Industries / Industrial equipment and services / Industrial services / Painting and abrasive blasting
Inspection
Inspection is checking coating work as it is done and afterwards: how thick each coat is, whether pinholes let water through to the steel, how well the coat sticks, and whether the people checking are qualified.
5
Milestones achieved, from 1947 to 1998.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1947
A gauge for paint thickness
Elcometer, a British firm, says its first gauge, the Elco Meter, was developed in 1946 to measure plastic and paint on steel, went into production in 1947 and sold for £10.50, and it calls it the world's "first" coating thickness gauge, the quotation marks its own. Magnetic gauges of this kind became the base of the rules: the first edition of SSPC-PA 2, in 1973, was titled "Measurement of Dry Coating Thickness with Magnetic Gages." Elcometer dates its first transistor gauge to 1959 and its first digital one to 1978.
Credit
Elcometer, by its own account
1973
A rule for counting readings
SSPC, the Society for Protective Coatings, issued SSPC-PA 2 in 1973 as a temporary standard on measuring dry coating thickness. It became the rule for how many readings to take on a structure and how to judge them. In its 2012 edition, which took a committee five years, a spot measurement is the average of at least three readings within a 4 cm circle, an area measurement is the average of five spots in each 10 m², and a job of more than 1,000 square feet gets three areas in the first 1,000 and one more for each further 1,000.
LessonSome operators subtracted a fixed "correction value" from readings made with magnetic pull-off gauges, but those gauges are not linear, so the error changes with thickness, and PA 2 now says the practice is not appropriate.
Credit
SSPC Committee on Dry Film Thickness Measurement; account by KTA-Tator
1986
Certified coating inspectors
Norwegian industry set up FROSIO in 1986 to train and certify inspectors of surface treatment and corrosion protection, at three levels set by documented experience. It has been accredited since 2003 under ISO 17024, the standard for bodies that certify people, and says a FROSIO certificate is a specific requirement in several standards and specifications. In North America, NACE International's Coating Inspector Program and SSPC's Protective Coatings Inspector program did the same work; AMPP, the association that now runs both, says its new Coatings Inspector Program draws on "over 30 years" of the two and will eventually replace them in standards.
Credit
FROSIO; NACE International; SSPC; AMPP
1988
Inspectors on the strait bridges
Japan's Honshu–Shikoku Bridge Authority built long bridges over the straits between the islands of Honshu and Shikoku, and finished the Kojima–Sakaide route on 10 April 1988. With about 6,000,000 m² of steel to be coated on its three routes, it developed coatings to resist sea mist with long repainting cycles, wrote an inspection specification, and assigned full-time inspectors to check rust and corrosion daily or at set intervals, so that coatings are repaired before corrosion does harm. Walkways and inspection vehicles were built into the bridges.
Credit
Honshu–Shikoku Bridge Authority, in a 1989 paper by Katsushi Iwaya, Shigeshi Yoshida and Toshiya Nakao
1998
Paint that could block pumps
On 14 July 1998 the US Nuclear Regulatory Commission (NRC) wrote to every operating nuclear power plant about the coatings inside its containment building. Its Generic Letter 98-04 says coatings not qualified for accident conditions are assumed to come off during a loss-of-coolant accident and may be carried to the screens or strainers of the emergency sumps, where chips can cut the suction available to the pumps of the emergency core cooling and containment spray systems; it adds that some qualified coatings had failed in normal operation. Each plant had 120 days to describe how its safety-related coatings are bought, qualified, applied, inspected and maintained.
LessonInside a reactor building, peeling paint is a safety problem, so the coating program has to meet the plant's quality assurance rules.
Credit
US NRC
Watch for
Thickness read without contact
The common electronic dry film thickness gauges must touch the coat, which limits readings to where a person, or a drone that can push against a surface, can reach. Carolyn Ortiz, Kyle Crary, Rebekah Wilson and Brian Eick of the US Army Engineer Research and Development Center tested a photothermal method, which uses heat instead of contact, as a gauge that could be mounted on robotic vehicles, and compared it in the laboratory with a trusted contact method. They report both what it can do and its limits, and the difficulty of using it on complex, multi-coat systems.
