Refrigerants are the working fluids that carry heat inside air conditioners, heat pumps and refrigerators; this work is choosing them, and redesigning equipment each time a rule retires the one in use.

7

Milestones achieved, from 1930 to 2026.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1930

    Freon replaces toxic refrigerants

    Early refrigerators ran on gases such as ammonia, sulfur dioxide and methyl chloride, which Invention & Technology magazine describes as "not only toxic but highly combustible." Charles Kettering, research chief of General Motors, set Thomas Midgley Jr. to find a safer refrigerant for GM's Frigidaire refrigerators. With Albert Henne and Robert McNary he chose dichlorodifluoromethane, a chlorofluorocarbon (CFC) later sold as Freon 12. They published "Organic Fluorides as Refrigerants" in Industrial & Engineering Chemistry in May 1930, and their patent, assigned to Frigidaire, was filed on 5 April 1930. At the American Chemical Society's 1930 meeting Midgley breathed in the vapor and blew out a candle with it, and GM and DuPont formed Kinetic Chemicals to sell it.

    LessonA refrigerant can be safe for the people beside it and still harm the atmosphere: in 1974 Mario Molina and F. S. Rowland showed in Nature that CFCs reaching the stratosphere release chlorine atoms that destroy ozone, and the Montreal Protocol of 1987 set CFCs on the way out.

    api.crossref.orgpatents.google.cominventionandtech.comapi.crossref.org

    Credit

    Thomas Midgley Jr., Albert L. Henne and Robert R. McNary; Frigidaire (General Motors); Kinetic Chemicals (GM and DuPont)

  2. 2012

    R-32 replaces R-410A

    Air conditioners had long used R-410A, a hydrofluorocarbon (HFC) blend that spares the ozone layer but traps heat strongly. In 2012 Daikin began selling a household air conditioner using a single HFC, R-32, whose global warming potential (GWP, how much heat a gas traps compared with the same mass of carbon dioxide) is about one third of R-410A's, by Daikin's figure. Daikin calls it the world's first. Daikin opened 93 patents on R-32 equipment free of charge to emerging countries in 2011 and to everyone in 2015, and in 2019 pledged not to enforce about 180 later ones, Cooling Post reported. By then Daikin sold R-32 units in more than 60 countries, and the US Environmental Protection Agency (EPA) lists R-32 as acceptable, with conditions, in home air conditioners and heat pumps.

    kyodonewsprwire.jpcoolingpost.comfederalregister.gov

    Credit

    Daikin Industries

  3. 2016

    A deadline for HFCs

    The Kigali Amendment to the Montreal Protocol, agreed at a meeting of its parties in Kigali on 10–15 October 2016, put HFCs on a schedule. Each country's HFC production and use is measured in tonnes of CO2 equivalent against a baseline, and must fall in steps. For most developed countries it falls to 15% of the 2011–2013 level (plus part of their older HCFC use) from 2036. Most developing countries freeze in 2024 at their 2020–2022 level and cut to 20% of it from 2045. The amendment entered into force on 1 January 2019, and it allows an exemption for countries with very hot climates.

    ozone.unep.org

    Credit

    the Parties to the Montreal Protocol, with the UN Environment Programme's Ozone Secretariat

  4. 2022

    More propane allowed indoors

    Propane (R-290) is a hydrocarbon refrigerant that burns easily, so safety standards cap how much of it equipment may hold for a given room. After more than six years of revision, the International Electrotechnical Commission (IEC) approved a new edition of IEC 60335-2-40, its safety standard for electric air conditioners and heat pumps, on 29 April 2022, with publication set for 24 June 2022. It lets a new split air conditioner hold up to 988 g of propane instead of 334 g, if the unit is built tighter and uses more airflow, leak detectors and safety shut-off valves. It also covers mildly flammable refrigerants such as R-32. Each country must still adopt it, the International Institute of Refrigeration noted.

    iifiir.org

    Credit

    International Electrotechnical Commission

  5. 2024

    Europe sets refrigerant ban dates

    Regulation (EU) 2024/573, signed on 7 February 2024, bans fluorinated greenhouse gases (F-gases, which include HFCs) from most small air conditioners and heat pumps sold in the EU, by date. Self-contained units up to 12 kW, built as one sealed box (monoblocs), may not use F-gases with a GWP of 150 or more from 1 January 2027, and may not use F-gases at all from 2032. Split systems up to 12 kW, with an indoor and an outdoor unit joined by refrigerant pipes, lose F-gases with a GWP of 150 or more from 2027 if they heat water and from 2029 if they heat or cool air, and lose all F-gases from 2035. Each ban has an exception where safety requirements at the site rule out the alternative. The EU's supply of HFCs falls to zero from 2050, and the European Commission must check each year whether the cuts are starving the heat pump market.

