Industries / Industrial equipment and services / Industrial machinery / Valves
Testing
Testing is the set of pressure, leak, fire and flow checks that a valve, or a sample of its design, goes through at the factory or in a laboratory before it is sold or approved.
5
Milestones achieved, from 1935 to 2025.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1935
Relief valves flow-tested
A pressure relief valve opens to let fluid out before a vessel bursts, and its rated capacity says how much it can let out. The National Board of Boiler and Pressure Vessel Inspectors sponsored relief valve tests at Ohio State University's Robinson Mechanical Engineering Laboratory in 1935, when design testing was added to the ASME Code for safety valves. It built its own laboratory in 1974, began testing samples picked at random from production in 1976 and opened its present laboratory in 1991, which by the Board's count ran 53,804 tests in its first 30 years. Certified designs are listed in the Board's free NB-18 database, and each certification lasts six years.
Credit
National Board of Boiler and Pressure Vessel Inspectors; Ohio State University
1961
Pressure tests written down
When the American Petroleum Institute (API) first published API 600, its standard for steel gate valves in refineries, in 1939, the test rule was simply that a valve must not leak, by the account of Greg Johnson in Valve Magazine. The Manufacturers Standardization Society (MSS) published SP-61, "Pressure Testing of Valves", in 1961, and API followed in 1968 with API 598, "Valve Inspection and Test", which Johnson calls the most widely used valve testing standard in the United States.
Credit
Manufacturers Standardization Society; American Petroleum Institute
1976
Leakage classes for control valves
A control valve is built to throttle flow, and not every design is meant to shut off completely. ANSI B16.104 of 1976, since replaced by ANSI/FCI 70-2 of the Fluid Controls Institute, sets six classes of seat leakage, the flow that still passes a closed valve, each with its own shop test. Class IV, for metal plugs on metal seats, allows 0.01% of the valve's full-open capacity in a test with air at 45 to 60 psig (3.1 to 4.1 bar); Class VI, for soft seats of a resilient material such as PTFE, allows from 0.15 ml of air a minute for a 1-inch valve to 6.75 ml for an 8-inch valve, counted as bubbles, by the account of the valve maker SVF Flow Controls.
Credit
Fluid Controls Institute; American National Standards Institute
1994
Fire tests at low pressure
A fire test burns a closed valve for 30 minutes in flames of 760 to 982 °C, then measures what leaks through it and out of it. Exxon had one of the earliest fire tests, in which a valve pressurized with kerosene was burned, a test that endangered the people running it; after a large fire at one of its Baton Rouge chemical plants in 1994, it accepted valves qualified to the fourth edition of API 607, released that year. That edition was the first to test soft-seated valves, whose seats are plastic, at a lower pressure as well, because line pressure can fall in a plant fire once pumps stop.
Lessonball valves of 3 to 4 inches had the most trouble, because their seats burned only partly and the leftover char could lodge between ball and body.
Credit
American Petroleum Institute; Exxon
2025
Certified in pure hydrogen
ISO 15848-1 is the international type test for gas leaking from a valve's stem and body seals, usually run with helium or methane, and hydrogen, a smaller molecule, escapes through seals more easily. In February 2025 Trillium Flow Technologies said that TÜV SÜD, a testing and certification company, had certified its Blakeborough control valves after tests in 99.9% pure hydrogen at cryogenic and room temperatures, which met tightness class A, the tightest, at endurance classes CO1 and CC1 of ISO 15848-1.
Credit
TÜV SÜD; Trillium Flow Technologies
Watch for
A 500 bar hydrogen valve
HEROSE of Germany says its Type 01C07 globe valve, for tube trailers and other transportable hydrogen containers at up to 500 bar, passed hydrogen leak tests across its whole operating temperature range and 10,000 full pressure cycles, and has entered service in the first systems of a global gas supplier it developed the valve with.
Achieved whena notified body or the gas supplier publishes the test results or a service record.
