Drains and vents
Drains carry used water out of a building by gravity, with a water-filled bend called a trap under each fixture to keep sewer air out, and vent pipes that let air in so rushing water does not suck the traps dry.
7
Milestones achieved, from 1775 to 2020.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1775
A water seal stops smells
On 11 November 1775 the Scottish watchmaker Alexander Cumming was granted UK patent number 1105, the first UK patent for a flushing water closet. It covered the shape of the pan, the way water entered it, and a "stink trap" built so that its contents emptied at every use; the UK National Archives describes his invention as centered on an S-shaped trap. A trap of this kind, a bend that stays full of water, still sits under every sink, bath and toilet to keep sewer air out of the room.
Credit
Alexander Cumming
1928
A national plumbing code
In 1921 US Commerce Secretary Herbert Hoover set up a building and housing division at the National Bureau of Standards (NBS). His Building Code Committee found that minimum plumbing requirements could not be settled from the local codes of the day, so NBS ran experiments on house drainage, and in 1928 the committee published Recommended Minimum Requirements for Plumbing, known as the Hoover Code. NIST, the successor to NBS, calls it the first plumbing code; it set 20 basic principles and minimum technical rules. In 1945 the International Association of Plumbing and Mechanical Officials (IAPMO), founded in 1926 by Los Angeles plumbing inspectors, published the Uniform Plumbing Code, at first used only in California.
LessonRules drawn from measured tests replaced rules drawn from opinion, which Hoover said had made plumbing costly and inconsistent from town to town.
Credit
Herbert Hoover; the committee's plumbing subcommittee, among them George C. Whipple, with NBS researcher Roy B. Hunter; IAPMO
1933
A motor clears roots
Samuel Blanc of Des Moines, Iowa, built a machine that spins a long steel cable with cutting blades on its end, to cut tree roots and other clogs out of sewer pipes from inside. Roto-Rooter dates the invention to 1933 and says Blanc patented it. He founded the Roto-Rooter Corporation in 1935 and licensed the machine to local operators, by Eric Peterson's 1988 history of the company, written at Michigan State University. The company, sold by Blanc's heirs to Chemed in 1980, says it is now the largest provider of plumbing and drain cleaning services in North America.
Credit
Samuel O. Blanc
1961
Joints without molten lead
Cast iron drain pipe was joined by packing oakum, a tarred fiber, into the hub (a widened socket at one end of each pipe) and pouring in molten lead. Until the late 1950s this caulked joint was the only way to join hub-and-spigot cast iron drain pipe, by the account of the Cast Iron Soil Pipe Institute (CISPI). Hubless, or "no-hub", pipe has plain ends joined by a rubber sleeve inside a stainless steel band that is clamped tight. CISPI counts roughly 1.5 billion no-hub couplings installed in North America since 1961.
Credit
CISPI's member foundries
2003
Dry traps spread SARS
By 15 April 2003, 321 residents of the Amoy Gardens housing estate in Hong Kong had caught SARS (severe acute respiratory syndrome), 41% of them in Block E. Hong Kong's Department of Health and eight other agencies found that most households cleaned their bathroom floors by mopping, so the U-shaped traps under the floor drains were likely dry. With the bathroom fan on, air from the soil stack, the vertical drain pipe serving the flats above and below, flowed back into the bathroom, and a cracked vent pipe was also found. A WHO consultation concluded in September 2003 that inadequate plumbing was likely a contributor to the spread of SARS in Hong Kong's residential buildings.
LessonA trap protects a home only while it holds water, so drains that are rarely used need a way to stay filled.
Credit
Hong Kong Department of Health; World Health Organization
2012
Less water, slower drains
Since 1994, US law has capped new home toilets at 1.6 gallons (6.0 liters) a flush, and by 2012 makers were selling models that use 1.0 or even 0.8 gallons. The Plumbing Efficiency Research Coalition (PERC), formed in 2009 by water-efficiency, code, contractor and manufacturer groups, tested from March to July 2012 how far waste travels along a long building drain, at American Standard's lab in Piscataway, New Jersey. Pipe slope, the brand of toilet paper and flush volume all mattered; how the toilet released its flush did not. At 0.8 gallons (3.0 liters) a flush performance changed sharply, and a 5-gallon (19-liter) clearing flush failed to clear the drain in 7 of 39 runs.
LessonCutting the water a fixture uses can leave waste stranded in long drains, so drains have to be tested along with the fixtures.
plumbingefficiencyresearchcoalition.orgplumbingefficiencyresearchcoalition.org
Credit
PERC (Alliance for Water Efficiency, IAPMO, International Code Council, Plumbing-Heating-Cooling Contractors National Association, Plumbing Manufacturers International, and from 2011 the American Society of Plumbing Engineers)
2020
Drain stacks carry a virus
Min Kang and 17 colleagues reported that nine people in three families caught COVID-19 in a Guangzhou high-rise, in three flats stacked one above another and linked by the drain pipes of their main bathrooms. They took 237 surface and air samples and released a tracer gas into bathrooms, which spread through the stacks and vents. On this circumstantial evidence they judged that virus carried in aerosols from the drains probably caused the outbreak, though they could not tell whether the flats' water seals had dried out.
