BRENNEN

Industries / Technology / Telecommunications / Networking equipment

Plug-in optics

This work makes the swappable optical modules that plug into the ports of routers and switches, and writes the shared agreements that let one maker's module fit another maker's port.

5

Milestones achieved, from 1995 to 2020.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1995

    A swappable port module

    The GBIC (gigabit interface converter) is a small module that slides into a port on a switch or storage system and turns the port's electrical signal into light, or into a signal for copper cable. Its specification, SFF-8053, was first published in preliminary form on 29 November 1995 and revised until September 2000. It defines copper and optical modules for the same port, including long-wave single-mode fiber versions, and lays out how a module starts up when it is pushed in with the power on, which the specification calls hot plugging.

    members.snia.org

    Credit

    Vixel, Compaq and AMP, named as primary contributors in the specification

  2. 2001

    A smaller module, same controls

    The SFP (small form-factor pluggable) module does the GBIC's job in a smaller package. Its specification, INF-8074i, is dated 12 May 2001 and was written by a multi-source agreement (MSA), a pact among competing makers to build parts to one design. Fifteen companies took part, among them Agilent, Finisar, IBM, Infineon, Lucent, Molex and Tyco Electronics. The SFF Committee, the industry group that handled the GBIC, distributed the SFP document but says it did not develop or endorse it.

    Lessonthe last GBIC revision widened its scope to "non-GBIC devices with GBIC compatible controls such as SFP" and added the identity fields SFP needed, so equipment could manage both the same way.

    members.snia.orgmembers.snia.org

    Credit

    the SFP MSA group

  3. 2016

    Two shapes for 400G

    A lane is one electrical path between the switch chip and the module, and 400 Gbit/s modules needed eight lanes where the popular QSFP module had four. On 21 March 2016, 13 companies formed the QSFP-DD MSA to double QSFP's lanes in a port that still takes older QSFP modules; the group calls backward compatibility "critically important." On 15 November 2016, 49 companies led by Arista Networks formed a rival, the OSFP MSA, whose module puts heat handling first and fits 32 ports of 400G in one rack unit (1U, 44.45 mm of height); it takes QSFP modules only through an adapter. Both groups released specifications in March 2017 and both still revise them: QSFP-DD added a 1.6 Tbit/s version in September 2023, and OSFP posted revision 5.22 in August 2025.

    Lessonbackward compatibility and room for heat pulled in different directions, and the industry kept both shapes.

    qsfp-dd.comqsfp-dd.comosfpmsa.orgosfpmsa.orgosfpmsa.org

    Credit

    the QSFP-DD and OSFP MSA groups; Arista Networks

  4. 2017

    Optics sized to the building

    In March 2017 Facebook described CWDM4-OCP, a specification for 100 Gbit/s single-mode modules that it gave to the Open Compute Project. It started from the CWDM4 MSA, agreed by several suppliers in 2014, and dropped what a data center does not use: links shorter than 500 m, a case temperature range narrowed from 0–70 °C to 15–55 °C because its switch inlet air is controlled, and a shorter expected life than telecom parts, which can be rated for more than 20 years. Facebook's cost model found that the fiber and patch panels saved by using single-mode more than paid for the dearer modules. Japan's INTERNET Watch reported in December 2021 that CWDM4-OCP-100G had begun to circulate widely as a low-cost 100G standard.

    Lessona buyer that writes its own specification can cut cost by dropping requirements its buildings never test.

    engineering.fb.cominternet.watch.impress.co.jp

    Credit

    Facebook (now Meta)

  5. 2020

    Long-reach optics in the port

    On 29 April 2020 OIF, the industry body that writes optical interoperability agreements, published its 400ZR implementation agreement. It specifies a coherent module, one that reads the phase of light as well as its brightness, carrying 400 Gigabit Ethernet over amplified DWDM links of 120 km or less (dense wavelength-division multiplexing, where many colours of light share one fiber), small enough to plug straight into a switch or router port. Large data center operators asked for it, and OIF calls it its first project scoped to interoperability at one distance. Cignal AI, a market research firm, reported in March 2022 that 400ZR/ZR+ shipments surged in late 2021, led by Cisco (Acacia) and Marvell, and expected them to triple in 2022 as Microsoft, Amazon and Google were joined by AT&T, Windstream and Colt.

