Industries / Construction and property / Commercial and residential construction / Drywall
Framing
Framing is building the skeleton of thin steel or wood studs, set in floor and ceiling tracks along lines marked on the floor, that interior walls are hung from.
4
Milestones achieved, from 1950s to 2023.
0
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1950s
Screws make steel partitions work
After fires such as the 1946 Winecoff Hotel fire in Atlanta, where 119 people died, gypsum makers looked for a frame that would not burn for gypsum board partitions. Early metal studs were plain channels with metal lath wired on, and USG's Trussteel wire stud held nails only if they landed between its two wires. By the Cold-Formed Steel Engineers Institute's account, the hardened self-drilling screw, with a sharp point for thin steel or a drill point for thicker steel, and the tools developed in the 1950s to drive it, made steel stud and gypsum board partitions practical.
LessonA fastener, not a new material, turned steel framing into an everyday interior system.
Credit
the gypsum board and steel stud industries; United States Gypsum Company (Trussteel)
1970
Standards for drywall studs
ASTM C645, the US specification for nonstructural steel framing, was first published in 1970. By the account of ClarkDietrich, a stud maker, the first edition set no rules for protective coating, no marking of the studs and no screw spin-out test, all of which were added in later editions. Japan's JIS A 6517, for steel framing for walls and ceilings, was established on 1 March 1979 and revised in 2010.
LessonA standard that does not require marking leaves the buyer no way to check what was delivered.
Credit
ASTM International; Japanese Industrial Standards Committee, from a draft by the Japan Testing Center for Construction Materials and the Japanese Standards Association
2015
Thinner studs proven by test
From the mid-1990s a composite wall test, acceptance criteria AC86 of the ICBO Evaluation Service, let makers sell "EQ" (equivalent) studs: studs rolled from steel thinner than the 0.0179 in (0.45 mm) minimum in ASTM C645, stiffened by their shape and by stronger steel, and rated by the wall heights they reach in test. In 2000 the industry dropped "gauge" and began naming thickness in mils, thousandths of an inch. In 2015 the American Iron and Steel Institute published AISI S916, a test standard for such walls built from AC86. UL Solutions says EQ studs in fire-rated designs must themselves pass the fire test and carry the UL Mark, while generic studs need only meet the listed minimum thickness. ClarkDietrich says most interior drywall studs made today are EQ studs.
LessonA stud's thickness no longer tells its strength; only a tested wall does.
Credit
ICBO Evaluation Service (now ICC-ES); American Iron and Steel Institute; UL Solutions
2023
Partitions that slide in quakes
Steel stud partitions fixed to both the floor and the slab above crack when a building sways. In a 2012 shake table test of a five-story building at UC San Diego, such partitions were damaged at an interstory drift, the sideways movement of one floor relative to the next, of about 0.10%. In 2023, partitions and shaft walls built with slip tracks, top tracks in which the studs are left unfastened so the wall can slide, went through 88 earthquake motions inside a 10-story timber building on the same outdoor shake table. Most walls slid against the floor they hung from, and damage was limited to cracked joint compound and tape, damaged corner bead and some screws pulling out, at drifts of about 0.3% to 1.4%. In February 2025 Japan's Building Research Institute wrote that recent earthquakes left some buildings unusable because steel stud partitions were damaged or fell while the structure stood, and that no specific seismic design method for these walls has been established.
LessonA wall tied rigidly to two floors breaks at sways far smaller than the building's frame is designed to take.
Credit
Y. Ji, K. L. Ryan, W. Roser and S. L. Wynn (University of Nevada, Reno), T. C. Hutchinson (UC San Diego) and R. Belvin (Construction Specialties), at NHERI@UC San Diego; Building Research Institute, Japan
Open
01
Robot stands studs in track
A robot arm on a wheeled base that takes cut studs from a cart, stands each one in the floor and ceiling track at the marked layout, twists it into place and drives one screw at the bottom track, leaving the top free as in a slip track. Test it on a full-height mock partition in a workshop, with the tracks already fixed to a bench frame, so no powder-actuated tools are involved.
The briefCredit · unclaimed02
Stud thickness spot check
A public survey of the bare steel thickness of drywall studs and track as sold, measured against the thickness printed on them and the minimum in the standard or evaluation report they cite, across brands, sellers and countries.
The briefCredit · unclaimed
Open 01 · the brief
Robot stands studs in track
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A robot arm on a wheeled base that takes cut studs from a cart, stands each one in the floor and ceiling track at the marked layout, twists it into place and drives one screw at the bottom track, leaving the top free as in a slip track. Test it on a full-height mock partition in a workshop, with the tracks already fixed to a bench frame, so no powder-actuated tools are involved.
Why it is still open
Structure magazine describes robot arms that screw studs to tracks and frame steel wall panels in factories, while on site the studs are still cut to length and set on the track by hand. Searches in English, Chinese and Japanese found layout robots that mark where walls go and robots that drill ceilings, but no robot that sets studs on a building site.
Built with what exists
A collaborative arm with about 1.3 m reach, such as a Universal Robots UR10e or UR20, on a mobile base; an Intel RealSense depth camera; printed ArUco markers or the layout lines on the floor for position; a cordless screw gun on a tool mount; ROS 2 with MoveIt 2, or a policy trained from a few demonstrations (see the Note "Five demonstrations per task").
First step
Build a 2.4 m (8 ft) bench frame with floor and top track, film a framer setting 50 studs in it, and script the arm to pick up and stand one stud.
Done looks like
20 filmed partitions of 10 studs each, at 400 or 600 mm (16 or 24 in) spacing, with every stud measured against the layout (target within 3 mm, 1/8 in) and checked for plumb with a digital level, and a published tally of misplaced studs and the robot's time per stud next to a framer's.
Open 02 · the brief
Stud thickness spot check
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public survey of the bare steel thickness of drywall studs and track as sold, measured against the thickness printed on them and the minimum in the standard or evaluation report they cite, across brands, sellers and countries.
Why it is still open
The Steel Framing Industry Association's certification program sends an independent third party on unannounced plant visits to test thickness, coatings, dimensions and labels, but publishes only the list of certified plants, not the measurements. Its April 2025 bulletin gives a field method and says the minimum thickness has no tolerance, so a stud measuring under it should be rejected. In Australia, Rondo, a maker of steel framing, published in February 2025 the results of an 18-month investigation of imported studs and tracks from five suppliers, including a table from one importer's own published data in which some parts measured as little as 85% of their stated thickness, against the 95% that the AS/NZS 4600 standard requires; that is a competitor's reading of a rival's data. This research found no independent survey of studs measured as sold.
Built with what exists
A calibrated C-frame outside micrometer used as ASTM A1073 describes, read on the flat web rather than the rounded lip edges; the SFIA bulletin's table of zinc coating thickness to subtract (from ASTM A653, 1.00 oz/ft² of coating is about 1.68 mil), so no acid stripping is needed; phone photos of the printed markings; a shared spreadsheet.
First step
Buy three studs at each of five local suppliers, measure them, and post the first table with photos of every marking.
Done looks like
Three pieces each of the most common interior stud from at least 40 sellers in at least three countries, each read at five points, photographed, and classed as pass, borderline or fail against its marking and its cited minimum, published as an open table with the share that fail.