    eur-lex.europa.eu

    Credit

    European Parliament and Council of the EU

  6. 2025

    The US switches refrigerant

    Under the American Innovation and Manufacturing (AIM) Act of December 2020, an EPA rule of 24 October 2023 barred HFCs with a GWP of 700 or more from new home and light commercial air conditioners and heat pumps. Self-contained products could no longer be made or imported with them from 1 January 2025, and systems assembled on site could no longer be installed with them from that date; variable refrigerant flow (VRF) systems had until 2026. Makers moved from R-410A to R-454B and R-32, which are in the A2L safety group (mildly flammable). HARDI, a distributors' association, reported that A2L equipment reached 90% of the market by November 2025, as cited by EPA. In 2025 R-454B was made in sufficient quantity but was scarce in some regions in the service cylinders that contractors use to charge new systems. In May 2026 EPA let R-410A equipment made or imported before 2025 be installed with no deadline.

    LessonA refrigerant change can stall on packaging: EPA found the new gas existed, but the cylinders installers needed did not reach every region.

    federalregister.govfederalregister.gov

    Credit

    US Congress; US Environmental Protection Agency

  7. 2026

    Fake refrigerant starts fires

    South Korea's National Fire Agency has blamed a run of air conditioner fires on illegal mixed refrigerants containing R-40 (methyl chloride), Cooling Post reported in September 2026. The agency recorded 36 suspected refrigerant-related fires in five years. In each, the outdoor unit held trimethyl aluminum, a liquid that catches fire on contact with air and forms when R-40 reacts with the aluminum inside the equipment. Such fires rose from 1 in 2022 to 13 in 2025, with 14 by July 2026. In December 2025 Canada found R-40 in cylinders labeled R-32.

    LessonA unit is only as safe as the refrigerant put into it during service, and the aluminum inside air conditioners reacts with R-40 to form a substance that ignites in air.

    coolingpost.com

    Credit

    a failure; investigation by Korea's National Fire Agency

Watch for

  1. PFAS rules may reach refrigerants

    The EU is weighing a restriction on PFAS, the "forever chemicals", as one group, which would take in many fluorinated refrigerant gases. In 2026 the Risk Assessment Committee of the European Chemicals Agency (ECHA) concluded that PFAS pose a risk and backed an EU-wide group restriction. It estimated F-gas emissions at about 40,000 tonnes a year, mostly from stationary air conditioning and heat pumps, commercial refrigeration and foam blowing. The draft opinion of ECHA's Socio-Economic Analysis Committee found the restriction workable with some time-limited exemptions, and its final opinion is expected by the end of 2026.

    Achieved whenthe European Commission adopts a restriction that names refrigerant uses and dates.

    eia-international.org

    Claimed by

    ECHA's Risk Assessment and Socio-Economic Analysis Committees, as reported by the Environmental Investigation Agency, March 2026

  2. More US refrigerant choices

    EPA proposed to accept three more refrigerants, with conditions, in new home and light commercial air conditioners and heat pumps: R-516A, HCR 4141 and HFO-1234ze(E). It also proposed new conditions for refrigerants already listed, including R-32, R-454B and propane. Propane stays listed only for self-contained room air conditioners, not for split or ducted systems.

    Achieved whenEPA publishes a final rule.

    federalregister.gov

    Claimed by

    US EPA, November 2025

Open

  1. 01

    A ledger of refrigerant fires

    A public, sourced table of fires, explosions and injuries worldwide in which the refrigerant of an air conditioner, heat pump or refrigerator played a part. Each row gives the date, place, equipment, refrigerant and its safety class (A1 nonflammable, A2L mildly flammable, A3 flammable such as propane, or an illegal blend), the stage (installation, service, normal use, disposal), the cause as found, and how good the source is (official investigation, court record, recall notice, news report). Then, where sales data allow, a rate of incidents per million units in service for each class.

    The brief
    Credit · unclaimed
  2. 02

    Bench-age A2L leak sensors

    A year-long bench test of the refrigerant leak sensors now built into many US home air conditioners and heat pumps that use mildly flammable (A2L) refrigerants such as R-454B and R-32. Buy replacement sensors of several makes, power them as the equipment does, and keep them in warm, humid air while exposing them in turn to vapors common in homes, such as curing spray foam, cleaning sprays, cooking fumes and silicone sealant. Once a month, check each sensor's reading and response time with a certified calibration gas that holds the refrigerant far below the level at which it can burn, and log every false alarm in between. No refrigerant circuit is opened.

