This work installs and replaces the appliances that heat a building's water, tank or tankless, gas, electric or heat pump, and the fixtures people use every day: toilets, urinals, faucets and showers.

7

Milestones achieved, from 1596 to 2024.

2

To watch for: announced, not yet confirmed outside.

3

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1596

    A flushing toilet described

    Sir John Harington, a godson of Queen Elizabeth I, published A New Discourse of a Stale Subject, Called the Metamorphosis of Ajax in 1596. Its labeled drawing shows a water closet: a cistern above sends water through the pan, which he calls the stool pot, and out through a sluice to a vault below. The University of Victoria's Internet Shakespeare Editions calls it "an idea before its time", because people of the period had little reason to care about sanitation while the link to disease was poorly understood.

    LessonA better fixture does not spread until people see a reason to want it.

    internetshakespeare.uvic.ca

    Credit

    Sir John Harington

  2. 1868

    Gas heats the water

    The Science Museum in London holds what it describes as the "original gas geyser invented by B.W. Maughan in 1868" (object 1913-77); a geyser heats water over a gas flame as the water flows through it. In Pittsburgh, Edwin Ruud of the Fuel Gas and Manufacturing Company patented a water heater in 1890 in which a rod that lengthens and shortens with the water's temperature turns the gas valve up and down, so the burner holds the water at a set heat by itself (US patent 443,797, filed 21 June 1890, granted 30 December 1890).

    collection.sciencemuseumgroup.org.ukpatents.google.com

    Credit

    B. W. Maughan; Edwin Ruud

  3. 1980

    Warm-water seats in Japan

    TOTO launched the Washlet, an electric toilet seat that washes the user with warm water, in June 1980. By TOTO's count, shipments passed 70 million in November 2025, and sales outside Japan were more than 30% of the total in 2024. Japan's Cabinet Office found warm-water washing toilet seats in 82.5% of households of two or more people at the end of March 2026.

    toto.comesri.cao.go.jp

    Credit

    TOTO Ltd

  4. 2003

    Toilets flushed until failure

    The US Energy Policy Act of 1992 required that, with a few exceptions, toilets sold from 1994 flush with no more than 1.6 gallons (6.0 liters), where 3.5 gallons (13 liters) had been usual in the 1980s. Many makers only fitted their old models with parts that sent about half the tank into the bowl. Customers flushed twice, home builders got callbacks, and some owners fitted flappers made for old toilets to get more water. In 2002, 22 organizations in Canada and the US paid for a test called Maximum Performance (MaP), which loads a toilet with soybean paste and paper in 50-gram steps until it no longer clears the bowl; its first report, on 44 toilets, came out in December 2003. MaP says more than 5,000 models have been tested since, and that its pass mark of 350 grams is now part of EPA's WaterSense label and the ASME/CSA standard for toilets.

    LessonA rule that cuts water use needs a performance test beside it, or people flush twice and lose the savings.

    map-testing.commap-testing.com

    Credit

    the 22 funding organizations; John Koeller and Bill Gauley, the program's contacts

  5. 2003

    Heaters that ignore spilled gasoline

    From 1 July 2003, US makers built their 30-, 40- and 50-gallon gas water heaters with atmospheric vents to the standard ANSI Z21.10.1-2001, which requires that gasoline spilled in the room must not catch fire outside the heater. Each maker used a flame arrestor, a plate with many small holes or louvers that lets air in to the burner but stops a flame from passing back out, so the vapors burn inside the combustion chamber. Because arrestors could clog, the makers also wrote a lint, dust and oil test. Contractor magazine reported that the change added $60 to $100 to a heater's wholesale price.

    LessonWhen people keep storing gasoline beside an open flame, the lasting fix is in the appliance, not in the warning.

    contractormag.com

    Credit

    US water heater makers, among them A. O. Smith, American Water Heater, Bradford White and Rheem; tests at the CSA laboratory in Cleveland

  6. 2006

    A bypassed safety device kills

    On 28 August 2006 Japan's Ministry of Economy, Trade and Industry (METI) ordered Paloma Industries to recall seven models of indoor gas water heaters with exhaust fans, which had caused 28 cases of carbon monoxide poisoning and 21 deaths between 1985 and 2005. Japan's product safety agency, NITE, said the heaters' control box, a safety device, often failed soon after purchase because of a cracked solder joint, so the gas would not light, and that the design made the box easy to bypass. An altered heater kept burning if its exhaust fan lost power, filling the room with carbon monoxide. More than 200 altered units were thought to be installed, and NITE said Paloma knew of the alterations but did not warn users.

