BRENNEN

Industries / Industrial equipment and services / HVAC equipment

Coils and heat exchangers

Coils and heat exchangers are the finned tubes and stacked plates where the refrigerant takes heat from indoor air or water and gives it up outside, and making them means forming tubes and fins, joining them by brazing and testing them for leaks.

4

Milestones achieved, from 1923 to 2006.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1923

    Finned coils replace cast iron

    In May 1923 Willis Carrier and three large fan makers founded the Aerofin Corporation to make coils of thin brass and copper fins on tubes, which by Carrier's account offered "a lightweight, brass and copper alternative to bulky cast-iron heat exchangers". Fins add surface for air to touch, so a small coil moves as much heat as a much heavier block. Round tubes through thin plate fins, usually copper tubes and aluminum fins, remained the standard coil in commercial equipment into the 2000s, ACHR News wrote in 2008.

    williscarrier.comachrnews.com

    Credit

    Willis Carrier and partner fan manufacturers, Aerofin Corporation

  2. 1988

    Flat tubes for car condensers

    On 7 January 1988 Modine Manufacturing filed a US patent for a condenser built from flattened aluminum tubes, each holding several tiny parallel channels between two headers; it was granted in 1991. Such microchannel coils, brazed together in one pass through a furnace, were taken up in cars when the ozone treaty forced a switch from the refrigerant R-12 to R-134a, which, by the account below, cut the capacity of older copper-and-aluminum condensers by about 20%. A 2002 ACHR News article by a maker of microchannel tubing said that more than 75% of vehicles by then used these parallel-flow condensers.

    patents.google.comachrnews.com

    Credit

    Leon A. Guntly and Norman F. Costello, Modine Manufacturing

  3. 2005

    Ants'-nest corrosion explained

    Copper coil tubes in air conditioners were failing from pinholes too small to see, made by branching tunnels called formicary, or ants'-nest, corrosion. A report for the Air-Conditioning and Refrigeration Technology Institute (ARTI) by Richard Corbett and Dave Severance reviewed more than 60 studies, mostly Japanese, and built a laboratory screening test. It found that organic acids such as formic and acetic acid, formed when lubricants, cleaners and other chemicals break down, cause the attack, that vapors matter most, and that formic acid attacked copper below 20 parts per million. ACHR News reported in 2007 that the leaks hit all brands and that Trane was moving its coils from copper to aluminum, which this corrosion does not attack.

    LessonTrace chemicals in the air around a coil can perforate copper tubes within weeks or months, so a coil's surroundings matter as much as its metal.

    osti.govachrnews.com

    Credit

    Richard A. Corbett and Dave Severance (ARTI); Yamauchi and colleagues, who named the corrosion in 1983; Trane

  4. 2006

    Microchannel coils come home

    A Samsung engineer, G. Hayase, wrote that Samsung Electronics put microchannel condensers in the outdoor units of its cooling-only air conditioners from 2006. ACHR News reported in 2008 that US makers had moved microchannel coils into home equipment when the minimum efficiency rose to 13 SEER, because they cut unit size and refrigerant charge by up to 50%, and that York, Carrier and McQuay had just put them in chillers and rooftop units. Using them on the cold side was harder: Samsung needed until 2011 for an indoor evaporator, and until 2012 and 2013 for heat pump versions, changing to flat fins to deal with frost and defrosting. The 2002 article had already named draining condensed water as a problem still to solve.

    LessonA coil that works well as a condenser needs redesign as an evaporator, where condensed water and frost collect on it.

    iifiir.orgachrnews.comachrnews.com

    Credit

    Samsung Electronics; Johnson Controls (York), Carrier and McQuay

Watch for

  1. Robot brazes and grades joints

    Researchers report a system in which a collaborative robot, a robot arm built to work beside people, brazes copper tubes, a camera running an object-detection model guides it to each joint, and a second model watching ordinary and thermal video grades every braze. They report an F1 score, a measure that balances missed defects against false alarms, of 98% "under target manufacturing conditions".

