BRENNEN

Industries / Construction and property / Commercial and residential construction / Plumbing

Finding leaks

Finding leaks is the work of locating water that escapes from pipes, fittings and appliances inside a building, often hidden in a wall or under a floor, before or after it does damage.

6

Milestones achieved, from 1873 to 2026.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1873

    A meter that finds waste

    After 1857 Liverpool's water supply became restricted and intermittent, mainly because of waste through defective pipes and fittings. George Frederick Deacon, appointed the city's Borough and Water Engineer in 1871, wanted something better than inspecting house after house, and in 1873 invented a waste-water meter that measured the water flowing into a district so leaks could be localized. On the advice of the engineer Frederick Bramwell, Liverpool fitted it throughout its supply and restored a constant supply, by Deacon's 1909 obituaries collected by Grace's Guide.

    LessonMeasuring the flow into an area finds waste faster than inspecting every house.

    gracesguide.co.uk

    Credit

    George Frederick Deacon

  2. 1976

    Insurers count water damage

    In 1976 Swedish home and property insurers had 63,800 water damage claims, estimated to cost them about 300 million kronor. Their building repair committee (FBK) had its inspectors fill in a form, written with the plumbing contractors' association, for every water damage they examined from 15 October 1976 to 15 January 1977, about 4,300 cases, and estimated that 40 to 50% came from neglected maintenance. The survey became Sweden's yearly Water Damage Report. The 2025 edition, built from 28,183 inspected damages, attributes 57% to pipe systems, 28% to appliances and other equipment and 15% to bathroom waterproofing, and found that 98% of the damages happened where no leak-protection device was fitted.

    LessonCounting the causes of leaks every year shows where rules and training need to change.

    vattenskadecentrum.sevattenskadecentrum.se

    Credit

    Försäkringsbolagens Byggreparationskommitté; Rörfirmornas Riksförbund; Vattenskadecentrum (the insurers Dina, Folksam, If, Länsförsäkringar and Trygg-Hansa with trade bodies)

  3. 2019

    A lab tests leak monitors

    Home leak monitors measure the water a house uses and send an alert, or close a valve, when flow looks like a leak. For the Southern Nevada Water Authority, Utah State University's Utah Water Research Laboratory tested five of them in May 2019 (Streamlabs, Buoy, Phyn, Flo by Moen and Flume) against water weighed on a scale, at flows from 15 down to 0.25 gallons (about 0.95 liters) a minute. Buoy, Phyn and Flume were the most accurate. At the lowest flow one first-generation Flo read zero, and clamp-on Streamlabs monitors read from 0% to 284% of the true flow, depending on the pipe material.

    LessonA leak monitor must first be shown to measure small flows, and some could not.

    cdn.shopify.com

    Credit

    Steven L. Barfuss, Tyler Ashby and Adam Pack (Utah Water Research Laboratory); Southern Nevada Water Authority

  4. 2020

    Shutoffs and fewer claims

    A smart water shutoff is a valve on the main supply pipe that measures flow and closes when it detects a leak. LexisNexis Risk Solutions, a data firm that serves insurers, compared 2,306 US homes that installed the Flo by Moen Smart Water Shutoff with nearby homes that did not. In the year after installation, water claims in the Flo homes fell 96% and their average cost 72%, while claims in the other homes rose 10%. LexisNexis called this early evidence of a correlation, not proof of cause.

    risk.lexisnexis.com

    Credit

    LexisNexis Risk Solutions; Flo Technologies

  5. 2022

    Shutoffs tested drop by drop

    RISE, Sweden's state research institute, bought eight whole-house water shutoffs sold in Sweden in 2021 and tested them for the insurer Länsförsäkringar under its test method SP 5314, reporting in February 2022. At a drip of 15 to 18 milliliters an hour, about one or two drops a minute, run after each device had been installed for at least three days, four of the eight gave a warning or an alarm and one, the Nordia NT100, shut off the water; Phyn Plus sent a warning by app and text message, while the GROHE Sense Guard and three others gave no signal. The same month Säker Vatten announced that the trade and the insurers had agreed on the method as the test for type approval of such devices, with yearly checks by a third party.

    LessonHalf the devices sold to stop leaks missed a slow drip, so a leak device needs a common test with a pass mark.

    lansforsakringar.semynewsdesk.com

    Credit

    RISE (report by Daniel Ryde); Länsförsäkringar's research fund, which paid for the test method; Säker Vatten

  6. 2026

    Swedish kitchens get leak sensors

    Säker Vatten, which writes Sweden's industry rules for plumbing and authorizes about 2,200 plumbing firms, made new rules (2026:1) for work started from 1 January 2026. Every kitchen must now have active protection against water damage: a moisture sensor connected to a leak breaker, a water shutoff or a water alarm, with products approved under a new test method. Säker Vatten says work done to its rules meets the national building authority's requirement for workmanlike installation, a condition for the installation to be insurable.

    sakervatten.sesakervatten.se

    Credit

    Säker Vatten

Watch for

  1. Moen's 81% claim

    Moen says that in a case study with a major national US home insurer, joint customers who installed its Flo leak detection had 81% fewer claims and 85% lower claim costs. The insurer, the number of homes and the period are not given, and a page describing the study calls it "limited".

