BRENNEN

Industries / Construction and property / Commercial and residential construction / Plumbing

Gas lines

Gas fitters run and test the pipes that carry natural gas or propane from the meter to the stove, furnace, water heater and dryer, so that the gas reaches each appliance at the right pressure and does not leak.

5

Milestones achieved, from 1794 to 2015.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1794

    Gas lights a house

    William Murdoch, a Scottish engineer working in Cornwall for the steam-engine makers Boulton and Watt, experimented with piped gas for lighting from 1792. In 1794 he set up a large retort, a closed iron vessel for heating coal, in the back yard of his house on Cross Street, Redruth, and piped the gas it gave off to light his living room. Historic England's listing calls it the first house in the world lit by piped gas and the foundation of today's gas industry.

    britishlistedbuildings.co.uk

    Credit

    William Murdoch

  2. 1983

    Meters that shut off gas

    In 1983 the meter maker now called Azbil Kimmon began full-scale production of a city gas meter with a microcomputer that cuts off the gas by itself after an earthquake of intensity 5 or more on the Japanese scale. A 1986 model added a pressure-sensitive quake sensor and self-checks, and a propane version followed in 1987 after the Ministry of International Trade and Industry decided that safety devices were the best defense against propane accidents. Japan's LP Gas Association, citing the Ministry of Economy, Trade and Industry, says accidents involving household propane users peaked at 793 in 1979 and fell to less than a tenth of that over the next 10 years as such meters and other safety devices spread. It says nearly all gas meters in Japan now shut off by themselves on a leak, a quake or unusually long use.

    LessonA safety device built into the meter that every home already has reached all users at once, without asking each household to act.

    ak.azbil.comj-lpgas.gr.jp

    Credit

    Azbil Kimmon; Japan's Ministry of International Trade and Industry

  3. 1988

    Flexible tubing meets lightning

    Corrugated stainless steel tubing (CSST) is thin-walled, flexible gas pipe in a plastic jacket, quicker to run through a house than threaded black iron pipe. NFPA 54, the US National Fuel Gas Code, first allowed it in 1988. Lightning striking a house or near it can arc through the thin wall and start a fire. A class action in Arkansas against four makers settled in 2006 for up to about $29 million, the makers added bonding, a heavy copper wire tying the tubing to the building's electrical ground, to their instructions in August 2006, and NFPA 54 required it from its 2009 edition. In 2019 Bryan Haslam and Thomas Eagar ran thousands of lightning simulations and found that, for strikes above the median current, bonding never prevented a hole in the tubing.

    LessonA pipe approved because it is quick to install can carry a risk that shows up only years later, and a fix backed by a few of the makers' own simulations may not hold.

    ecmweb.comlink.springer.com

    Credit

    NFPA; the CSST makers; Bryan Haslam and Thomas Eagar (Fire Technology, 2019)

  4. 2009

    A register for gas fitters

    Great Britain's Gas Safety (Installation and Use) Regulations 1998 forbid any business to do gas work unless it belongs to a class of persons approved by the Health and Safety Executive (HSE), and make it an offense to pretend to belong. Since 1 April 2009 that class has been the Gas Safe Register: its engineers carry an ID card listing the appliances they are qualified to work on, and its inspectors check their work. It replaced CORGI registration, which ran for more than 17 years, a period in which, HSE says, domestic gas deaths fell significantly.

    legislation.gov.ukhse.gov.uk

    Credit

    the Health and Safety Executive; Gas Safe Register

  5. 2015

    An illegal tap explodes

    On 26 March 2015 a gas explosion destroyed 121 Second Avenue in Manhattan's East Village, killing Nicholas Figueroa, 23, and Moises Locon, 26, and seriously injuring 13 others. In November 2019 a jury convicted the owner, Maria Hrynenko, the plumber Athanasios Ioannidis and the contractor Dilber Kukic of manslaughter for building an illegal gas delivery system; prosecutors said Ioannidis had no license and the owner urged the work done before the utility, Con Edison, could inspect. Under New York City's Local Law 152 of 2016, a licensed master plumber must now inspect the exposed gas piping in every building other than one- and two-family homes at least once every four years, checking for leaks with a portable gas detector and for illegal connections.

