HVAC equipment manufacturing is designing, building and testing the machines that heat, cool, ventilate and refrigerate buildings, from compressors, coils and controls to whole air conditioners, heat pumps and chillers.

1902

Willis Carrier, an engineer at the Buffalo Forge Company, designed a system that controlled humidity with cooling coils for the Sackett-Wilhelms Lithographing and Publishing Company in Brooklyn, where damp air was wrinkling pages. The US Department of Energy calls it the first modern electrical air conditioning unit. His patent for an "apparatus for treating air" was filed in 1904 and granted on 2 January 1906.

energy.govpatents.google.com

38

Milestones achieved across 6 domains.

8

To watch for: announced, not yet confirmed outside.

12

Open deliverables. Nobody has shipped them.

In one minute

Where it started

Machines that make cold go back to Jacob Perkins's vapor-compression patent of 1834, and in 1902 Willis Carrier used cooling coils to control the air in a Brooklyn printing plant. Carrier's centrifugal chiller of 1922 cooled theaters and stores, General Electric's sealed Monitor Top refrigerator of 1927 brought the hermetic compressor into homes, and the CFC refrigerants that General Motors chemists introduced in 1930 made small machines safe to sell, until they were found to destroy ozone.

Where it stands

The International Energy Agency (IEA) counted about 1.6 billion air conditioners in use at the end of 2016, more than half of them in China and the US, using over 2,000 TWh of electricity a year, almost a fifth of all electricity used in buildings; 135 million were sold that year. Makers are changing refrigerants again: the 2016 Kigali Amendment schedules cuts in HFCs, new US home units moved to mildly flammable refrigerants in 2025, and EU bans that begin in 2027 rule out most F-gases in small new units within ten years. Heat pump sales fell 1% worldwide in 2024 by the IEA's count, as summarized by its heat pump program, and 22% in Europe by the European Heat Pump Association's.

What is open

Much of what decides how well this equipment works is measured only by its makers or in a few laboratories: how each compressor performs across its range, how thermostats and fault alarms behave, how installed units compare with their ratings, and how the new refrigerant leak sensors age. Cheap sensors and data loggers, open energy monitors and simulation tools, and AI models that read datasheets and reports now let a small team build the test benches, data sets and ledgers listed below and publish results that others can repeat.

Domains

AchievedWatch forOpen

Advances to build with

1 research note

Open in hvac equipment

3 of 12 open deliverables

Open · Compressors

Open drive for fridge compressors

Open-source motor-control firmware and a small circuit board that run a 12 or 24 V DC refrigerator compressor, such as Secop's BD35F, without the maker's electronic unit, plus a published comparison of energy use against the stock unit in the same fridge. These compressors cool portable and solar-powered fridges, where every watt counts. The work stays at low voltage and leaves the factory-sealed refrigerant circuit closed.

Built with what exists

VESC's open-source motor firmware or an STM32 motor-control kit; small gallium nitride (GaN) half-bridges such as ST's GANSPIN1102 (see the Note "A half-bridge in 6.5 by 5 mm"); a portable compressor fridge bought new; a 12 V bench supply, a DC power meter and temperature loggers; an AI coding agent to port and test the firmware.

Credit · unclaimed

Open · Coils and heat exchangers

Brazed joints graded against leaks

An open set of photos and short thermal videos of torch-brazed copper joints like those on coil return bends and headers, each joint leak-tested and a sample cut in half to measure how far the filler metal flowed, plus a baseline model that predicts from the photo whether a joint will leak or is poorly filled.

Built with what exists

A phone camera on a fixed holder with a ring light and a low-cost phone thermal camera; Label Studio for labels; an Ultralytics YOLO11 detector; a model that returns a probability for each answer on a fixed scale, such as Gemini Decision 1, for the pass, rework or fail grade (see the Note "A thousand questions, one pass"); a tracer-gas leak test using 5% hydrogen in nitrogen, which is not flammable, and an electronic hydrogen leak detector; a metallographic cut-off saw. No refrigerant is used.

Credit · unclaimed

Open · Refrigerants

A ledger of refrigerant fires

A public, sourced table of fires, explosions and injuries worldwide in which the refrigerant of an air conditioner, heat pump or refrigerator played a part. Each row gives the date, place, equipment, refrigerant and its safety class (A1 nonflammable, A2L mildly flammable, A3 flammable such as propane, or an illegal blend), the stage (installation, service, normal use, disposal), the cause as found, and how good the source is (official investigation, court record, recall notice, news report). Then, where sales data allow, a rate of incidents per million units in service for each class.

Built with what exists

Public recall and alert databases such as the US Consumer Product Safety Commission's recalls and the EU's Safety Gate; news archives and published fire investigation reports; a browser agent such as Browser Use (see the Note "Deleting 80% to start over") to search them slowly and within each site's rules; a low-cost extraction model such as Muse Ember (see the Note "The jobs agents repeat") to pull the fields from each report; SQLite or a spreadsheet; sales figures from EHPA and JRAIA for the rates.

Credit · unclaimed