Industries / Industrial equipment and services / Industrial services
Motor rewinding
Motor rewinding is the repair of electric motors and generators: finding what failed, stripping out a burned winding and winding new coils into the steel core, replacing insulation and bearings, balancing the rotor, and testing the machine before it goes back to work.
1933
On 4 August 1933, 23 electrical repair firms from eight southeastern US states, led by a group from Charlotte, North Carolina, met in Bluefield, West Virginia, and formed the National Industrial Service Association to write a code of practice for their trade under the National Recovery Act; it took the name Electrical Apparatus Service Association (EASA) in 1962.
36
Milestones achieved across 6 domains.
7
To watch for: announced, not yet confirmed outside.
13
Open deliverables. Nobody has shipped them.
In one minute
Where it started
Repair shops grew up with the electric motors that replaced steam engines in factories. By about 1920 McGraw-Hill sold a manual for "repairmen and armature winders in electrical repair shops", which told a winder to write down a machine's winding data before stripping it and to keep one old coil as a pattern. In 1933 US repair firms formed the association now called EASA, and it issued its first repair standards in 1945.
Where it stands
EASA counts more than 1,700 sales and service firms in nearly 70 countries. Electric motors use 43 to 46% of the world's electricity, by an International Energy Agency figure cited in a 2014 report for APEC, and the shops surveyed for that report said a motor is rewound one to three times in a life of 16 to 30 years, large motors more often than small ones. Two controlled studies by EASA and the UK's AEMT found that a rewind done to good practice keeps a motor's efficiency within the accuracy of the test.
What is open
Much of the trade's knowledge sits in shop records that nobody pools: surge test waveforms, core loss sheets, photos of burned windings and worn bearings, and the reasons a failed motor was repaired or replaced. Most open jobs turn those records into public data that can test old rules of thumb, train and score diagnostic tools, and check the assumptions regulators make. Others are bench tests, such as a robot that inserts coils into a one-off stator, and a count of bearing currents in the small 48 V motors of robot joints.
Domains
AchievedWatch forOpen
Domain
Progress
Last achieved
Watch for
Open
Testing and diagnosis
Testing and diagnosis is the work of finding out what is wrong with a motor or generator, and how close it is to failing, by measuring its insulation, its current, its vibration and its heat, in the shop or while it runs.
5 · 1 · 2
Last achievedResistance test revised2000
Watch forMotor faults from current alone
2
openStripping and rewinding
Stripping and rewinding is the work of removing a failed winding from the steel core, checking that the core is still sound, and winding new coils into it to the original design or a corrected one.
5 · 1 · 2
Last achievedA tighter limit for cores2026
Watch forBare-core designs from shared records
2
openInsulation
Insulation is everything that keeps current inside the copper of a winding: the enamel on the wire, the sheets and tapes between coils and iron, and the varnish or resin that binds them, and a rewind replaces all of it.
6 · 1 · 2
Last achievedTwo kinds of drive winding2005
Watch forNanoparticles in mica tape
2
openBearings and balancing
Bearings carry the turning shaft and are the part of a motor that fails most often, and balancing the rotor and aligning the shaft remove the forces that wear them out.
7 · 1 · 2
Last achievedA brush of fibers2007
Watch forCeramic balls against current
2
openEfficiency after repair
Efficiency after repair is the work of making sure a rewound motor uses no more electricity than it did before it failed, and proving it with tests.
6 · 1 · 3
Last achievedPremium motors keep efficiency2020
Watch forAn AI for repair questions
3
openDeciding to repair or replace
Deciding to repair or replace is the choice, when a motor fails, between repairing or rewinding it and buying a new one, weighing price, downtime, stock on hand, energy use and the law.
7 · 2 · 2
Last achievedA regulator moves the breakpoint2023
Watch forIE4 for large US motors
2
open
Figureheads
1 person
Advances to build with
2 research notes

NVIDIA GR00T 2
Five demonstrations per task
By NVIDIA's own test, its robot model GR00T 2 averages 95% success after five demonstrations of a task, on 50 tasks picked from those it learns that way.

Muse Ember
The jobs agents repeat
Meta's Muse Ember matched Claude Haiku 5.5 on an outside firm's tests at a third of the cost per task, though both list the same prices for text in and out.
Open in motor rewinding
3 of 13 open deliverables
Open · Testing and diagnosis
Surge tests from real failures
A public library of surge test waveforms that repair shops recorded on motors that came in failed or for overhaul, each tied to what the winder found when the motor was opened, and a classifier trained on it that flags turn faults and is scored on motors from a shop it never saw.
Built with what exists
Digital surge testers that already store each waveform (the shops run the tests; the builder handles only the files); Python with NumPy, SciPy and scikit-learn; a shared spreadsheet of teardown findings; phone photos of each opened winding.
Open · Stripping and rewinding
Core loss before and after
A public table of core loss readings taken before and after stripping on several hundred stators from several shops, with each motor's maker, build year, rating, oven temperature and number of earlier rewinds, to test whether newer cores lose more with each burnout.
Built with what exists
Core test sheets from accredited shops, scanned or exported from their core loss testers; an AI model that reads scanned forms into fields, with a person checking a sample; DuckDB or a spreadsheet; a simple regression of the change in W/lb on build year, oven temperature and number of rewinds.
Open · Insulation
Test the ten-degree rule
A public table of published thermal endurance results for motor insulation, from tests on materials, on magnet wire and on whole systems built as motorettes (small test windings), giving the life measured at each test temperature, and for each one the temperature rise that halves its life, fitted by the chemical-rate method Dakin set out in 1948.
Built with what exists
The Crossref and OpenAlex APIs to find papers, and free full-text reports from NASA's technical reports server, DTIC and OSTI; a model built for reading long scanned reports, such as Muse Ember (see the Note "The jobs agents repeat"), to pull life-versus-temperature tables; Python with SciPy for the fits; a spreadsheet.
Where it sits
Broader