    Lessonaiming at one interoperable distance, not the best possible performance, let buyers mix modules from different makers on one link.

    oiforum.comcignal.ai

    Credit

    OIF and its members; Cisco (Acacia) and Marvell as the first volume suppliers, per Cignal AI

Watch for

  1. Optics without a DSP

    Linear pluggable optics (LPO) leave out the digital signal processor (DSP), the chip inside most fast modules that cleans up the signal, and rely on the switch chip to do that work. The LPO MSA, formed on 21 March 2024 by 12 companies including AMD, Arista, Broadcom, Cisco, Intel and NVIDIA, published its first specification on 25 March 2025. Axiom, a seller of optics, reported in February 2026 that in its own lab an 800G OSFP 2×DR4 LPO module drew about 8.0 W on average against about 16.0 W for a DSP-based one. In October 2026 Meta engineers Amin Yekani and Qing Wang gave a talk at the OCP Global Summit on "whether linear optics can match retimed reliability at fleet scale" (a retimed module is one with a DSP).

    Achieved whenan operator or an independent lab publishes measured power and failure counts for LPO links in service, including links that mix LPO and DSP-based modules.

    lpo-msa.orglpo-msa.orgaxiomupgrades.comengineering.fb.com

    Claimed by

    the LPO MSA's members; Axiom, February 2026; Meta, October 2026

Open

  1. 01

    Watts per module, measured

    A public table of the power that plug-in optical modules actually draw, measured the same way across many makers and types: SFP+, SFP28 and QSFP28 modules at 10 to 100 Gbit/s, and 400G and 800G modules, both LPO and DSP-based where a tested switch supports them, each idle and at full traffic, at two or more inlet air temperatures.

    The brief
    Credit · unclaimed
  2. 02

    An open optics acceptance log

    A public table of which plug-in modules each switch model accepts, by software version: whether the port comes up, comes up with a warning, or stays dark. For each case it saves the module's identity data, the contents of the small memory chip (EEPROM) where a module names its maker and part number.

    The brief
    Credit · unclaimed

Open 01 · the brief

Watts per module, measured

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of the power that plug-in optical modules actually draw, measured the same way across many makers and types: SFP+, SFP28 and QSFP28 modules at 10 to 100 Gbit/s, and 400G and 800G modules, both LPO and DSP-based where a tested switch supports them, each idle and at full traffic, at two or more inlet air temperatures.

Why it is still open

The measured figures published so far come from sellers testing their own products. Axiom, which sells optics, reports about 8.0 W for an 800G OSFP 2×DR4 LPO module against about 16.0 W for a DSP-based one from its own lab; Flexoptix, another seller, presented power for its own modules, read from the modules' internal metrics, at SwiNOG in April 2026. Web, GitHub and arXiv searches on 20 November 2026 found no independent table covering many makers.

axiomupgrades.comswinog.ch

Built with what exists

Second-hand switches whose software reports power, such as the Cisco Nexus 93600CD-GX, Cisco Catalyst 9500 and Juniper QFX5120 that Flexoptix used; a plug-in power meter on each switch's supply cord to check the switch's own figures; the modules' diagnostic readings (CMIS VDM pages) read through the switch command line; Class 1 (eye-safe) modules looped back with patch cords, never a live network; Zenodo for a citable release.

  1. First step

    Measure one switch's input power with all ports empty, then add 8 identical modules one at a time, to find the smallest per-module difference the setup can detect.

  2. Done looks like

    At least 60 modules from at least 8 makers, each measured by one written procedure (switch input power with the port empty, with the module idle, and with line-rate traffic, at two inlet temperatures), each value given with its spread over 10 repeats, with the raw logs published.

Open 02 · the brief

An open optics acceptance log

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of which plug-in modules each switch model accepts, by software version: whether the port comes up, comes up with a warning, or stays dark. For each case it saves the module's identity data, the contents of the small memory chip (EEPROM) where a module names its maker and part number.

Why it is still open

Switches read a module's identity and can refuse to bring a port up, and third-party makers program modules to identify as a named vendor's part. DataCenterDisk, a site that tracks module prices, says the compatibility lists on listings are seller claims that it records "rather than verify." GitHub searches on 20 November 2026 found tools that decode module memory (robinchrist/TransceiverTool) and one that exports a single vendor's internal compatibility database (Fortinet's), but no open table across switch makers.

datacenterdisk.com

Built with what exists

Second-hand switches from several makers (for example Cisco, Arista, Juniper, HPE Aruba and MikroTik); new and used SFP+, SFP28 and QSFP28 modules, Class 1 only; Linux ethtool -m and TransceiverTool to read and decode the identity data; a shared CSV layout.

  1. First step

    Test 5 modules from different makers in 2 switches, publish the dumps and results, and invite owners of other switches to add rows.

  2. Done looks like

    At least 15 switch models and 40 modules, every pairing recorded with the software version and the port state after 10 minutes, the raw memory dumps published, and a second person repeating 10% of the pairings with the same result.