    LessonA safety device that fails often will be bypassed in the field, so it must be reliable and hard to defeat.

    japantimes.co.jpnite.go.jp

    Credit

    METI; NITE

  7. 2024

    Heat pumps required from 2029

    A heat pump water heater moves heat from the surrounding air into the tank instead of making it with a flame or a heating element. The US Department of Energy (DOE) published a rule on 6 May 2024 under which, from 6 May 2029, most electric tank water heaters of 20 to 55 gallons must meet a level reached today only with heat pumps. Small, short "lowboy" heaters of 20 to 35 gallons keep a lower standard, partly because a heat pump unit often does not fit where they are installed. DOE projected that without the rule only 12% of these heaters sold in 2030 would be heat pumps. A second rule, of 26 December 2024, for gas tankless water heaters went the other way: Congress voided it under the Congressional Review Act, and DOE withdrew it on 20 May 2025.

    LessonA standard is not settled until its compliance date arrives, and it can be undone before then.

    federalregister.govenergy.gov

    Credit

    US DOE; US Congress

Watch for

  1. Toilets that grade stool

    TOTO says its NEOREST LS-W and AS-W toilets, sold in Japan from August 2025, scan stool as it falls and measure its shape, color and amount for a phone app. Kohler sells Dekoda, a $599 camera that clips to the rim of the bowl, launched in October 2025; Kohler says it reports on gut health and hydration and alerts the user when blood is present. Throne says its AI matched five gastroenterologists in rating 278 beta-testers' stool photos on the Bristol scale, a seven-type scale of stool form, with 89.6% exact agreement on the most common type, in a study presented at the American College of Gastroenterology meeting in October 2026. A TOTO prototype, tested by University of Tsukuba doctors together with two TOTO researchers on 305 samples from 38 people, agreed only moderately with the users' own ratings (a kappa score of 0.55, where 1 is perfect agreement).

    Achieved whenA group with no tie to the maker publishes the accuracy of a unit on sale against blinded raters.

    toto.comkohlerhealth.competapixel.cominsider.fitt.cojstage.jst.go.jp

    Claimed by

    TOTO, August 2025; Kohler, October 2025; Throne, October 2026

  2. Water labels on UK taps

    The UK government says it will bring in a mandatory water efficiency label for products such as showers and toilets, with the regulations to be laid before Parliament in 2026. It estimates the label would save consumers £56 million on water bills and £69 million on energy bills over 10 years. On 12 January 2026 the UK notified the European Commission of draft Mandatory Water Efficiency Labelling Regulations 2026 for Northern Ireland, covering taps, showers, toilets and urinals. In the government's July 2026 update the regulations were still "in development".

    Achieved whenThe regulations are in force and the labels appear where the products are sold.

    gov.uktechnical-regulation-information-system.ec.europa.eu

    Claimed by

    UK Department for Environment, Food and Rural Affairs (Defra), plan updated July 2026

Open

  1. 01

    Grade water heater photos

    A public set of photos of installed tank water heaters, each checked by two plumbing inspectors against a short list taken from the model plumbing codes: a discharge pipe on the temperature-and-pressure relief valve (the valve that opens if the tank gets too hot or too full of pressure), run full size to a safe place; an expansion tank where one is required; a gas vent connector that rises and is joined; earthquake straps where required; a drain pan where required; a gas shutoff and a sediment trap (a short capped pipe that catches debris before the gas valve). Then publish how well vision models find each fault.

    The brief
    Credit · unclaimed
  2. 02

    Screen homes for heat pumps

    A screener that takes a few phone photos and tape measurements of the space around an existing water heater, the electrical panel and the nearest drain, and says whether a heat pump water heater will fit there, needs the heater moved, or should not be fitted, with the reason. Score it against the decisions of installers who visited the same homes.

    The brief
    Credit · unclaimed
  3. 03

    Test toilets that read stool

    An outside bench test of stool-reading toilet devices on sale, such as Kohler's Dekoda and Throne's sensor. Use synthetic stool made from soybean paste, the material MaP uses to test toilets, pressed in molds into each of the seven Bristol types, plus red-dyed samples to see whether a blood alert fires on dye. No people take part.

