Rigging is setting up what a technician hangs from: two ropes, each tied to an anchor, a device for moving up or down the working line and a backup device on the safety line.

5

Milestones achieved, from 1958 to 2021.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1958

    A clamp that climbs rope

    Walter Marti of Switzerland filed a patent on 22 March 1958 for a "rope climbing device": a handle with a spring-loaded toothed cam that slides up a rope and locks when pulled down, with a foot loop hanging below. Sold as the Jumar, it is a mechanical rope clamp of the kind now called an ascender. Europe's standard for rope access devices still names the ascender (Type B) as one of the two devices a technician uses on the working line.

    patents.google.comcdn.standards.iteh.ai

    Credit

    Walter Marti, Swiss patent CH 362351, published 31 May 1962

  2. 2002

    A sharp-edge test withdrawn

    The UIAA, the international climbing federation, introduced a test called UIAA 108 in 2002 to label climbing ropes "sharp edge resistant": 80 kg was dropped from 4.8 m with the rope running over an edge with a 0.75 mm radius, and a rope that held one fall passed. According to the rope maker Edelrid, the test was suspended in 2004 because the same rope gave different results in different tests, and no later proposal reached an acceptable level of reliability.

    LessonAn edge test is only useful if every laboratory gets the same answer from the same rope.

    edelrid.com

    Credit

    the UIAA; account by Edelrid

  3. 2006

    A standard for rope devices

    Europe's standard EN 12841, first published in 2006, sets the tests for the three devices that join a technician to the ropes: Type A on the safety line, Type B ascenders and Type C descenders on the working line. Its 2024 edition, approved by CEN, the European standards body, on 17 December 2023, replaced the 2006 text. It says it is "fundamental" that the worker is always connected to both lines with no slack, and it tests descenders for descent speed and for panic locking, which must stop the descent if the user works the handle beyond its intended range.

    cdn.standards.iteh.ai

    Credit

    CEN technical committee CEN/TC 160

  4. 2012

    Anchors split by the law

    The European anchor standard EN 795 was revised in July 2012, but a formal objection by the French government kept the 1996 version as the one recognised under EU law until 11 December 2015. Even then only portable anchors (Type B) and deadweight anchors (Type E) counted as personal protective equipment. Anchors fixed to a structure (Types A, C and D) did not, so the standard is guidance for them, not a route to certification. Anchors for more than one person at a time were left to a separate document, CEN/TS 16415:2013.

    LessonThe same standard can be law for one anchor and only advice for another, depending on whether it is fixed to the structure.

    insst.es

    Credit

    CEN/TC 160; account by Spain's National Institute for Safety and Hygiene at Work (INSHT), May 2016

  5. 2021

    Glass cuts the main line

    In May 2021 a rope access technician cleaning windows on an eight-storey building in British Columbia fell about 11 m and was seriously injured. The edge of a glass pergola cut through the canvas sleeve protecting his working line and then through the rope, and the fall arrester on his safety line, the device meant to grip that line in a fall, did not engage. WorkSafeBC, the province's safety regulator, found that the supplier gave no direction on choosing edge protection, that the training manual of SPRAT, the Society of Professional Rope Access Technicians, lacked information on choosing and using it, and that no standard governs how edge protection is designed or used.

    LessonTwo ropes protect a worker only if the edge cannot reach the second line and the backup device works.

    worksafebc.com

    Credit

    WorkSafeBC, report summary published September 2023

Watch for

  1. An amended rope device standard

    DIN, Germany's standards body, lists an amendment to EN 12841:2024, numbered EN 12841:2024/prA1:2026 and prepared by CEN's working group on fall protection equipment (CEN/TC 160/WG 3). Work began on 29 August 2025 and the draft is dated July 2026.

    Achieved whenCEN publishes the amendment and makers certify descenders to it.

    din.de

    Claimed by

    CEN/TC 160 through DIN, August 2025

Open

  1. 01

    Bench-test edge protectors

    A ground-level test bench that holds a rope access rope at a set tension over an edge sample (a 90° steel angle, a cut edge of toughened glass and a concrete edge) while a motor slides the edge back and forth across the rope, as a technician moves sideways below. It counts the cycles until each commercial edge protector is cut through and then until the rope's sheath is cut, and the results are published as a table.

    The brief
    Credit · unclaimed
  2. 02

    Grab the backup, then drop

    A laboratory comparison of how rope access backup devices behave when the user's hand is clamped around them during a fall. A pneumatic gripper set to a measured human grip holds each device while a steel test mass falls on the safety line in a drop rig, with no person on the rope. For each drop the test records whether the device locked and how far it slid.

    The brief
    Credit · unclaimed

Open 01 · the brief

Bench-test edge protectors

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A ground-level test bench that holds a rope access rope at a set tension over an edge sample (a 90° steel angle, a cut edge of toughened glass and a concrete edge) while a motor slides the edge back and forth across the rope, as a technician moves sideways below. It counts the cycles until each commercial edge protector is cut through and then until the rope's sheath is cut, and the results are published as a table.

Why it is still open

WorkSafeBC found in 2023 that no standard governs how edge protection is designed or used. The one standard sharp-edge test for ropes, UIAA 108 for climbing ropes, was suspended in 2004 because its results were not repeatable, and Edelrid writes that no later proposal reached acceptable reliability. A search found makers' in-house rope tests and marine chafe-guard tests, but no published comparison of rope access edge protectors.

worksafebc.comedelrid.com

Built with what exists

a universal testing machine of the kind university materials laboratories have (Instron and ZwickRoell make them) or a steel frame with a screw actuator; a load cell; a geared motor on a linear slide; an Arduino or Raspberry Pi to log tension and count cycles; a phone camera; EN 1891 low-stretch rope; ten edge protectors bought from rope access suppliers. Everything runs on a bench, behind a guard, with nobody on a rope.

  1. First step

    Build the bench and run ten bare-rope tests on one steel edge, to learn how much the results scatter before any protector is tested.

  2. Done looks like

    Ten protectors tested on three edges, five runs each, with the median cycles to failure and the spread published; the bare-rope runs repeated in a second laboratory, with the difference between the two laboratories stated.

Open 02 · the brief

Grab the backup, then drop

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A laboratory comparison of how rope access backup devices behave when the user's hand is clamped around them during a fall. A pneumatic gripper set to a measured human grip holds each device while a steel test mass falls on the safety line in a drop rig, with no person on the rope. For each drop the test records whether the device locked and how far it slid.

Why it is still open

In the 2023 Stampede case investigated by BSEE, the US offshore safety regulator, a technician held his rope protector down over his backup device and defeated it, and fell 90 ft (27 m). BSEE quotes the device maker's warning that the "natural human reflex is to increase the grip", and an IRATA bulletin reporting that, in tests at the maker's headquarters, even an experienced technician who expected the fall failed to let go of the cord in 25% of tries. The US Bureau of Reclamation's drop tests of eight backup devices measured peak force and slip but not a gripped device, and a search found no published test that compares devices under a grip, only makers' "anti-panic" claims.

bsee.govusbr.gov

Built with what exists

the drop rig of an accredited test laboratory that certifies devices to EN 12841; a pneumatic parallel gripper (Festo and SMC make them) with a pressure regulator; a load cell; a phone camera filming at 240 frames a second; eight or more backup devices on sale.

  1. First step

    On a tensile bench, pull rope slowly through each device while the gripper holds it and note which devices still lock; this needs no drop rig.

  2. Done looks like

    At least eight devices, each dropped five times with the gripper closed and five times without, with lock or no lock and slide distance for every drop published, with video, and signed off by the laboratory.