BRENNEN

Industries / Transport and vehicles / Warehousing and distribution / Cold-chain logistics

Vaccines and medicines

This work keeps vaccines, insulin, blood and other biological medicines at their labeled temperature from the factory to the patient, often in places where the power supply is unreliable.

7

Milestones achieved, from 1977 to 2021.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1977

    Ghana's first cold chain

    WHO's Expanded Programme on Immunization began in 1974 with vaccines that, all but one, were spoiled by heat, and a few by freezing as well. WHO hired John Lloyd, an architect, and others to work with Ghana on a way to keep them cold from the national store to the village, and the pilot began in mid-1976. Lloyd found household refrigerators and picnic boxes made in Europe "completely inadequate" where the air is often above 40 °C and the power unreliable. His 1977 paper set out the design that other countries later copied: a central store with an alarm and a temperature recorder, regional freezers with a permanent store of ice, and insulated cold boxes that hold their temperature for seven days unopened. Manufacturers then built the ice-lined refrigerator, which holds a permanent buffer of ice to ride through power cuts.

    who.intgavi.org

    Credit

    John Lloyd; Ghana's health authorities; WHO

  2. 2007

    Freezing, not heat

    Some vaccines lose potency if they freeze. A 2007 review of published studies by Dipika Matthias and colleagues found that 14% to 35% of refrigerators or transport shipments had exposed vaccine to freezing temperatures. In studies that followed every stage of distribution, 75% to 100% of shipments had been exposed. A 2017 update covering 45 studies put exposure to temperatures below the recommended range during storage at 33% in wealthier countries and 37.1% in lower-income ones. Nepal's national study of 2025 found vaccines in range for more than 97% of 18,187 monitored hours, and still logged 272.5 hours below 2 °C, with one route reaching −12.1 °C.

    LessonA chain built to keep heat out can freeze what it carries. The 2007 authors found that the more rigorous a study was, the more freezing it found.

    ebi.ac.ukebi.ac.ukpmc.ncbi.nlm.nih.gov

    Credit

    Dipika Matthias and colleagues; Celina Hanson and colleagues; Nepal's Department of Health Services with UNICEF

  3. 2010

    Solar fridges drop batteries

    The solar vaccine refrigerators of the 1980s stored their energy in batteries. By WHO and UNICEF's account the batteries needed frequent maintenance, lasted three to five years and were costly and hard to replace. A solar direct-drive refrigerator has no battery: the panels run a compressor that freezes a bank of ice or similar material, and the ice keeps the vaccines cold at night and on cloudy days. WHO prequalified the first generation in March 2010, after 18 months of field tests in Senegal, Indonesia and Cuba. Gavi, the vaccine alliance, says that since 2017 it has helped buy more than 45,000 solar direct-drive units and more than 37,000 ice-lined units for more than 50 countries.

    LessonEquipment arrives faster than the means to keep it running. An independent evaluation in Guinea, Kenya and Pakistan, led by JSI, found that the new equipment contributed to more immunization services and that maintenance systems "need investment and re-visioning to be more effective.".

    unicef.orglog.logcluster.orggavi.orggavi.org

    Credit

    WHO; UNICEF; Gavi

  4. 2012

    Four days without ice

    A controlled temperature chain lets a vaccine leave refrigeration once, shortly before use, for a set number of days and up to a set temperature. In October 2012 the label of MenAfriVac, a meningitis A vaccine, was changed to allow up to four days at up to 40 °C. The paper reporting its first use calls this the first time a vaccine used in developing countries was authorized for use at ambient temperature. In December 2012 vaccinators in Banikoara district, Benin, used the allowance to reach 155,596 people. Of about 15,000 vials, nine were discarded for passing the four-day limit and none for passing 40 °C.

