BRENNEN

Industries / Industrial equipment and services / Industrial services / Rope access

Inspection work

Inspection work sends engineers and technicians down ropes to look at, tap and measure façades, monuments, bridges and plant at arm's length, where binoculars or a camera from the ground cannot judge the condition.

5

Milestones achieved, from 1980 to 2022.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1980

    Façade checks become law

    After a Barnard College student was killed by a piece of falling terracotta, New York City's Local Law 10 of 1980 made owners of buildings over six stories hire private inspectors to examine their exterior walls once every five years and file the reports with the city. Local Law 11 of 1998 widened the checks from street-facing walls to all façades, and the program became the model that much hands-on façade work, from scaffolds and from ropes, now serves.

    LessonOne death turned façade inspection from an owner's choice into a five-yearly legal duty.

    nyc.gov

    Credit

    New York City Council; NYC Department of Buildings (DOB)

  2. 2011

    Rappelling the Washington Monument

    A magnitude 5.8 earthquake on 23 August 2011 cracked, spalled and displaced stones of the Washington Monument. The National Park Service (NPS) and the Difficult Access Team of the engineering firm Wiss, Janney, Elstner Associates (WJE) chose rope access for the first assessment because of the urgency and the hazard from loose stone; four engineers each took one face and inspected it block by block, and the last drops were made on 5 October 2011. The team's own account in ASCE's Civil Engineering magazine says no one had rappelled down the monument since it was finished in 1884.

    nps.govwje.com

    Credit

    NPS; WJE's Difficult Access Team (Emma Cardini, Kathryn Francis, Daniel Gach, David Megerle, Erik Sohn), with Tipping Mar Associates

  3. 2016

    Tapping a million tiles

    The Art Newspaper reported in December 2016 that the roughly one million glazed tiles on the Sydney Opera House's 65 m concrete roof sails are hand-checked every five years by engineers who abseil down the sails, tapping each tile and listening for a change in its sound. The Opera House, the Getty Foundation, the University of Sydney and the engineering firm Arup were adding a microphone and sensors to the tapping hammers to make the readings more consistent.

    theartnewspaper.com

    Credit

    Sydney Opera House building staff and abseiling engineers; Getty Foundation's Keeping It Modern grants; University of Sydney; Arup

  4. 2020

    A drop every 60 feet

    On 17 December 2019 Erica Tishman was killed by material falling from a building façade in Manhattan. On 30 December DOB announced a stricter façade rule, enacted in 2020, that requires more hands-on inspection. The rule now in force requires close-up physical examinations at intervals of no more than 60 ft (18 m) along every wall facing a street, from grade to the top, and states that drones, high-resolution photography and nondestructive testing "does not eliminate the requirements for close-up inspections." DOB's 2021 drone report says these close-ups are usually made from a swing stage, a platform hung from the roof, and sometimes by industrial rope access, and that the inspector can sound materials and remove loose pieces during them.

    LessonThe city answered a death by requiring more inspectors within arm's reach of the wall, not more photographs.

    nyc.govnyc.govnyc.gov

    Credit

    NYC DOB

  5. 2022

    Arm's length, by rule

    The US Federal Highway Administration's revised National Bridge Inspection Standards, in force from 6 June 2022, define a hands-on inspection as one made "within arm's length of the member" and require it for every nonredundant steel tension member (NSTM), the rule's new name for a steel part in tension whose failure could bring down part or all of a bridge, which earlier rules called a fracture critical member. Engineers at Modjeski and Masters, which started its rope access program in 2000, wrote in ASCE's Civil Engineering in 2025 that rope access is now used next to under-bridge trucks to reach such members.

    govinfo.govlaw.cornell.eduasce.org

    Credit

    US Federal Highway Administration; Modjeski and Masters

Watch for

  1. Fewer drops in New York

    A review of New York City's façade program, written for DOB by the engineering firm Thornton Tomasetti and dated 10 December 2025, which DOB calls the first evidence-based study of the program, recommends letting newer, well-maintained façades go 12 years between hands-on inspections if they file visual-only inspections every three years.

    Achieved whenDOB adopts a rule with the longer interval and publishes how many unsafe conditions the visual-only inspections found and missed.

    nyc.govnyc.gov

    Claimed by

    Thornton Tomasetti for NYC DOB, December 2025

  2. Laser scans replace climbing

    Abyss Solutions says a team of five used laser scanners to capture a 10,000-tonne semi-submersible oil platform in the Gulf of Mexico in 14 days, and that its Abyss Fabric software reached 97% coverage of the equipment, where the operator's manual general visual inspection covered 20% a year, and flagged 83 items for urgent replacement. The same article describes flare stacks inspected today by people climbing on ropes.

