BRENNEN

Industries / Industrial equipment and services / IoT and industrial automation

Process instrumentation

Process instrumentation is the trade that designs and makes the instruments that measure pressure, temperature, flow, level and the make-up of liquids and gases in plants such as refineries, chemical works, power stations and water works, and that send each reading on to the control system.

1888

On 18 September 1888 William H. Bristol of Hoboken, New Jersey, was granted US patent 389,635 for a pressure indicator and recorder, in which a bent metal tube connected to a boiler moved a pointer across a card turned by clockwork. The Bristol Company, which he founded with his brother Franklin in 1889, came to make recording and control instruments for temperature, pressure, flow and level, and in 1908 the brothers Edgar H. and Bennet B. Bristol set up the Industrial Instrument Company, renamed the Foxboro Company in 1914.

patents.google.comnaugatuckhistory.orgcontrolglobal.com

28

Milestones achieved across 6 domains.

7

To watch for: announced, not yet confirmed outside.

12

Open deliverables. Nobody has shipped them.

In one minute

Where it started

In the late 1880s makers such as the Bristol Company began selling gauges that drew a boiler's pressure on a chart turned by clockwork, and Clemens Herschel patented the Venturi meter to measure the water that mills drew from the canals at Holyoke, Massachusetts. Thermocouples (1886), the electronic pH meter (1934), the infrared gas analyzer (1938) and magnetic, vortex and Coriolis flowmeters (1952 to 1979) followed. In 1969 Rosemount's capacitance transmitter replaced the levers of older pressure instruments with a sealed sensor and small electronics.

Where it stands

A few large makers lead the trade: by their own reports, Endress+Hauser had sales of €4.01 billion in 2025, and Emerson's Measurement & Analytical segment, which includes Rosemount and Micro Motion, had $4.14 billion in the year to September 2025. Instruments now carry microprocessors that check their own health, report faults in four standard categories and are rated for safety duty under IEC 61508, and radar level sensors work at 80 GHz. Failures still set the rules: a thermowell that broke at Japan's Monju reactor in 1995 led to a new design standard in 2010, and a tank whose only gauge failed overflowed and exploded at a Puerto Rico terminal in 2009.

What is open

Many makers' claims have never been tested side by side in public: clamp-on thermometers said to match immersed ones, radars said never to need recalibrating, level switches that say they detect build-up, and the currents transmitters send when they fail. The magnetic flowmeter and the pH transmitter have no open, tested design, and no open tool rechecks old thermowells against the 2010 rule. A bench water loop, low-cost radar and converter chips, and AI models that read data sheets and certificates put these jobs within reach of a small team.

Domains

AchievedWatch forOpen

Open in process instrumentation

3 of 12 open deliverables

Open · Pressure and temperature

Test clamp-on sensors in public

A published bench test of clamp-on temperature sensors from several makers, mounted on one stainless-steel water loop beside a reference thermometer immersed in the flow, run at a range of water temperatures, flow speeds, air temperatures and wind, with and without insulation on the pipe.

Built with what exists

A loop of 25 mm (1 inch) stainless-steel pipe with a small circulating pump and a thermostatic water heater kept below 70 °C; a calibrated platinum resistance thermometer and readout, borrowed from a calibration laboratory, immersed in the flow as the reference; clamp-on sensors such as ABB NINVA and Omega HANI bought at list price; a desk fan for wind; a data logger and Python.

Credit · unclaimed

Open · Flow

An open magnetic flowmeter

An open-hardware magnetic flowmeter for clean water in a 25 mm pipe: a non-conducting pipe section with two stainless-steel electrodes, coils driven by a slowly switched current, and a low-noise amplifier and converter that turn the electrode voltage into a flow reading and a 4–20 mA signal, published with design files and a calibration against a traceable reference.

Built with what exists

an acrylic or PVC pipe section with 316 stainless-steel electrodes; copper coils driven by a low-frequency square wave, as in the Xidian design; an instrumentation amplifier such as Analog Devices' AD8422 and a 24-bit converter such as TI's ADS1256; a Raspberry Pi Pico microcontroller; TI's XTR115 for the 4–20 mA output; KiCad for the circuit boards; a small pump, tank and pipe loop; as the reference, a weighing tank on a calibrated scale timed by the controller.

Credit · unclaimed

Open · Level

Level sensors in foam

An open test column filled with water in which sensors of each main kind, 80 GHz radar, guided wave radar (a radar pulse sent down a rod or cable into the liquid), ultrasonic, and a pressure transmitter at the bottom, measure the same level while foam, stirring, condensation and a pipe inside the column are added one at a time, all compared against a reference reading.

Built with what exists

A clear acrylic column about 2 m tall on a drained floor; loaned or used sensors such as a VEGA VEGAPULS 80 GHz radar, an Endress+Hauser Micropilot FMR6xB, a KROHNE OPTIWAVE, a guided wave radar, an ultrasonic sensor and a submersible pressure transmitter; a side sight tube with a steel tape and a camera as the reference; an aquarium air pump and washing-up liquid for foam; a paddle mixer; a 4–20 mA data logger and HART modem; Python.

Credit · unclaimed

Where it sits