Before the machines start, crews cut off gas, power and water and take out the materials that would harm workers, neighbors or the recycled rubble, such as PCB sealants, mercury lamps and refrigerants. PCBs (polychlorinated biphenyls) are oily chemicals once used in electrical parts and building sealants, which the US Environmental Protection Agency lists as probable human carcinogens.
4
Milestones achieved, from 1978 to 2015.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1978
Ballasts marked No PCBs
A ballast is the box inside a fluorescent light fitting that controls the current. The US Environmental Protection Agency (EPA) required makers of ballasts built from 1 July 1978 to 1 July 1998 to mark those without PCBs "No PCBs". Any ballast made before 2 July 1979 may contain PCBs, and one without the mark must be assumed to. EPA's guidance for demolition tells crews to keep unmarked ballasts apart from other demolition waste, along with mercury lamps and "silent" light switches made before 1991, which may hold mercury.
Credit
US EPA, under the Toxic Substances Control Act
1984
Councils told, services cut
Under the Building Act 1984, anyone about to demolish a building in England or Wales, with exceptions such as small buildings and internal work in occupied ones, must give the local council notice and send copies to the neighbors and to the gas and electricity suppliers. Work may start once the council has replied or six weeks have passed. The council's reply can require shoring of neighboring buildings, sealing of drains, and arrangements with the utilities to disconnect gas, electricity and water.
Credit
UK Parliament
2007
Sweden clears PCB sealants
Sealants with PCBs were used in Swedish facade joints from 1956 to 1973. A Swedish ordinance of March 2007 required owners of buildings built or renovated in those years to survey sealants and floor compounds for PCBs, report by 30 June 2008, and remove them by 30 June 2016. About 25% of the properties surveyed held PCBs. A 2015 study for the Swedish Environmental Protection Agency estimated that 70 to 85% of affected properties would be cleaned by the deadline, and roughly that 20 to 50 tonnes of PCBs might remain.
Lessona voluntary campaign from 1998 to 2002 raised the work, which fell while owners waited for the law and rose again when it came; the agency concluded that both information and legislation are needed.
Credit
Swedish government; Swedish Environmental Protection Agency (Naturvårdsverket)
2015
Pollutants listed with the permit
Article 16 of Switzerland's Waste Ordinance of 4 December 2015 requires a builder applying for a permit to state the type, quality and amount of waste and where it will go, whenever more than 200 m³ of construction waste is expected, or waste containing PCBs, tar compounds (PAHs), lead or asbestos. On request, the builder must show afterwards that the waste went where the authority required. Cantons such as Aargau treat a survey of what the building holds as part of planning any demolition.
Credit
Swiss Federal Council
Watch for
EU-wide audits before demolition
The European Commission's 2026 work programme foresees a proposal for a Circular Economy Act in the third quarter of 2026. Among the policy options under study is a requirement for audits before demolition and major renovation, with a digital platform for construction and demolition waste, according to ECOS, a group of environmental organizations that works on standards. Under the EU's own guidelines, such audits cover hazardous waste as well as reusable material.
Achieved whenan adopted EU law requires audits above a set building size and member states apply it.
Claimed by
European Commission (policy option), as reported by ECOS, May 2026
Open
01
Read ballast labels by photo
A phone tool that reads the label of a fluorescent light ballast from a photo and gives one of four answers: marked "No PCBs", marked as containing PCBs, made before the cut-off date by its date code, or unknown and to be treated as containing PCBs.
The briefCredit · unclaimed02
Count hazards on a walk-through
A tool that watches a phone video of a walk through an occupied building and lists, room by room, the items a strip-out crew must take out and send separately before demolition: fluorescent tubes and other mercury lamps, fluorescent fittings whose ballasts may hold PCBs, thermostats, refrigerators, and air-conditioning units that hold refrigerant.
The briefCredit · unclaimed
Open 01 · the brief
Read ballast labels by photo
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A phone tool that reads the label of a fluorescent light ballast from a photo and gives one of four answers: marked "No PCBs", marked as containing PCBs, made before the cut-off date by its date code, or unknown and to be treated as containing PCBs.
Why it is still open
EPA says ballasts made before 2 July 1979 may contain PCBs and only those marked "No PCBs" may be assumed free of them. Where there is no mark, the date code decides, and its format differs by maker: Product Care, which runs British Columbia's light recycling program, publishes a table for more than ten makers, from Aerovox to Westinghouse, and uses 1 July 1980 as its cut-off. A search found no app or model that reads ballast labels.
Built with what exists
A phone camera; Tesseract or another text reader for the label; a small open-weight vision model fine-tuned on one GPU, such as Liquid AI's LFM3 (see the Note "One GPU to fine-tune"); the published date-code rules written as code; label photos from a lighting recycler.
First step
Ask a lighting recycler for 200 photos of ballast labels taken at intake, with no ballast opened, and class them by hand against the published table.
Done looks like
1,000 label photos, each classed by a recycler's specialist. On 300 photos held back from training, the tool calls no PCB-marked or pre-cut-off ballast free of PCBs, and the share it settles without answering "unknown" is published.
Open 02 · the brief
Count hazards on a walk-through
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A tool that watches a phone video of a walk through an occupied building and lists, room by room, the items a strip-out crew must take out and send separately before demolition: fluorescent tubes and other mercury lamps, fluorescent fittings whose ballasts may hold PCBs, thermostats, refrigerators, and air-conditioning units that hold refrigerant.
Why it is still open
EPA's guidance for demolition names mercury lamps, older silent switches and unmarked ballasts as items to isolate, and its refrigerant rules require the refrigerant to be recovered from appliances before final disposal. The TU Wien thesis of 2026 detected lamps, doors and radiators in walk-through videos, but to value them for reuse, and its detection scores were low. A search found no tool that counts the hazardous items. France's public PEMD records already list fluorescent tubes as a separate hazardous waste (code 20 01 21*), so audit forms exist to receive such counts.
Built with what exists
A phone video; an object detector such as Ultralytics YOLO11, as in the TU Wien work; CVAT to label video frames; Python.
First step
Film one floor of an office building, count the lamps, fittings, thermostats and cooling units by hand, and label 300 frames.
Done looks like