Analyzers

Analyzers are the instruments that measure what a process stream is made of, such as its acidity, its oxygen or its mix of gases, while the plant runs instead of in a laboratory afterwards.

4

Milestones achieved, from 1934 to 2004.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1934

    An electronic pH meter

    pH is the scale of how acidic or alkaline a liquid is, which Søren Sørensen introduced in 1909, yet industrial chemists kept using color tests well into the 20th century. In 1934 a former classmate who measured the acidity of lemon juice for the California Fruit Growers' Association asked Arnold Beckman for a sturdier electrical instrument. Beckman built an acidimeter around the then recently invented vacuum tube, the forerunner of what the Science History Institute calls the first commercially successful electronic pH meter, and sold it for $195 through his new firm, Beckman Instruments; its Model G was made from 1935 to 1950.

    sciencehistory.org

    Credit

    Arnold O. Beckman

  2. 1938

    Infrared light reads plant gases

    A non-dispersive infrared (NDIR) analyzer measures how much of a gas is present from how much infrared light it absorbs, without splitting the light into a spectrum. In 1938 Erwin Lehrer and Karl Friedrich Luft, chemists at BASF in Germany, developed the URAS (Ultra-Rot-Absorptions-Schreiber, an "ultra-red absorption recorder"), which BASF says could determine the concentration of more than 100 gases automatically. Until then samples were taken and analyzed in a nearby laboratory, so a contamination was found only after much of the gas had been processed further; BASF says the URAS simplified its ammonia synthesis, where carbon monoxide in the gas had repeatedly cost production, and that 1,122 had been built by 1986. ABB, which makes the line today, says gas-filled calibration cells added in 1988 removed the need for cylinders of high-pressure test gas.

    basf.comautomation.com

    Credit

    Erwin Lehrer and Karl Friedrich Luft (BASF)

  3. 1942

    Oxygen measured by magnetism

    On 3 October 1940 W. K. Lewis told Linus Pauling of Caltech that aircraft and submarine crews needed an instrument to measure the partial pressure of oxygen, the share of the air's pressure due to oxygen, to guard against running short. Pauling and Reuben Wood built one on a torsion balance: a glass dumbbell hung on a quartz fiber between the poles of a magnet turns because oxygen is paramagnetic, drawn into a magnetic field, and a mirror on the fiber moves a light beam across a photocell. By April 1942 more than 50 orders had come in, more than Caltech's workshop could build, and Arnold Beckman took a contract to manufacture the meter, reaching nearly 100 a month; after the war it kept oxygen at safe levels in incubators for premature babies.

    scarc.library.oregonstate.eduscarc.library.oregonstate.eduscarc.library.oregonstate.edu

    Credit

    Linus Pauling, Reuben Wood and Charles Sturdivant (Caltech); Arnold Beckman

  4. 2004

    Measuring during the process

    In 2004 the US Food and Drug Administration (FDA) issued guidance on process analytical technology (PAT), which it defines as "a system for designing, analyzing, and controlling manufacturing through timely measurements (i.e., during processing) of critical quality and performance attributes of raw and in-process materials and processes." It names three placings for an analyzer: at-line, where a sample is taken out and analyzed close by; on-line, where a sample is diverted and may be returned; and in-line, where the measurement is made in the process stream itself. It also allows real time release, passing a batch on its process data in place of tests on the finished product.

    LessonIn the FDA's words, "quality cannot be tested into products; it should be built-in or should be by design.".

    fda.govfda.gov

    Credit

    US Food and Drug Administration

Watch for

  1. Models in place of analyzers

    A predictive emission monitoring system (PEMS) estimates what leaves a stack from process readings the control system already collects, instead of measuring the gas with an analyzer. Yokogawa, which builds hardware emission monitoring systems, signed an agreement to sell and service the PEMS software of CMC Solutions, a US firm, outside the US. The companies say CMC's statistical models are "highly accurate", that its reports come in formats accepted by regulators including the US Environmental Protection Agency, and that it runs at more than 100 sites.