    The brief
    Credit · unclaimed

Open 01 · the brief

Grade water heater photos

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public set of photos of installed tank water heaters, each checked by two plumbing inspectors against a short list taken from the model plumbing codes: a discharge pipe on the temperature-and-pressure relief valve (the valve that opens if the tank gets too hot or too full of pressure), run full size to a safe place; an expansion tank where one is required; a gas vent connector that rises and is joined; earthquake straps where required; a drain pan where required; a gas shutoff and a sediment trap (a short capped pipe that catches debris before the gas valve). Then publish how well vision models find each fault.

Why it is still open

Shipshape's app reads water heater data plates from photos and says it flags "improper installation" and "code violations", but it gives no accuracy figures and does not say which codes it checks against. Home inspection software has added general photo checkers, such as Inspection Support's Defect Detector of September 2026, which flags cracks, water damage and mold and drafts report comments, again with no accuracy figures. This research found no public labeled set of installations; a GitHub search for water heater projects turned up only controllers.

shipshape.aihelp.inspectionsupport.com

Built with what exists

Phone photos from plumbing training labs and from home inspection reports used with the owners' permission; the water heater chapters of the International Plumbing Code and the Uniform Plumbing Code for the list; Label Studio for labeling; open vision-language models and at least one commercial model to be scored.

  1. First step

    Write the checklist from the codes, photograph 50 water heaters at a plumbing training center, and have one inspector label them.

  2. Done looks like

    At least 1,000 labeled photos from at least three regions released under an open license, the two inspectors' agreement on each item published, and for each item the share of real faults each of three models finds and the share of its flags that are false.

Open 02 · the brief

Screen homes for heat pumps

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A screener that takes a few phone photos and tape measurements of the space around an existing water heater, the electrical panel and the nearest drain, and says whether a heat pump water heater will fit there, needs the heater moved, or should not be fitted, with the reason. Score it against the decisions of installers who visited the same homes.

Why it is still open

In a survey for the Northwest Energy Efficiency Alliance (NEEA), published in 2023, space was the hardest barrier: when space was insufficient, 50% of installers said they would likely recommend against a heat pump water heater. The report recommended "a realistic decision tree or screening tool" for installers. DOE's 2024 rule kept a lower standard for lowboy heaters partly because heat pump units often do not fit where those go. The Department of Energy's 2024 permitting and inspection checklist, written by the New Buildings Institute, sets out the space rules on paper, such as a room of about 450 cubic feet with 6 inches of clearance around the unit. Photo tools such as Shipshape read data plates and estimate age but publish no fit test, and this research found no screener scored against site visits.

neea.orgbsesc.energy.govfederalregister.gov

Built with what exists

A phone camera and tape measure; the clearances and minimum room volumes in makers' installation manuals; NEEA's list of challenging installations as the rule set; an AI model that reads photos and fills in the checklist; site-visit outcomes from a utility rebate program for the answer key.

  1. First step

    Turn NEEA's list and three makers' manuals into a checklist, and run it on 20 homes where installers have already decided.

  2. Done looks like

    200 homes screened before an installer's visit, with the published share of homes where the screener's call matched the installer's, and every mismatch explained.

Open 03 · the brief

Test toilets that read stool

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An outside bench test of stool-reading toilet devices on sale, such as Kohler's Dekoda and Throne's sensor. Use synthetic stool made from soybean paste, the material MaP uses to test toilets, pressed in molds into each of the seven Bristol types, plus red-dyed samples to see whether a blood alert fires on dye. No people take part.

Why it is still open

The accuracy figures published so far come from the makers or include them. Throne's study used its own beta-testers' photos, the TOTO prototype paper has TOTO researchers among its authors, and Kohler's launch material gives no accuracy figures. This research found no test of a unit on sale by a group with no tie to its maker.

insider.fitt.cojstage.jst.go.jppetapixel.com

Built with what exists

Soybean paste test media from MaP's supplier, Gauley Associates; 3D-printed molds for the seven forms; a standard toilet; the devices and their apps; three raters who name each sample's type from photos without knowing the intended type.

  1. First step

    Make 10 samples each of types 1, 4 and 7 and check that three raters name the intended type from photos.

  2. Done looks like

    140 samples, 20 of each type, run through each device, with a published table of each device's answer against the intended type, the share it gets exactly right and within one type, and its false alarm rate on dyed samples.