    Achieved whenthe operator or an independent inspector publishes the scan's findings set against hands-on findings on the same equipment, including what each missed.

    onestopndt.com

    Claimed by

    Abyss Solutions, June 2026

Open

  1. 01

    Count what drones miss

    A public comparison, for real façades in New York City, of what a drone survey showed and what the hands-on drops found on the same walls, built from inspection records that already exist. For each façade, every unsafe or SWARMP condition (DOB's "safe with a repair and maintenance program", meaning safe now but needing repair within five years) found by hand is listed, and two reviewers mark whether it can be seen in the drone images. No one flies or climbs for the study.

    The brief
    Credit · unclaimed
  2. 02

    Measure the human tap test

    A blind bench test of how reliably inspectors find hollow tiles, render or stone by tapping, the check that hands-on inspection exists to make. Panels with tiles or render bonded over hidden voids of known size and position are built and tested on the ground. Inspectors tap them without seeing the void map, and a phone records every tap so that a published tap-sound model, and then a thermal camera on a tripod, can be scored on the same panels.

    The brief
    Credit · unclaimed

Open 01 · the brief

Count what drones miss

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public comparison, for real façades in New York City, of what a drone survey showed and what the hands-on drops found on the same walls, built from inspection records that already exist. For each façade, every unsafe or SWARMP condition (DOB's "safe with a repair and maintenance program", meaning safe now but needing repair within five years) found by hand is listed, and two reviewers mark whether it can be seen in the drone images. No one flies or climbs for the study.

Why it is still open

DOB's 2021 report found "limited experience" with drones for façade inspection and too little data to say how they might support it; the December 2025 review recommends a pilot of real test cases before drones exempt any building from hands-on drops; and the Strathclyde trial measured drone pilots on one test wall, not on buildings. A search found no published comparison of drone and hands-on findings on the same real façades.

nyc.govnyc.govstrathprints.strath.ac.uk

Built with what exists

Paired drone and close-up records from Qualified Exterior Wall Inspectors (the licensed engineers and architects who file New York's façade reports) who used both in the current cycle; DOB's public list of façade filings on NYC Open Data, which names each filing's inspector, wall material and status; OpenDroneMap, open-source software that stitches drone photos into a measured image of a whole façade; a model that answers fixed yes-or-no questions about each image, such as Google's Gemini Decision 1 (Note: "A thousand questions, one pass"), to pre-sort photos before people check them.

  1. First step

    Use the façade filings data to list the firms filing reports in the current cycle, and ask five of them for one paired drone and hands-on record each, with the owner's consent.

  2. Done looks like

    At least 30 façades from at least five inspection firms; every hands-on finding listed by type (crack, spall, displaced unit, failed sealant, corroded anchor or tie) and marked seen or not seen in the drone images by two reviewers working apart, with their agreement reported; the share missed published by defect type and wall material.

Open 02 · the brief

Measure the human tap test

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A blind bench test of how reliably inspectors find hollow tiles, render or stone by tapping, the check that hands-on inspection exists to make. Panels with tiles or render bonded over hidden voids of known size and position are built and tested on the ground. Inspectors tap them without seeing the void map, and a phone records every tap so that a published tap-sound model, and then a thermal camera on a tripod, can be scored on the same panels.

Why it is still open

Singapore requires contact checks with a tapping rod or rubber mallet on at least 10% of every face of a building, and New York's close-up inspection is where an inspector "is able to sound various materials." Researchers have trained models to sort tap sounds from tiles, writing that sounding by ear "relies on skill and judgment that greatly vary among individuals" (Panyavaraporn and Horkaew, 2024), and have tested a tapping device on 12 tiled specimen walls (Soeta and others, 2021). A Crossref search found no published detection rate for human inspectors on blind panels, and no shared panel set with a published void map on which methods can be compared.

isomer-user-content.by.gov.sgdoi.orgdoi.org

Built with what exists

Ceramic tiles, render and stone set on concrete boards by a tiler, with inserts that leave voids of chosen sizes; rubber mallets and tapping rods; phones to record sound; Python with the librosa and scikit-learn libraries to rebuild the 2024 paper's method (sound features called MFCCs fed to a support vector machine); a thermal camera on a tripod.

  1. First step

    Build two panels with mapped voids and record 200 taps from three people.

  2. Done looks like

    At least 10 working façade inspectors each tap 20 panels blind; the share of voids found and the false calls published by void size and material; the model's and the thermal camera's results on the same panels set beside theirs; the void map and every recording released so others can test against them.