    pmc.ncbi.nlm.nih.gov

    Credit

    WHO; Benin's Ministry of Health

  5. 2015

    Vaccines kept at −60 °C

    The Ebola vaccine tested in Sierra Leone's STRIVE trial had to stay at −60 °C or colder, in a country that had no such storage. The trial team installed −80 °C freezers and moved vaccine between depots in Arktek containers, steel vacuum-insulated drums packed with frozen phase-change material, a substance that absorbs heat as it melts. In the field the containers held −74 to −70 °C for about five days. From 9 April to 12 December 2015 about 8,000 people were vaccinated, and the maker judged that none of five temperature excursions had harmed the vaccine. The Pfizer-BioNTech COVID-19 vaccine began with a similar label, −80 to −60 °C for frozen vials. On 25 February 2021 the FDA allowed two weeks at ordinary pharmaceutical freezer temperatures, after Pfizer submitted stability data.

    LessonA first storage label is set by the data in hand, and it loosens as stability data arrive. The FDA said the change would "ease the burden of procuring ultra-low cold storage equipment.".

    pmc.ncbi.nlm.nih.govfda.gov

    Credit

    the STRIVE team of Sierra Leone's College of Medicine and Allied Health Sciences and the US CDC; Global Good (Arktek)

  6. 2017

    Blood arrives by drone

    Blood products expire quickly and are hard to keep in stock at small hospitals. Rwanda began delivering them by drone, and a study in The Lancet Global Health counted 12,733 orders delivered between 17 March 2017 and 31 December 2019, 43% of them emergencies. The mean delivery took 49.6 minutes, 79 minutes faster than the blood service's estimates for road delivery. Expired blood units fell by 7.1 a month after drone delivery began, which the authors put at a 67% reduction after 12 months. The study was funded by the Canadian Institutes of Health Research.

    ebi.ac.ukzipline.com

    Credit

    Rwanda's government and its drone operator, Zipline; measured by Marie Paul Nisingizwe and colleagues

  7. 2021

    Insulin tolerates camp heat

    Unopened insulin is meant to be kept in a refrigerator at 2 to 8 °C, and 25 to 30 °C is usually allowed only for the four weeks a vial is in use. Researchers from the University of Geneva and Médecins Sans Frontières logged temperatures in Dagahaley refugee camp in northern Kenya, found them oscillating between 25 and 37 °C, and reproduced that pattern in a laboratory. After four weeks every insulin product tested still met pharmacopeia limits and acted on liver cells as well as samples kept cold. A 2019 study put sensors beside the insulin of 338 people, most of them in the United States and Europe. Refrigerated insulin was out of range 11.3% of the time, and 17% of sensors recorded temperatures below 0 °C; three of that study's five authors worked for MedAngel, the sensor's maker.

    LessonA storage rule that cannot be followed should be tested, not assumed. The Geneva authors concluded that insulin in use can be kept at such temperatures for four weeks.

    pmc.ncbi.nlm.nih.govebi.ac.uk

    Credit

    Beatrice Kaufmann and colleagues (University of Geneva; Médecins Sans Frontières); Katarina Braune and colleagues

Watch for

  1. A fridge-free tetanus-diphtheria shot

    Stablepharma, a British firm, says its reformulated tetanus-diphtheria vaccine, SPVX02, is designed to stay stable at 30 °C for up to four years without refrigeration and is not affected by freezing. A phase 1 trial, the first small safety test in people, gave it or a licensed vaccine to 60 healthy adults in Southampton. The company says the results were published in eClinicalMedicine and that it has started a pivotal phase 2b trial.

    Achieved whenA regulator licenses the vaccine with a room-temperature storage label, or an outside laboratory confirms its potency after storage at 30 °C.

    stablepharma.comstablepharma.com

    Claimed by

    Stablepharma, October 2026

  2. Drones for 15,000 clinics

    Zipline says an award of up to $150 million from the US State Department, paid as it meets agreed targets, could triple the hospitals and health facilities its drones serve in Africa, from 5,000 to 15,000. The countries pay for the delivery service themselves, and Zipline expects Rwanda to sign first. Zipline says it has made 1.8 million deliveries since 2016.