    LessonGas work hidden from the utility and the inspector is the most dangerous kind, so the city now sends a licensed inspector on a fixed schedule.

    nyc.govamp.insurancejournal.comnyc.gov

    Credit

    Manhattan District Attorney's Office; New York City Council and Department of Buildings

Watch for

  1. Gas alarms in NYC homes

    New York City's Local Law 157 of 2016 requires natural gas alarms, listed to the UL 1484 standard, in homes with gas appliances. A 2025 amendment moved the deadline from 1 May 2025 to 1 January 2027, with an extension to 2029 if the Department of Buildings found fewer than four makers of battery-powered alarms. In October 2026 a vice president of the alarm maker Nexelec wrote that the department had confirmed the 2027 date.

    Achieved whenThe city or an outside group publishes, after the deadline, how many covered homes have working alarms and how many real leaks the alarms reported.

    nyc.govmannpublications.com

    Claimed by

    New York City Council (Int. No. 1281-A, June 2025); Nexelec, October 2026

Open

  1. 01

    What gas inspections find

    A public table of what New York City's periodic gas piping inspections found, building by building: gas leaks, worn or corroded piping, illegal connections and other code violations, and how long owners took to fix them, joined to the city's open data on each building's age, type and borough.

    The brief
    Credit · unclaimed
  2. 02

    Count explosions past the meter

    An open, coded table of gas fires and explosions that began on a building's own piping or appliances, built from fire investigation reports and court records: date, place, gas (natural gas or propane), where the gas escaped (connector, piping, appliance, illegal tap) and whether anyone had worked on the gas system shortly before.

    The brief
    Credit · unclaimed

Open 01 · the brief

What gas inspections find

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of what New York City's periodic gas piping inspections found, building by building: gas leaks, worn or corroded piping, illegal connections and other code violations, and how long owners took to fix them, joined to the city's open data on each building's age, type and borough.

Why it is still open

Under Local Law 152 each inspection report must list gas leaks, worn parts, non-code installations and illegal connections, and owners must certify to the Department of Buildings that the conditions were fixed. But the department's public spreadsheet of about 280,000 properties lists only each building's address, class, sub-cycle and deadline, and this research found no published count of what the inspections found. The department has published an analysis of the gas utilities' referrals instead: from May 2016 to September 2020 it received about 820 notices a month from Con Edison and National Grid, 10% of them judged high risk, and illegal piping and illegal bypasses with flexible hose made up 80% of the high-risk kinds.

nyc.govnyc.govnyc.gov

Built with what exists

Requests under New York's Freedom of Information Law for the inspection certifications and reports; a PDF text extractor and a general AI model to read the forms into fields, checked by hand on a sample; the city's PLUTO open data for building age and type; Python and SQLite.

  1. First step

    File a records request for one community district's first-cycle certifications, and read 20 of them into a table by hand to make the answer key.

  2. Done looks like

    Findings for at least 2,000 buildings from the first cycle (2020 to 2023), with every field checked against the forms on a random sample of 100 and the error rate published, and a table of leak and illegal-connection rates by building age, type and borough.

Open 02 · the brief

Count explosions past the meter

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open, coded table of gas fires and explosions that began on a building's own piping or appliances, built from fire investigation reports and court records: date, place, gas (natural gas or propane), where the gas escaped (connector, piping, appliance, illegal tap) and whether anyone had worked on the gas system shortly before.

Why it is still open

US federal pipeline rules stop at the outlet of the customer's meter, and a utility need only tell customers once, in writing, that it does not maintain their buried piping beyond it, so the federal record of gas incidents covers the utility's side. New York City's inspection law leaves out one- and two-family homes. New York City's analysis of utility notices counts hazards found, not fires and explosions, and Ontario's safety regulator, TSSA, publishes a yearly total of fuel incidents of all kinds, 3,128 in its 2025 fiscal year, on a page that does not list them one by one. This research found no public table of incidents on the building side.

law.cornell.edulaw.cornell.edutssa.orgnyc.gov

Built with what exists

Public fire investigation reports, court records and news archives to find incidents; a general AI model to pull fields from each report, checked by hand; a coding guide written with a retired fire investigator.

  1. First step

    Collect the 20 most recent house gas explosions reported in one state, find an official report for each, and code them by hand.

  2. Done looks like

    200 incidents from at least three states over 10 years, each with a cited source and a cause code checked independently by two people, with their rate of agreement and a table of the most common causes published.