Industries / Construction and property / Commercial and residential construction / Roofing
Inspection and leaks
Inspection is finding where water gets through a roof and where it has soaked the insulation underneath, with instruments, tests and small cuts into the roof, and checking that a roof is still fit to carry its loads.
4
Milestones achieved, from 1970s to 2014.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1970s
Soil gauges move to roofs
A nuclear moisture meter sends fast neutrons into a material and counts the slow ones that bounce back, which have mostly struck hydrogen atoms, found in water but also in bitumen. Such gauges had measured water in soil and concrete since the 1950s, and a 1981 NBS review of roof moisture methods says their use to find wet roof areas began in the early 1970s. Readings are taken at the corners of a grid, often 10 by 10 ft (3 by 3 m) for nuclear meters and 5 by 5 ft (1.5 by 1.5 m) for one maker's capacitance meters, which sense the change water makes to an electric field. The review warns that wet spots smaller than the grid can be missed, that each roof needs its own dry reference reading, and that extra bitumen reads like extra water.
LessonA gauge that reads one spot at a time trades coverage for cost, and the grid sets the smallest leak it can find.
Credit
makers of soil gauges and the US Army Corps of Engineers' Waterways Experiment Station (WES), which tested them on soil; D. R. Jenkins, R. G. Mathey and L. I. Knab of NBS for the review
1975
Infrared scans at night
Wet insulation holds heat, so on a clear night the roof surface over it stays warmer than over dry insulation and shows up to a thermal camera. WES flew military reconnaissance aircraft with thermal scanners over Offutt Air Force Base in November 1974 and over nearly 250 buildings at Pease and Offutt bases in May 1976, and found the difference between wet and dry areas greatest between about 10 pm and midnight. From 1975 the Army's Cold Regions Research and Engineering Laboratory (CRREL) led surveys of many roofs with hand-held cameras, and its engineers Wayne Tobiasson and Charles Korhonen wrote up how to run them. NBS's 1981 review recommends cutting cores out of the roof at selected points to confirm what instruments show. ASTM's practice C1153, whose earliest edition on ASTM's store is from 1997, now sets conditions for night-time infrared surveys from the roof or the air, including checking the results by cutting into the roof.
LessonRoof details, gravel and reflected sky also make warm and cool patches, so an infrared picture is a map of places to cut, not proof of water.
Credit
CRREL (Wayne Tobiasson, Charles Korhonen) and WES (L. E. Link Jr.), US Army Corps of Engineers
2007
Big roofs checked twice yearly
On 28 January 2006 the roof of an exhibition hall at the Katowice International Fair in Poland fell in during a pigeon fanciers' show, killing at least 65 people and injuring about 140, possibly under heavy snow. Canadian Consulting Engineer reported that the roof was said to carry up to 45 cm of icy snow and that Poland's prime minister promised to make clearing ice and snow off roofs mandatory. Poland's Act of 10 May 2007, in force on 20 June 2007, made owners inspect buildings with a footprint over 2,000 m² and other structures with a roof over 1,000 m² at least twice a year, by 31 May and by 30 November, and notify the building authority. A current guide by the Polish law firm KG Legal says the rule still applies.
LessonSnow on a large flat roof is a load that has to be checked every winter, not only designed for once.
amp.insurancejournal.comcanadianconsultingengineer.comapi.sejm.gov.plkglegal.pl
Credit
Poland's parliament (Sejm)
2014
Leaks traced by current
Electronic leak detection finds holes in a membrane by putting a voltage across it: a membrane over a conductive deck passes current only where there is a breach. In low-voltage "vector mapping" a technician wets the roof inside a perimeter wire, reads the voltage between two hand-held probes and follows it to the hole. In high-voltage testing a brass brush charged to 15,000–40,000 V DC sparks through any hole in a dry membrane. Chad Herrick of Detec Systems, a leak-detection firm, dates vector mapping to Germany in the 1970s; the trade magazine Waterproof says Europeans began experimenting in the 1980s and developed low-voltage testing in the early 1990s, and that International Leak Detection, founded in 2001, brought it to North America. ASTM's guide D7877, in its 2014 edition, describes the methods for checking new membranes and finding leaks in old ones; it needs a conductive layer right under the membrane, so roofs with foam insulation there need a conductive sheet added.
Credit
a German electrical engineer, unnamed in the sources read; International Leak Detection; ASTM Committee D08
Watch for
Sensors inside the insulation
VILPE, a Finnish maker of roof vents and fasteners, sells VILPE Sense, battery-powered wireless humidity sensors fixed inside the insulation of a low-slope roof, about one per 200 sq ft (19 m²), that report to an online moisture map, with batteries it says last at least 10 years. Its January 2026 US brochure says the system "outperforms" electronic leak detection, which it describes as finding membrane punctures only and needing manual inspection, cites "recent surveys of US roofing professionals" for the claim that early detection eliminates 90% of repair costs per leak, and prices the system at $0.90 per sq ft in its own example. SMT Research of Canada sells a different design, a wired grid of moisture-sensing tape laid under the insulation.
