Industries / Construction and property / Commercial and residential construction / Glazing
Fabrication
Fabrication is the shop and factory work: sealing panes of glass into insulating units, and cutting and joining the aluminum, vinyl or wood frames that hold them.
7
Milestones achieved, from 1865 to 2022.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1865
Two panes sealed together
Thomas D. Stetson's US patent 49,167, "Improvement in window-glass", dated 1 August 1865, joins two sheets of glass around their edges with putty laid over a stick or string that holds them apart. He told makers to put the sheets together warm and in dry air, to enclose as little moisture as possible, then to press them under weight; "after a few weeks the panes are ready for transportation or use". The Villum Window Collection says such units were not made until the 1930s.
LessonThe sealed double pane was easy to describe and hard to make; Stetson's putty edge took weeks to set, and factory production waited some 70 years.
Credit
Thomas D. Stetson
1905
Metal bars hold shop glass
Francis J. Plym filed a US patent on 8 July 1905, granted 15 May 1906, for a sash bar for all-glass shop fronts: a pressed-metal face piece with a back piece of springy metal that would "engage the glass with a firm but yielding pressure", keeping the fit tight as glass and metal expand and contract. His later patents were assigned to the Kawneer Manufacturing Company, which dates its founding to 1906 and still sells storefront, window-wall and curtain-wall framing.
Credit
Francis J. Plym; Kawneer
1934
Double glazing sealed in factories
Charles D. Haven filed a patent on 12 October 1934, granted in 1936 to the Thermopane Company, for a glazing unit of several sheets meant to be "moisture and frost resisting" and to last as long as a single sheet: the gap between the sheets is flushed with dried air for about three hours in a heated cabinet, then sealed. His later patents on the units and the machines that make them were assigned to the Libbey-Owens-Ford Glass Company, which sold the units as Thermopane. Marc Ó Riain, in a Passive House Plus column on the history of low-energy building, says its promotion made double glazing "very successful through the 1950s and 60s in the US"; Andersen's Flexivent window with welded insulating glass doubled the company's market share within two years in the 1950s, by the International Directory of Company Histories' account.
patents.google.commail.passivehouseplus.co.ukencyclopedia.com
Credit
Charles D. Haven; Libbey-Owens-Ford
1954
Frames made from PVC
The first PVC (vinyl) windows made in series came off a line in Troisdorf, near Bonn, Germany, in 1954 under the brand TROCAL, according to profine, the company that now owns the brand. Those first frame profiles had a single hollow chamber; in the 1970s profiles were divided into several chambers to insulate better. In 2004 PVCplus, a German PVC industry group, said PVC windows held about 55% of the German market and more than 80% of the British.
Credit
TROCAL, Troisdorf
1994
Spacers laid by machine
An insulating glass unit's panes are held apart at the edge by a spacer, usually a bar that has to be sawn, bent, joined, filled with desiccant (a drying agent) and coated with butyl sealant, each a separate step. LiSEC of Austria began making insulating glass systematically in 1966, and by 1978 machines for making it automatically were most of its business. In 1994 Karl Lenhardt began work on applying a thermoplastic spacer (TPS) straight onto the glass from a nozzle, which removes the sawing, bending and filling steps and lets one line make units of any size with two operators. Glaston, which now sells the process, counts more than 160 TPS lines and over 100 million units made on them.
Credit
Peter Lisec; Karl Lenhardt
1996
Vacuum glazing goes on sale
Vacuum glazing seals two panes around a gap of a fraction of a millimetre with the air pumped out, held open by tiny pillars. The idea was first described in a 1913 patent by A. Zoller, and Richard Collins's group at the University of Sydney made its first thermally insulating sample on 2 June 1989. Collins says many companies were approached from 1989 to 1993 without success, until Nippon Sheet Glass (NSG) signed a licence in late 1994 and launched Spacia in 1996; he reports several million units sold and U-values as low as 0.6 W/m²K in 10 mm thick units. NSG calls Spacia the world's first commercially available vacuum glazing and gives its vacuum layer as 0.2 mm.
LessonThe physics was settled long before the product; Collins counts 75 years from the idea to a working sample, and companies held back because some steps, such as placing the pillars, had no existing technology. 00025-2).
Credit
Richard Collins and the University of Sydney; Nippon Sheet Glass
2022
Triple glazing, double thickness
A conventional triple-glazed unit is heavier and about half an inch thicker than a double, so frames must be redesigned, and triple glazing made up less than 3% of US window sales. A "thin triple" puts a center pane about 1.6 mm thick, like a phone screen, between two ordinary panes, with krypton or argon gas, in a unit as thick as a double; NFRC-certified thin-triple windows were being made by Alpen HPP, Andersen and Ply Gem, with U-factors of 0.14 to 0.18 Btu/h·ft²·°F for fixed picture windows against 0.27 to 0.30 for double-pane low-e ones. In tests for the US Department of Energy at the Pacific Northwest National Laboratory's matched Lab Homes, they cut daily heating and cooling energy by an average of 12% in heating weather and 27% in cooling weather, and cost about $6 per square foot more than double panes with vinyl frames.
