Industries / Construction and property / Commercial and residential construction / Electrical contracting
Solar, battery and charger installs
This work mounts and wires rooftop solar panels, home and business batteries and electric-vehicle chargers, and takes each job through its permit, inspection and the utility's approval to switch on.
6
Milestones achieved, from 1984 to 2026.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
In depth
The same ground is charted in more depth, as an industry of its own.
The road
AchievedWatch forOpen
Achieved
1984
Solar enters the wiring code
The US National Electrical Code first covered solar photovoltaic (PV) systems, which turn light into electricity, in its 1984 edition, as Article 690. Ron Slade wrote in EC&M magazine that the industry "was not regulated until 1984". John Wiles of New Mexico State University, who wrote about the article for decades, recalled that the equipment then was simple and that its effect on the grid "was not fully realized".
Credit
NFPA's National Electrical Code committee
2021
Rooftop switches taken out
From 2012 Australia's installation standard, AS/NZS 5033, required a DC isolator, a switch that cuts the panels' direct current, on the roof beside the panels. Australia was the only country to require one. Water got into many of them. Renew, an Australian nonprofit, found that DC isolators caused between 38% and 50% of recorded solar fires in Western Australia and New South Wales from 2009 to 2015, and the Clean Energy Regulator found water in isolators the most common reason a system was rated unsafe. In November 2021 the Standards Australia committee EL-042 dropped the requirement, after more than 680 public submissions.
LessonA safety switch added on the roof became the largest single source of the failures it was meant to stop.
Credit
Standards Australia committee EL-042; Renew, with students of Worcester Polytechnic Institute
2021
Permits issued by software
SolarAPP+, built by the US National Renewable Energy Laboratory (NREL) with support from the installer Sunrun, checks a home solar design against the model building, electrical and fire codes and issues a permit at once if it passes. By NREL's review of its first full year, 2021, 102 installers got 3,291 permits through it in ten jurisdictions, median review time fell from 9 days to zero, and its projects were about 37% less likely to fail inspection than similar ones permitted the usual way. These are NREL's own figures; cities issue real permits through it as routine.
Credit
NREL; Sunrun
2022
A quarter of chargers fail
David Rempel and three colleagues tried all 657 connectors at the 181 open public fast-charging stations in the San Francisco Bay Area. Only 72.5% charged a car. For 4.9% the cable was too short to reach the car's charging port, and 22.7% failed through dead screens, payment or network faults, failure to start, or broken connectors. The station operators were reporting 95 to 98% uptime.
LessonUptime counted by the operator is not what drivers find, so reliability needs a shared definition and a third-party check.
Credit
David Rempel, Carleen Cullen, Mary Matteson Bryan, Gustavo Vianna Cezar
2023
Chargers must stay up
US federal rules for chargers built with National Electric Vehicle Infrastructure (NEVI) money, published on 28 February 2023, require each charging port to average more than 97% uptime over a year, calculated monthly over the previous 12 months.
Credit
US Federal Highway Administration
2026
Most battery installs mislabeled
Australia's Cheaper Home Batteries Program, a federal discount that began on 1 July 2025, led almost 250,000 households and businesses to install a battery by February 2026, by the Clean Energy Regulator's count. Of 350 finished inspections of these installs by 19 February 2026, the regulator rated 0.9% unsafe and 62.8% "substandard", meaning not compliant but safe to keep running. The most common faults were wrong or missing warning labels, including labels on circuits kept live by the battery and labels for emergency services. From 1 March 2026 installers must send geotagged, timestamped photos of these labels.
LessonA subsidy rush filled roofs and garages faster than installers got the labels right, and the labels are what the next electrician or firefighter relies on.
Credit
Clean Energy Regulator (CER)
Watch for
Plug-in solar without electricians
Plug-in or "balcony" solar is a small kit of panels that plugs into an ordinary wall socket, with no electrician and no utility review. Germany has more than 1 million such systems, by Stateline's account. Utah passed a law in 2025 for kits of up to 1,200 W, and by October 2026 twelve US states had passed such bills, nine signed into law. UL has issued a certification outline, but no product yet meets some states' requirements; an Electric Power Research Institute (EPRI) program manager said "There isn't yet a product that can meet the letter of the law", and electrical experts warn that US outlets were not designed to carry power in both directions.
