TÜV SÜD's National Engineering Laboratory (NEL) in Scotland says it has completed the world's first SI-traceable primary standard flow facility for dense-phase CO2, a closed loop of 80 mm pipe that handles pure CO2 or CO2 with impurities at 0.7 to 70 m³/h and up to 200 bar. A 2025 NEL paper said no liquid or dense-phase CO2 calibration facility then held ISO/IEC 17025 accreditation, and it used the existing FALCON liquid CO2 loop at Norway's Institute for Energy Technology (IFE) for its tests.
Achieved whena comparison with another laboratory's CO2 flow standard is published and agrees within the stated uncertainties, or an accreditation body accredits the facility for CO2 calibrations.
Claimed by
TÜV SÜD NEL, February 2026
Open
01
An open magnetic flowmeter
An open-hardware magnetic flowmeter for clean water in a 25 mm pipe: a non-conducting pipe section with two stainless-steel electrodes, coils driven by a slowly switched current, and a low-noise amplifier and converter that turn the electrode voltage into a flow reading and a 4–20 mA signal, published with design files and a calibration against a traceable reference.
The briefCredit · unclaimed02
A meter selection test set
A public set of at least 200 metering duties, each written as an instrument data sheet (fluid, flow range, pressure, temperature, viscosity, electrical conductivity, pipe size, accuracy needed and straight pipe available), with the meter type and size chosen separately by three experienced instrument engineers, and a scored test of current AI models making the same choices.
The briefCredit · unclaimed
Open 01 · the brief
An open magnetic flowmeter
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open-hardware magnetic flowmeter for clean water in a 25 mm pipe: a non-conducting pipe section with two stainless-steel electrodes, coils driven by a slowly switched current, and a low-noise amplifier and converter that turn the electrode voltage into a flow reading and a 4–20 mA signal, published with design files and a calibration against a traceable reference.
Why it is still open
Magmeters have been sold since the 1950s, and every design in use is a maker's own. The open-source flow logger published in HardwareX in December 2024 by H. Guyard and colleagues measures water level at a channel by ultrasound, not flow in a full pipe. A 2024 paper from Xidian University describes a portable magmeter with errors within 0.3%, but no build files for it were found. A GitHub search for electromagnetic flowmeters returned one repository, a calculator for Rosemount meters' calibration factors.
Built with what exists
an acrylic or PVC pipe section with 316 stainless-steel electrodes; copper coils driven by a low-frequency square wave, as in the Xidian design; an instrumentation amplifier such as Analog Devices' AD8422 and a 24-bit converter such as TI's ADS1256; a Raspberry Pi Pico microcontroller; TI's XTR115 for the 4–20 mA output; KiCad for the circuit boards; a small pump, tank and pipe loop; as the reference, a weighing tank on a calibrated scale timed by the controller.
First step
Build the electrode body and one coil, drive it from a bench supply and record the electrode voltage at five flow rates, each timed into a bucket on a kitchen scale.
Done looks like
Readings within ±0.5% of the reference at ten flow rates from 0.5 to 3 m/s, repeated 30 days later without adjustment, with parts costing under US$300, and design files, firmware and raw data published under an open license.
Open 02 · the brief
A meter selection test set
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public set of at least 200 metering duties, each written as an instrument data sheet (fluid, flow range, pressure, temperature, viscosity, electrical conductivity, pipe size, accuracy needed and straight pipe available), with the meter type and size chosen separately by three experienced instrument engineers, and a scored test of current AI models making the same choices.
Why it is still open
Choosing a flowmeter is judgment that has been coded as rules since the 1980s, in expert systems such as FLOSEL, published by J. E. Lycett, T. Porter and D. Maudsley in 1988. Searches found no public set of duties with expert answers against which any method could be scored, and no published test of current AI models on the task.
Built with what exists
published process data and makers' public data sheets for the duties; AI models that answer fixed-choice questions (see the Note "A thousand questions, one pass"); the open Python library fluids by Caleb Bell, which carries ISO 5167 orifice calculations, to check pressure drop and sizing; a spreadsheet for the engineers' answers.
First step
Write 30 duties from published process data, ask two engineers to choose a meter for each, and run one AI model on the same 30.
Done looks like
All 200 duties answered by three engineers, with their agreement rate published; a model's choice counted as acceptable when at least two of the three engineers rate it workable; a model that scores at least 90% acceptable and makes none of the choices that cannot work, such as a magnetic meter on a liquid that does not conduct; duties, answers and code published.