    Achieved whenThe insurer or an outside analyst publishes the number of homes, the comparison group and the claim counts before and after installation.

    insurance-canada.cainsurancebusinessmag.com

    Claimed by

    Moen, in an article by Jerry Fairborn of Moen Canada, January 2026

Open

  1. 01

    Drip tests beyond Sweden

    An open bench test of the home leak monitors and automatic shutoffs sold in North America and Britain, run to the test points of RISE's Swedish method: a drip of about 15 milliliters an hour, a steady flow of 0.1 liters a second for an hour, and a burst. Add what that method leaves out: a sweep of leak rates from about 5 to 500 milliliters a minute to find the smallest leak each device reports, and a script that replays normal use, such as toilet refills and a running tap, to count false alarms. A scale weighs the water that escapes.

    The brief
    Credit · unclaimed
  2. 02

    Locate leaks behind walls

    A mock wall in which leaks of known size are opened at known points on PEX and copper supply lines behind drywall and tile. Contact microphones on the wall surface and on the exposed pipe at the manifold record each case. Release the recordings and a model that says whether a leak is running and which section of wall it is in.

    The brief
    Credit · unclaimed

Open 01 · the brief

Drip tests beyond Sweden

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open bench test of the home leak monitors and automatic shutoffs sold in North America and Britain, run to the test points of RISE's Swedish method: a drip of about 15 milliliters an hour, a steady flow of 0.1 liters a second for an hour, and a burst. Add what that method leaves out: a sweep of leak rates from about 5 to 500 milliliters a minute to find the smallest leak each device reports, and a script that replays normal use, such as toilet refills and a running tap, to count false alarms. A scale weighs the water that escapes.

Why it is still open

RISE's 2022 comparison covered eight devices bought in Sweden in 2021 and ran its drip test at one rate; of the monitors common in North America, only Phyn Plus was in it. Utah State's 2019 test for the Southern Nevada Water Authority measured flow accuracy only down to 0.25 gallons (about 950 milliliters) a minute and did not test alerts, and LexisNexis measured insurance claims, not detection. This research found no published drip test of Flo by Moen, Flume or LeakBot devices.

lansforsakringar.secdn.shopify.com

Built with what exists

Copper or PEX pipe on a bench fed from an ordinary household tap; needle valves; a kitchen scale read by a logging script; five or more commercial monitors, such as Phyn, Flo by Moen and Flume; a Raspberry Pi to log the time of each alert.

  1. First step

    Build the rig with one monitor, calibrate the needle valve with the scale and a stopwatch, and run a 24-hour test at RISE's drip rate of about 15 milliliters an hour.

  2. Done looks like

    A published table giving, for each of at least five devices, its result at each of RISE's test points, the smallest leak it reported within 24 hours, and its false alarms over 100 replayed normal-use events, with the raw logs released.

Open 02 · the brief

Locate leaks behind walls

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A mock wall in which leaks of known size are opened at known points on PEX and copper supply lines behind drywall and tile. Contact microphones on the wall surface and on the exposed pipe at the manifold record each case. Release the recordings and a model that says whether a leak is running and which section of wall it is in.

Why it is still open

Hearing a leak behind a wall has been shown; placing it has not. Michael Hasselbeck of MicroPhonon described in a November 2025 preprint a battery sensor, with its design files on GitHub, that detected a simulated leak behind drywall across up to five studs. It reports only whether a leak is present, the paper notes that locating leaks indoors by triangulation is hard because sound echoes, and all its tests are the author's own. The open leak-sound datasets found are for buried pipes, such as Aghashahi and colleagues' laboratory testbed of PVC pipe and a 2026 set recorded in Ho Chi Minh City streets. The open damp-case set proposed in real-estate.md pairs photos and moisture readings with causes once water shows on a surface; this item finds the leak before a stain appears.

arxiv.orgdata.mendeley.comgithub.com

Built with what exists

A stud wall section with drywall and tile; PEX and copper pipe on a bench water line; needle valves; piezoelectric contact microphones and a USB audio interface; MicroPhonon's published design as a detection baseline; Python with an open audio classifier.

  1. First step

    Build a 2.4-meter (8-foot) wall section with one PEX line and two valve-controlled leak points, and record an hour each at three leak rates and at no flow.

  2. Done looks like

    At least 20 hours of labeled recordings released under an open license, and a blind test of 30 leaks and 30 no-leak periods with published detection accuracy and the share of leaks placed in the right 60-centimeter (2-foot) section of wall.