Achieved whenAn outside party, such as an insurer, a test lab or a building owner, publishes how many leaks the sensors found and missed, on real roofs or a test deck, compared with electronic leak detection or cores.
Claimed by
VILPE, January 2026
Open
01
Wet insulation answer key
An open set of thermal images of roof sections built on the ground, with the water content of every insulation board known by weighing. About a dozen 4 by 8 ft (1.2 by 2.4 m) mock-ups of common flat-roof build-ups, such as membrane over polyiso foam, wood fiber or mineral wool on a steel deck, stand on low frames in an open yard; some boards are wetted by measured amounts, and cameras on a fixed mast image them through the night. A scoring script lets anyone test a model that marks wet areas.
The briefCredit · unclaimed02
Leak sensors on test decks
A side-by-side test of roof leak sensors on identical mock roof sections at ground level: commercial systems, such as wireless humidity sensors and wired moisture-tape grids, and a do-it-yourself grid of cheap resistive and capacitive sensors on ESP32 microcontroller boards. A timed pump drips measured amounts of water through holes planted in the membranes on a schedule the people reading the sensors do not know.
The briefCredit · unclaimed
Open 01 · the brief
Wet insulation answer key
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open set of thermal images of roof sections built on the ground, with the water content of every insulation board known by weighing. About a dozen 4 by 8 ft (1.2 by 2.4 m) mock-ups of common flat-roof build-ups, such as membrane over polyiso foam, wood fiber or mineral wool on a steel deck, stand on low frames in an open yard; some boards are wetted by measured amounts, and cameras on a fixed mast image them through the night. A scoring script lets anyone test a model that marks wet areas.
Why it is still open
NBS's 1981 review and ASTM C1153 both call for cores to confirm what infrared shows, because details and surface differences mimic wet spots. Laboratory work with wetted roof specimens is old: a 1982 ASTM symposium paper measured the smallest moisture content infrared could detect in prepared specimens, but released no images. The open thermal roof data found are about other things: the TBBR set on Zenodo (2022) holds 2,848 drone thermal images of rooftops in Karlsruhe, Germany, gathered to label thermal bridges (places where heat leaks through the structure), not water. A 2023 Czech Technical University paper used a drone and a U-Net model on a flat PVC roof; its 95% accuracy is for sorting roof surfaces such as membrane and windows, it gives no count of wet areas checked against cores, and it publishes no data. GitHub searches found only a 2026 course project using made-up roof water data.
Built with what exists
Insulation boards, cover boards, membrane offcuts and steel deck sheet from a roofing supplier; a platform scale; a radiometric thermal camera such as a FLIR E-series, or a FLIR Lepton module on a Raspberry Pi; a small weather station; Python, OpenCV and an open segmentation model such as U-Net.
First step
Build two mock-ups, wet one board in one of them by a weighed amount, and image both through one clear night.
Done looks like
At least 12 mock-ups imaged on at least 10 nights, about 5,000 images labeled with each board's water content by weight, released under an open license; and a baseline model scored on boards it has not seen, with the share of wet boards found and the number of dry boards flagged both published.
Open 02 · the brief
Leak sensors on test decks
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A side-by-side test of roof leak sensors on identical mock roof sections at ground level: commercial systems, such as wireless humidity sensors and wired moisture-tape grids, and a do-it-yourself grid of cheap resistive and capacitive sensors on ESP32 microcontroller boards. A timed pump drips measured amounts of water through holes planted in the membranes on a schedule the people reading the sensors do not know.
Why it is still open
VILPE's comparison of its system with other leak detection is a table of its own, with no test conditions, and SMT's literature describes how its grid works but cites no outside test. ASTM's roofing committee is drafting a guide (work item WK97239) that will describe the kinds of continuous roof leak monitoring and their limits, but a guide does not test products. Searches in November 2026 found patent filings for moisture-sensing roofs and makers' literature, but no published side-by-side test of current roof leak sensors.
Built with what exists
Plywood or steel deck panels, insulation, cover board and membrane; sensor kits bought or lent by makers; ESP32 boards with capacitive moisture probes and two-wire resistive tape; a peristaltic pump on a timer for blind leaks; a logging dashboard such as Home Assistant or Grafana.
First step
Build one 4 by 8 ft section with a home-made sensor grid and log its readings while dripping 1 liter (about a quart) through a planted hole.
Done looks like
At least 40 blind leaks across at least four systems, with a published tally for each system of leaks found, hours to first alert, false alarms per week and how closely it located the wet area.