Achieved whena noncontact gauge carried by a robot reads multi-coat systems on a working structure within the tolerance of a contact gauge, as checked by an outside inspector.
Claimed by
US Army Engineer Research and Development Center, report dated 24 July 2026
Open
01
Inspectors scored on panels
A public set of ten steel test panels, coated by brush or by drawdown bar, a blade drawn over the panel to leave a set thickness, with marked thin, thick and pinholed zones and a total thickness under 0.5 mm, measured in turn by at least 20 certified inspectors with their own gauges under SSPC-PA 2 and tested for pinholes with a low-voltage wet sponge. The panels' true thickness is found afterwards by cutting small cross-sections.
The briefCredit · unclaimed02
Same readings, different rules
A public, anonymized collection of the reading files that electronic gauges export, from real coating jobs and shared with the owners' permission, and an open script that runs each job through SSPC-PA 2's spot-and-area rule and the International Maritime Organization's 90/10 rule, reporting how often the two verdicts differ and how many readings each needed.
The briefCredit · unclaimed
Open 01 · the brief
Inspectors scored on panels
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public set of ten steel test panels, coated by brush or by drawdown bar, a blade drawn over the panel to leave a set thickness, with marked thin, thick and pinholed zones and a total thickness under 0.5 mm, measured in turn by at least 20 certified inspectors with their own gauges under SSPC-PA 2 and tested for pinholes with a low-voltage wet sponge. The panels' true thickness is found afterwards by cutting small cross-sections.
Why it is still open
KTA-Tator writes that PA 2's rules on how many readings to take cause "either under- or over-inspection," and that some operators corrected readings in ways the standard now rejects. The nearest work found is a National Shipbuilding Research Program study, revised in 2019, in which trained inspectors from four shipyards and a gauge maker measured six laboratory panels with four gauge methods; it reports each method's spread and time, not how far inspectors differ from one another or whether any passed a panel that fails. A November 2026 search also found a 2010 conference paper on the reproducibility of inspection data, behind a paywall, and a round robin on wood coatings, but no public panel set.
Built with what exists
steel test panels coated by brush or drawdown bar, never sprayed, by a coatings laboratory or a painters' training center; certified coated thickness standards to check each gauge; the inspectors' own magnetic gauges; a low-voltage wet-sponge holiday detector, which ASTM D5162 assigns to coatings up to 0.5 mm, leaving out high-voltage spark testers; a cutting gauge or a microscope for the cross-sections; a spreadsheet.
First step
Ask a coatings laboratory or a painters' training center to coat ten panels by brush or drawdown bar with marked thin and thick zones, and cross-section two of them to check the zones.
Done looks like
All readings from 20 inspectors on ten panels published, with the spread of area measurements on each panel, and the number of inspectors who passed a panel whose true thickness fails the specification, or failed one that meets it.
Open 02 · the brief
Same readings, different rules
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public, anonymized collection of the reading files that electronic gauges export, from real coating jobs and shared with the owners' permission, and an open script that runs each job through SSPC-PA 2's spot-and-area rule and the International Maritime Organization's 90/10 rule, reporting how often the two verdicts differ and how many readings each needed.
Why it is still open
The rules count differently. PA 2 averages at least three readings in a spot and five spots in each 10 m² area, while IMO's ballast-tank standard requires 90% of all readings to be at or above the nominal thickness and none of the other 10% below 90% of it. A November 2026 Crossref search found conference papers on meeting thickness specifications (SSPC 2015) and on the statistics of rapid thickness measurement (SSPC 2018), both behind paywalls, and no public file of readings from real jobs.
Built with what exists
gauge export files in CSV; Python; a language model to convert the different file layouts into one table; Zenodo to publish. ISO 19840, the international rule for coatings on rough steel, can be added once its text is bought.
First step
Write the script for both rules and test it on readings taken on one certified coated thickness standard and on a made-up job file.
Done looks like
At least 100 jobs from at least five contributors, released under an open license with the script, and a table giving the share of areas where the rules disagree.