    Achieved whenGovernments have signed, and an outside study reports the number of facilities served and the effect on stock-outs or waste.

    zipline.com

    Claimed by

    Zipline, November 2025

Open

  1. 01

    Vial-monitor math for loggers

    Open-source code that reads a refrigerator or shipment logger file and estimates how much of a vaccine vial monitor's heat life the recorded temperatures would have used, for each type of monitor. The estimate is checked against real monitor labels, blank samples with no vaccine, aged in an oven beside a logger. It is a study tool and does not replace the label on a vial.

    The brief
    Credit · unclaimed
  2. 02

    Read allowances from every label

    A public table, built by software, of what each US drug label says about time out of the refrigerator. For every product labeled for storage at 2 to 8 °C, the table gives the allowance if the label states one, the exact sentence and a link to it, and it lists the labels that say nothing. It carries a notice that it is a reference for pharmacists, not advice for a patient.

    The brief
    Credit · unclaimed

Open 01 · the brief

Vial-monitor math for loggers

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

Open-source code that reads a refrigerator or shipment logger file and estimates how much of a vaccine vial monitor's heat life the recorded temperatures would have used, for each type of monitor. The estimate is checked against real monitor labels, blank samples with no vaccine, aged in an oven beside a logger. It is a study tool and does not replace the label on a vial.

Why it is still open

WHO's specification publishes each type's time to end point: for a VVM30, 30 days at 37 °C and 193 days at 25 °C; for a VVM7, 7 days and 45 days. Two points are enough to fit the Arrhenius equation, the standard formula for how a reaction speeds up with temperature. Yet a GitHub search for "vaccine vial monitor" on 18 November 2026 returned no projects. Nepal's 2025 national study summarized its logger files by time in range and by mean kinetic temperature, a single heat-weighted average, and reported the vial monitor readings separately.

extranet.who.intpmc.ncbi.nlm.nih.gov

Built with what exists

The reaction-rate table in WHO's specification WHO/PQS/E006/IN05.4; Python; the Varo Foundation's open parser for Fridge-tag logger files; sample monitor labels requested from the maker; a laboratory incubator or a steady oven with a logger inside; a phone camera on a timer to record the color change.

github.com

  1. First step

    Fit the two published points for VVM7, VVM14 and VVM30, then replay one published logger trace and report the share of heat life it would have used.

  2. Done looks like

    For three monitor types and three temperature profiles, one of them cycling between cold and hot, the predicted time to end point falls within 10% of the time observed, on at least 20 labels per profile. The code, logger files and photographs are public.

Open 02 · the brief

Read allowances from every label

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table, built by software, of what each US drug label says about time out of the refrigerator. For every product labeled for storage at 2 to 8 °C, the table gives the allowance if the label states one, the exact sentence and a link to it, and it lists the labels that say nothing. It carries a notice that it is a reference for pharmacists, not advice for a patient.

Why it is still open

The tables pharmacists use are compiled by hand. A 2022 review spent 12 months going through the 705 products approved in the US since 2000, found 246 that need storage below room temperature, and phoned or emailed makers where nothing was published. A 2025 review covered 150 medications from one hospital's list. Searches of Europe PMC and GitHub in November 2026 found no machine-built version.

ebi.ac.ukpmc.ncbi.nlm.nih.gov

Built with what exists

DailyMed, the US National Library of Medicine's public collection of drug labels, with its download files and web services; a low-cost model built for extraction and long document parsing, such as Muse Ember (see the Note "The jobs agents repeat"); a second model that checks each extracted sentence against the label; a pharmacist to audit a sample.

dailymed.nlm.nih.gov

  1. First step

    Download the labels of 100 refrigerated biologic medicines, extract their storage sentences with one model, and compare 20 rows by hand with the 2025 table.

  2. Done looks like

    Every current label with 2 to 8 °C storage is processed. For the 214 products with an allowance in the 2022 hand-built table, the software's reading of the label matches the table at least 95% of the time where the label states an allowance, and each mismatch is explained. A pharmacist checks 200 random rows. The table is rebuilt every month.