    Achieved whena coil or equipment maker, or another lab, runs the method on a production line and publishes its grades checked against leak tests.

    sensors.myu-group.co.jp

    Claimed by

    Eugene Kim, Hwanhee Kang, Myeongjin Kim, Hyunrok Cha and Younggon Kim, in Sensors and Materials, April 2026

Open

  1. 01

    Brazed joints graded against leaks

    An open set of photos and short thermal videos of torch-brazed copper joints like those on coil return bends and headers, each joint leak-tested and a sample cut in half to measure how far the filler metal flowed, plus a baseline model that predicts from the photo whether a joint will leak or is poorly filled.

    The brief
    Credit · unclaimed
  2. 02

    Household vapors versus copper coils

    A public table that ranks common indoor products, such as cleaners, air fresheners, paints, adhesives, sealants and new cabinetry, by how much ants'-nest corrosion their vapors cause on copper coil tubing, using the ARTI screening method, with microscope photos and cross-sections for each.

    The brief
    Credit · unclaimed

Open 01 · the brief

Brazed joints graded against leaks

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open set of photos and short thermal videos of torch-brazed copper joints like those on coil return bends and headers, each joint leak-tested and a sample cut in half to measure how far the filler metal flowed, plus a baseline model that predicts from the photo whether a joint will leak or is poorly filled.

Why it is still open

A 2015 report for the US Department of Energy says factory and field technicians inspect brazed joints "primarily through a visual examination", then may pressure-test the system, and that x-ray and ultrasonic checks are impractical or costly for everyday use; it notes leaks still occur because equipment holds so many joints. Machine-brazed joints have been graded by camera: Lee and colleagues (2024) brazed 12.7 mm copper tube by induction heating, judged each joint by cutting it open to measure how far the filler ran, and trained a model on thermal images that scored an F1 of 0.991; the article page gives no data statement. The 2026 robot study above graded its own process and its page does not offer the data. Searches in November 2026 found no public image set of hand-brazed copper joints with leak-test or cross-section results.

osti.govlink.springer.comsensors.myu-group.co.jp

Built with what exists

A phone camera on a fixed holder with a ring light and a low-cost phone thermal camera; Label Studio for labels; an Ultralytics YOLO11 detector; a model that returns a probability for each answer on a fixed scale, such as Gemini Decision 1, for the pass, rework or fail grade (see the Note "A thousand questions, one pass"); a tracer-gas leak test using 5% hydrogen in nitrogen, which is not flammable, and an electronic hydrogen leak detector; a metallographic cut-off saw. No refrigerant is used.

  1. First step

    Ask an HVAC trade school to photograph 50 student practice joints before the instructor's pressure test and record each result.

  2. Done looks like

    1,000 joints from at least three trade schools or coil shops, each with photos, a leak result and an instructor's visual grade, and 200 of them sectioned; the model's share of leaking joints caught, at a fixed false-alarm rate, published next to the instructors' own, with photos and labels under an open license.

Open 02 · the brief

Household vapors versus copper coils

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table that ranks common indoor products, such as cleaners, air fresheners, paints, adhesives, sealants and new cabinetry, by how much ants'-nest corrosion their vapors cause on copper coil tubing, using the ARTI screening method, with microscope photos and cross-sections for each.

Why it is still open

ARTI's 2005 test was built to screen fluids used in making coils, for forming, joining and insulating them, and its exposures used formic and acetic acid solutions and ethylene glycol extracts. Later work looked at single cases or mechanisms: a 2022 AMPP conference paper by Steiner found formic acid in a building sealant that corroded copper medical-gas tubes, and Situmorang and Kawai (2018) studied the mechanism in copper formate solution. Crossref searches in November 2026 found no product-by-product table for the vapors found in homes.

osti.govapi.crossref.orgapi.crossref.org

Built with what exists

ARTI's published procedure and its 40/20 °C daily temperature cycle; sealed glass jars; a programmable incubator or two water baths; seamless copper tube of the UNS C12200 grade used in coils; a metallurgical microscope; a low-cost formaldehyde and volatile organic compound meter; a university lab for ion chromatography if acid levels are wanted.

  1. First step

    Start two jars, a 20 ppm formic acid control and a deionized-water blank, each holding cleaned tube pieces, on ARTI's temperature cycle.

  2. Done looks like

    At least 30 products tested in triplicate for 90 days, with the deepest pit for each, a formic acid control at 20 ppm that reproduces ARTI's threshold finding, and every photo and number published under an open license.