Credit
Min Kang and colleagues (Annals of Internal Medicine, 2020)
Watch for
AI rates drain drawings
Cheng-Li Cheng and Yen Yu Lin of the National Taiwan University of Science and Technology trained a convolutional neural network, a kind of image-recognition model, on 500 plumbing riser diagrams (drawings of a building's vertical drain and vent pipes) to sort high-risk drainage systems from stable ones. They report a best accuracy of 76% on their own data.
Achieved whenAnother group tests the method on riser diagrams from other buildings, with each building's risk judged by measured pressures or inspection, and gets a similar accuracy.
Claimed by
Cheng and Lin, Building Services Engineering Research and Technology, August 2025
Open
01
Test old vent valves
A bench rig and a public test of air admittance valves (AAVs) taken out of houses. An AAV is a one-way valve that lets air into a drain when water rushing past would otherwise suck the traps dry, then closes by gravity to keep sewer air in; builders use one instead of running a vent pipe up through the roof. Measure the suction at which each valve opens and whether it seals against gentle back pressure, and record its brand, its age and where it was fitted. The valves are cleaned and disinfected first, and no live drain is involved.
The briefCredit · unclaimed02
Check drain riser drawings
A public test set of drain-waste-vent drawings, risers and isometrics, each with known code errors planted in it, such as a drain too small for its load, a fixture with no vent, or too little slope, and a score of how many of those errors an AI tool finds and names, set against two plans examiners.
The briefCredit · unclaimed
Open 01 · the brief
Test old vent valves
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A bench rig and a public test of air admittance valves (AAVs) taken out of houses. An AAV is a one-way valve that lets air into a drain when water rushing past would otherwise suck the traps dry, then closes by gravity to keep sewer air in; builders use one instead of running a vent pipe up through the roof. Measure the suction at which each valve opens and whether it seals against gentle back pressure, and record its brand, its age and where it was fitted. The valves are cleaned and disinfected first, and no live drain is involved.
Why it is still open
When AAV makers asked in 2003 to have the valves admitted to the Uniform Plumbing Code, IAPMO's technical committee and standards council refused. One maker cited four returns per million valves sold; a committee member said every mechanical device fails in time and a worn valve lets sewer gas into walls and attics; an engineer quoted in the same report called most failure stories hearsay. Neither side cited a test of used valves, and this research found none published since.
Built with what exists
A clear plastic pipe section with a valve socket; a low-cost digital differential pressure sensor read by an Arduino or Raspberry Pi; a small fan or shop vacuum with a bleed valve for suction; a hand pump for back pressure; soapy water to show leaks; the opening and sealing tests of ASSE 1051, the US product standard for individual and branch AAVs, as the pass marks.
First step
Ask five plumbing firms and a building-materials reuse store to keep the AAVs they remove on jobs, labeled with the year fitted, and build the rig around one new valve.
Done looks like
At least 50 used valves from at least three brands, aged 5 to 25 years, each tested twice, with a published table of opening suction, leak result and pass or fail by age and brand, and the same tests on 10 new valves as a control.
Open 02 · the brief
Check drain riser drawings
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public test set of drain-waste-vent drawings, risers and isometrics, each with known code errors planted in it, such as a drain too small for its load, a fixture with no vent, or too little slope, and a score of how many of those errors an AI tool finds and names, set against two plans examiners.
Why it is still open
Codes size drain pipes by fixture units, a load figure for each fixture that goes back to Roy Hunter's work at NBS. Cheng and Lin's 2025 model sorts riser diagrams into high and low risk at 76% accuracy but does not say which rule a drawing breaks. InspectMind sells an AI plan checker that it says finds drain loads that exceed pipe sizes, vent sizing errors and riser diagrams that disagree between floors, checked against the International Plumbing Code; its page gives no measured rate of errors found or missed. Free tools on GitHub size pipes straight from the code tables, such as a Revit add-in that sizes storm drains to the International Plumbing Code, or answer code questions with AI. The plan-review test proposed in engineering-and-architecture.md covers room sizes, window areas and fixture counts, not drain and vent sizing, and none of these tools has been scored on a common set of drawings with known errors.
Built with what exists
A general vision-language AI model, or an open one fine-tuned on one graphics chip (see the Note "One GPU to fine-tune"); drawings made in free CAD software such as LibreCAD, sized from the drain tables of the code in force; a script that counts errors found, missed and invented.
First step
Draw the drain and vent risers for 10 two-story, two-bathroom houses, plant three errors in each, and run one general AI model on them.
Done looks like
100 drawings with 300 planted errors, published under an open license, with the share of errors each AI tool finds and its false alarms, beside the scores of two certified plans examiners on the same set.