LessonA better unit spreads more easily when it fits the frames factories already make.
Credit
Pacific Northwest National Laboratory (Katherine Cort, Patricia Gunderson and colleagues); Lawrence Berkeley National Laboratory
Watch for
Vacuum glass at factory scale
LuxWall, a Michigan company, opened its first factory in Litchfield, Michigan, in summer 2024 and on 28 October 2025 showed a 276,000 sq ft factory in Detroit set to open in late 2026. It says its Enthermal vacuum glass lets windows and facades "insulate like walls"; it told Canary Media in December 2024 that its units had reached R-18 and insulate five times better than double-pane glass, against about R-2 to R-3 for double glazing.
Achieved whenNFRC-certified ratings or an outside laboratory's measurements of Enthermal units are published, along with durability results by the methods the National Renewable Energy Laboratory is drafting for vacuum glazing.
Claimed by
LuxWall, October 2025
Every unit checked for gas
Sparklike, a Finnish maker of gas-measuring devices, says Shengmu Technology Glass in China has installed Asia's first fully automated inline system that measures the argon in every insulating unit without breaking it, built with GFP of Germany, and that the line holds argon at 90% to 95% across the whole run; it adds that the units' sealed edge keeps the argon for 25 years.
Achieved whenan outside test laboratory measures a random sample of delivered Shengmu units, and the same units again after a year or an accelerated aging test, and finds the stated argon content.
Claimed by
Sparklike and Shengmu Technology Glass, November 2026
Open
01
Argon in new windows
A public survey of the argon in new double- and triple-pane units on sale in North America and Europe, measured without breaking them and compared with the fill their makers state, with every reading published by brand and date code, and a share of the units measured again after a year outdoors.
The briefCredit · unclaimed02
Vacuum glass after twenty years
A field survey of vacuum glazing installed 10 to 30 years ago, measuring each unit's heat flow on cold nights and checking for lost vacuum or cracked edges, to give a public record of how vacuum glazing lasts in buildings.
The briefCredit · unclaimed
Open 01 · the brief
Argon in new windows
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public survey of the argon in new double- and triple-pane units on sale in North America and Europe, measured without breaking them and compared with the fill their makers state, with every reading published by brand and date code, and a share of the units measured again after a year outdoors.
Why it is still open
The surveys found measure installed units or publish only summaries. In a 2025 conference paper, Chris Davis of H.B. Fuller and co-authors from Glasscheck, a Finnish testing firm, the British Fenestration Rating Council, NSG and others report Glasscheck's readings of 1,116 installed units made from 2000 to 2024, with a mean argon content of 59%, and readings in five London office buildings that ranged from 1% to 90%; the paper gives charts, not unit-by-unit data, and does not compare new units on sale with what their makers state. Sparklike reported in April 2026 that a 2022 study by the Beijing Building Materials Testing Academy tested 128 units from China's construction market and found the required gas content in 34% of them, and that units starting at 85% to 90% argon had fallen to 79% after six months. Sparklike also says most units are checked only by batch sampling. A November 2026 search found no survey of new units on sale outside China, and a 2025 arXiv paper offering a cheaper ultrasonic method (Khaleghi, Ozevin and Karatas) has been withdrawn.
Built with what exists
A handheld gas analyzer that reads through the glass, such as the Sparklike Laser Portable; windows and units on display or on sale at dealers and home centers, measured with permission; a spreadsheet of brand, date code, stated fill and measured fill.
First step
Borrow or rent a portable analyzer and measure 20 units on display at two window dealers.
Done looks like
At least 200 units from at least 10 brands, each read three times, published with brand and date code; the share below its stated fill and below 90%; and repeat readings of 50 units kept outdoors for 12 months.
Open 02 · the brief
Vacuum glass after twenty years
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A field survey of vacuum glazing installed 10 to 30 years ago, measuring each unit's heat flow on cold nights and checking for lost vacuum or cracked edges, to give a public record of how vacuum glazing lasts in buildings.
Why it is still open
The claim of durability rests on the makers' side. Collins says several million Spacia units have been sold since 1996 and that installed units "have shown excellent reliability", without field data in his 2017 talk. In 2024 the National Renewable Energy Laboratory was still gathering more than 50 vacuum-glazing samples from industry partners to work out failure modes and durability tests in support of ISO and ASTM standards. No published survey of old installed units was found in November 2026.
Built with what exists
A thin-film heat flux sensor and surface temperature sensors with a data logger, taped to the room side of the glass; a phone-mounted thermal camera to find cold edges; owners' records of when units were installed; buildings named in NSG's Spacia project releases as a starting list.
First step
Write to the owners of five buildings named in NSG's Spacia releases and ask to measure ten units in each this winter.
Done looks like
At least 100 vacuum units of known install year in at least 10 buildings, each with a center-of-glass U-value estimated with a stated uncertainty and set beside its rated value, and a count of units that have lost their vacuum or cracked.