Claimed by
HEROSE, August 2026
Open
01
Check test reports by machine
An open checker that reads a valve's factory test report, as a PDF or a photo, and checks that every test the order calls for is present (shell, backseat and seat tests), that pressures and hold times meet the limits for the valve's size and pressure class, and that the recorded leakage is within the allowance of the standard named. The limits are entered by the user from a licensed copy of the standard. It is published with a test set of made-up reports carrying planted errors.
The briefCredit · unclaimed02
Robot leak sniffing, tallied
A low-pressure bench where a robot arm sweeps a helium sniffer, a probe that draws in air and detects helium, over a valve's stem seal, bonnet joint and end connections, on valve designs it was not trained on, with calibrated helium leaks hidden at random points, and a filmed, published count of leaks found by the robot and by a trained person on the same valves.
The briefCredit · unclaimed
Open 01 · the brief
Check test reports by machine
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open checker that reads a valve's factory test report, as a PDF or a photo, and checks that every test the order calls for is present (shell, backseat and seat tests), that pressures and hold times meet the limits for the valve's size and pressure class, and that the recorded leakage is within the allowance of the standard named. The limits are entered by the user from a licensed copy of the standard. It is published with a test set of made-up reports carrying planted errors.
Why it is still open
Buyers' guides still hand people a checklist to work through by hand. STV Valves' 2025 guide lists valve identity, standard, test pressures, test medium, durations, leakage and inspector sign-off, and its red flags include missing tests and pressure not held for the full time. The nearest open tool, MillProof (GitHub, November 2026), has Claude read steel mill test certificates and checks them with fixed rules for IS 2062 and ASTM A36 plate, not valve pressure tests, and a GitHub search in November 2026 found no repository for valve test certificates.
Built with what exists
An AI model that reads documents and photos, such as Claude (the Note "Seven more flagged" covers a Claude-based reviewer that found issues people had missed in long records); fixed rules in Python for each pass or fail; a table of limits supplied by the user; made-up reports generated from document templates.
First step
Write 30 made-up reports for gate and ball valves in two pressure classes, plant 10 errors, and score a first version against them.
Done looks like
On 300 made-up reports holding 100 planted errors of six kinds (missing test, low pressure, short hold, wrong test medium, leakage over the allowance, mismatched serial number), the checker finds at least 95 with no more than 10 false flags; the same scoring on at least 50 real reports, with names removed, from buyers who agree to share them.
Open 02 · the brief
Robot leak sniffing, tallied
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A low-pressure bench where a robot arm sweeps a helium sniffer, a probe that draws in air and detects helium, over a valve's stem seal, bonnet joint and end connections, on valve designs it was not trained on, with calibrated helium leaks hidden at random points, and a filmed, published count of leaks found by the robot and by a trained person on the same valves.
Why it is still open
Neles told Valve Magazine in 2021 that it runs high-pressure helium tests with a collaborative robot and a sniffing program inside an explosion-proof enclosure, and Arçelik's air conditioner plant in Turkey uses a UR5e collaborative robot with a sniffer probe, guided by Mech-Mind cameras to each weld (Assembly Magazine, October 2025). Neither reports how many leaks the robot finds, and Valve Magazine wrote in April 2026 that the wide mix of valve sizes and types makes automation harder for valve makers than for high-volume plants.
Built with what exists
A low-cost arm such as the SO-101 with Hugging Face's LeRobot software (the Note "No download"); a policy learned from a few demonstrations, such as NVIDIA's GR00T 2 (the Note "Five demonstrations per task"); a helium sniffer leak detector; calibrated helium reference leaks; small valves filled with helium, which does not burn, at no more than 2 bar; a camera to film each trial.
First step
Fit one reference leak to a small ball valve at low pressure and film a person sweeping it 20 times, as the first demonstrations.
Done looks like
On 10 valve designs not used in training, 100 trials, each with a reference leak at one of four points chosen at random; the share of leaks found and the minutes per valve for the robot and for a person, published with the film and the raw sniffer readings.