    Achieved whenregulators or independent auditors outside the US publish records of a PEMS running beside a reference analyzer at several sites for at least a year, with the differences between them.

    yokogawa.com

    Claimed by

    Yokogawa and CMC Solutions, February 2026

Open

  1. 01

    pH transmitter that checks glass

    An open-hardware pH transmitter that measures, besides pH, the electrical resistance of the electrode's glass membrane and of its reference junction, and flags electrodes that are cracked, worn out, coated or dried before their readings go wrong, tested blind on electrodes damaged in known ways.

    The brief
    Credit · unclaimed
  2. 02

    Check logs against the analyzers

    A tool that compares hand-entered readings in a water system's daily operating records with what the system's own data allow, such as the chlorine dosed, the water flow and any continuous analyzer, and flags entries that cannot be true for a person to check, tested first on a bench chlorination loop with false entries planted in its records.

    The brief
    Credit · unclaimed

Open 01 · the brief

pH transmitter that checks glass

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open-hardware pH transmitter that measures, besides pH, the electrical resistance of the electrode's glass membrane and of its reference junction, and flags electrodes that are cracked, worn out, coated or dried before their readings go wrong, tested blind on electrodes damaged in known ways.

Why it is still open

Analyzers from the large makers include such checks; Yokogawa's FLXA21 two-wire analyzer, for example, lists "sensor diagnostics and sensor wellness indication". Open and low-cost pH boards do not: the datasheet of Atlas Scientific's EZO-pH circuit, a common board in hobby and research builds, offers one- to three-point calibration and reports the calibration slope, and lists no electrode resistance check. Searches of Crossref and GitHub found no open transmitter with such checks and a published blind test.

web-material3.yokogawa.comfiles.atlas-scientific.com

Built with what exists

industrial combination pH electrodes, new and used; an amplifier with femtoampere input current, such as Analog Devices' ADA4530-1, to read the glass electrode without loading it; a small alternating test signal for the resistance checks; a Raspberry Pi Pico microcontroller; TI's XTR115 for the 4–20 mA loop; pH 4, 7 and 10 buffer solutions; KiCad for the circuit boards.

  1. First step

    Measure the glass resistance of five new and five old electrodes at 25 °C with a bench electrometer and see whether the two groups separate.

  2. Done looks like

    Forty electrodes in five known states (new, aged, cracked glass, coated with oil, dried-out junction), labeled by someone else and tested blind; at least 90% of faulty electrodes flagged, with no more than one false flag among the good ones; pH within ±0.05 in the buffers; design files and data published.

Open 02 · the brief

Check logs against the analyzers

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A tool that compares hand-entered readings in a water system's daily operating records with what the system's own data allow, such as the chlorine dosed, the water flow and any continuous analyzer, and flags entries that cannot be true for a person to check, tested first on a bench chlorination loop with false entries planted in its records.

Why it is still open

In Walkerton, Ontario, where contaminated water killed seven people and made more than 2,300 ill in May 2000, the inquiry found that for years the operators had made "false entries about residuals in daily operating records", that the provincial ministry's inspections should have caught the improper practices, and that continuous chlorine residual and turbidity monitors at the contaminated well would have prevented the outbreak. A Crossref search found anomaly detection on control-system data aimed at cyberattacks, and no tool or study that checks hand-entered readings against dosing records and analyzer data.

cbc.ca

Built with what exists

a bench loop of tap water dosed by a peristaltic pump with household bleach diluted to drinking-water levels (never mixed with acids); an online free-chlorine analyzer and a handheld DPD colorimeter, the standard color test for chlorine, as reference; Python for the chlorine balance; an AI model that reads scanned log sheets and flags problems in long records (see the Note "Seven more flagged").

  1. First step

    Run the loop for a week, log the chlorine residual by hand and by analyzer, plant ten false entries, and test a simple check that compares each logged residual with the chlorine dosed.

  2. Done looks like

    On 90 days of bench records with 50 false entries planted by a person who keeps the answer key, the tool flags at least 90% of them with no more than one false flag per 100 genuine entries; then one run on a utility's real records, compared with a manual audit.