Achieved whenA kit certified to UL's plug-in requirements is on sale in the US and a state publishes how many are installed and any fires or shocks.
Claimed by
Utah and other US state legislatures that allow the kits, 2025 to 2026
AI checks battery labels
Australia's Clean Energy Regulator says it has introduced an AI tool that helps its officers find problems with the required labels in installers' battery photos and checks the location and time data attached to each image. It has published no accuracy figures.
Achieved whenThe regulator or an outside auditor publishes how often the tool agrees with officers on a stated number of photo sets.
Claimed by
Clean Energy Regulator, July 2026
Open
01
Spot mismatched solar connectors
A photo set and a vision model that tell when the two halves of a solar panel cable connector come from different makers. Since 2020 the National Electrical Code says mated connectors that are not of identical type and brand must be listed and identified as able to mate. Mismatched pairs can build up resistance, heat and fail. Photos are taken of unpowered connector pairs on a bench and of finished arrays in permit photo packages.
The briefCredit · unclaimed02
Score battery install photo checks
An open test set of photos of home battery installs with planted faults, and published scores for tools that check such photos. The installs are mock-ups: real battery cabinets, switches and labels fixed to a training wall and never connected to power. Faults include missing or wrong warning labels, unlabeled backed-up circuits and missing emergency-services signs, the faults Australia's regulator found most often.
The briefCredit · unclaimed
Open 01 · the brief
Spot mismatched solar connectors
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A photo set and a vision model that tell when the two halves of a solar panel cable connector come from different makers. Since 2020 the National Electrical Code says mated connectors that are not of identical type and brand must be listed and identified as able to mate. Mismatched pairs can build up resistance, heat and fail. Photos are taken of unpowered connector pairs on a bench and of finished arrays in permit photo packages.
Why it is still open
Advanced Energy, a North Carolina nonprofit that inspects solar systems, wrote in November 2023 that connector mismatch is "all too common" and growing, because panel-level electronics often carry a different brand of connector from the panel's. Many brands are sold as "MC4-compatible" copies of Stäubli's MC4 and look alike. This research found no public photo set or tool that identifies connector brands, in searches of GitHub, Hugging Face, arXiv and Crossref.
Built with what exists
Samples of the ten or so most common connector families from suppliers; a phone with a macro lens; makers' datasheets for latch shapes and markings; Label Studio; an open image classifier or vision-language model.
First step
Buy five brands of connector, photograph 50 mated pairs of each combination, and test whether a person can tell the brands apart from the photos alone.
Done looks like
2,000 labeled photos of at least 10 connector families released openly, and on 200 held-out mated pairs, a published rate of mismatches caught and false alarms.
Open 02 · the brief
Score battery install photo checks
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open test set of photos of home battery installs with planted faults, and published scores for tools that check such photos. The installs are mock-ups: real battery cabinets, switches and labels fixed to a training wall and never connected to power. Faults include missing or wrong warning labels, unlabeled backed-up circuits and missing emergency-services signs, the faults Australia's regulator found most often.
Why it is still open
Australia's regulator rated 62.8% of inspected battery installs substandard, mostly for labels, and now runs an AI tool on installers' label photos, but has published no accuracy figures. SiteCapture, a US maker of field-photo software, launched an AI tool in March 2026 that reads labels and flags missing photos; its only figure, complete submissions rising from 30% to 80% in beta testing, is its own. SolarAPP+'s virtual inspections are judged by a person. There is no public set on which such tools can be measured and compared.
Built with what exists
A battery practice bay at a training college; printed label sets, correct and faulty; a phone camera; SolarAPP+'s published photo checklist as a template; Label Studio; an open vision-language model, or a model that answers a fixed yes/no checklist per photo (see the Note "A thousand questions, one pass").
First step
Ask a solar training college for an hour in its battery practice bay, and photograph it with five planted label faults.
Done looks like
1,500 labeled photos of 30 mock installs released under an open license, and at least one model scored on 300 held-out photos for label faults missed and false alarms.