    The brief
    Credit · unclaimed

Open 01 · the brief

A ledger of refrigerant fires

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public, sourced table of fires, explosions and injuries worldwide in which the refrigerant of an air conditioner, heat pump or refrigerator played a part. Each row gives the date, place, equipment, refrigerant and its safety class (A1 nonflammable, A2L mildly flammable, A3 flammable such as propane, or an illegal blend), the stage (installation, service, normal use, disposal), the cause as found, and how good the source is (official investigation, court record, recall notice, news report). Then, where sales data allow, a rate of incidents per million units in service for each class.

Why it is still open

An unsigned annex hosted by the ToxicDocs archive, written against hydrocarbon refrigerants, says "there is no systematic monitoring" of accidents with them and that fire brigades and insurers do not record them; it lists a dozen selected news reports. From the other side, the European FluoroCarbons Technical Committee (EFCTC), a group of fluorocarbon makers, published in December 2013 a count of refrigerant accidents found by a Google search of 2006–2013 news across ammonia, hydrocarbons, CO2 and fluorocarbons; it says the count "does not claim to be comprehensive" and that the press may not report accidents with fluorocarbons, which rarely explode. Korea's fire agency counted one kind of fire in one country. Searches in November 2026 found no current, sourced table across refrigerant types compiled by a party with no product to sell.

cdn.toxicdocs.orgfluorocarbons.orgcoolingpost.com

Built with what exists

Public recall and alert databases such as the US Consumer Product Safety Commission's recalls and the EU's Safety Gate; news archives and published fire investigation reports; a browser agent such as Browser Use (see the Note "Deleting 80% to start over") to search them slowly and within each site's rules; a low-cost extraction model such as Muse Ember (see the Note "The jobs agents repeat") to pull the fields from each report; SQLite or a spreadsheet; sales figures from EHPA and JRAIA for the rates.

  1. First step

    Pull every EU Safety Gate alert since 2015 for air conditioners, heat pumps, dehumidifiers and refrigerators that mentions the refrigerant, and code the first 50.

  2. Done looks like

    At least 300 incidents from at least 15 countries since 2010, each linked to its source and graded for source quality; two people independently code a random 50, and their agreement is published; a table of incidents by refrigerant class and stage, released under an open license.

Open 02 · the brief

Bench-age A2L leak sensors

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A year-long bench test of the refrigerant leak sensors now built into many US home air conditioners and heat pumps that use mildly flammable (A2L) refrigerants such as R-454B and R-32. Buy replacement sensors of several makes, power them as the equipment does, and keep them in warm, humid air while exposing them in turn to vapors common in homes, such as curing spray foam, cleaning sprays, cooking fumes and silicone sealant. Once a month, check each sensor's reading and response time with a certified calibration gas that holds the refrigerant far below the level at which it can burn, and log every false alarm in between. No refrigerant circuit is opened.

Why it is still open

The US safety standard UL 60335-2-40 sets a 10-second response time and a list of contaminants for these sensors. In lab tests at the University of Maryland, working with Carrier, every sensor type but one, a non-dispersive infrared (NDIR) sensor, changed its output after exposure to that list, and the 2022 thesis says "long term exposure, exposure to contaminants and refrigerant at the same time, and service lifetime are still concerns". A 2024 Department of Energy review slide lists an AHRTI study that developed a test method and evaluated six sensors of four sensing types with R-32; AHRTI is the research institute of AHRI, the makers' trade association. MRCOOL, a seller of do-it-yourself mini splits, wrote in September 2025 that off-gassing from spray foam used to seal wall holes can set off the sensors in new R-454B units; it gave no counts. Searches in November 2026 found no published long-term aging results for the sensors sold in equipment, and no independent count of false alarms.

drum.lib.umd.edudocs.lib.purdue.eduenergy.govmrcooldiydirect.com

Built with what exists

Replacement leak sensors sold as service parts by equipment makers, and sensors from component makers such as TE Connectivity; a sealed acrylic test box with a small fan, inside a ventilated room; certified calibration gas mixtures of R-32 and R-454B in air from a specialty gas supplier; saturated salt solutions or a humidifier to hold humidity; a microcontroller to log each sensor's output and alarm line; Python.

  1. First step

    Buy two replacement sensors of one model, log their output for a week, then expose them for a day to a freshly foamed scrap board in the box and record any alarms.

  2. Done looks like

    At least six sensor models, three units of each, run for 12 months; for each model a published table of monthly readings at the calibration level, drift from the first reading, response times against the 10-second requirement, and false alarms under each vapor; the box design and code released so another lab can repeat it.