Testing checks wire and cable as it is made and before a new design is sold: conductor resistance, insulation thickness and flaws, strength against high voltage, behaviour in fire and, for new designs, long-term ageing.
6
Milestones achieved, from 1861 to 2012.
3
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1861
Testing written into contracts
A joint committee of the British Board of Trade and the Atlantic Telegraph Company found that of 11,364 miles of submarine cable laid, "little over 3,000 miles are actually working", and that the failures might have been guarded against. It recommended contracts that set the wire's conductivity against a standard wire at a set temperature, and testing each coat of insulation under water, with tests continuing while the cable was covered and laid.
Lessonmeasuring every stage beats trusting the finished cable.
Credit
Douglas Galton, C. Wheatstone and William Fairbairn for the Board of Trade; Cromwell F. Varley, Latimer Clark and others for the company
1913
One number for copper
The International Electrotechnical Commission adopted the International Annealed Copper Standard in Berlin on 5 September 1913, after the US Bureau of Standards had measured many commercial copper samples in 1910. Copper with a conductivity of 58 m per ohm-mm² at 20 °C counts as 100%; very pure wire later measured slightly over 103%.
Credit
US National Bureau of Standards; International Electrotechnical Commission
1968
Measuring tiny discharges
The IEC published its first standard method for measuring partial discharges, small sparks inside insulation that damage it over time, in January 1968. It was revised in 1981 and is now IEC 60270:2000.
Credit
IEC
1977
Cable fires tested full size
After the Browns Ferry fire, the US Nuclear Regulatory Commission paid for full-scale fire tests of cable trays at Sandia Laboratories, all on cable that had passed IEEE Standard 383-1974, a type test that includes a flame test. The tests showed "a margin of safety" in IEEE 383 qualified cable, Sandia reported.
Credit
L. J. Klamerus and R. H. Nilson, Sandia Laboratories; IEEE
2006
A spark test made equal
IEC 62230, published in May 2006, set a method for spark testing, which runs the moving cable through a high-voltage electrode to find flaws in its insulation or sheath, and treats it as equivalent to a voltage test of cable samples in water.
Credit
IEC
2012
Years of testing for DC
CIGRE's Technical Brochure 496 of 2012 set how extruded DC cable systems are qualified, with long voltage tests followed by impulse tests, and Technical Brochure 852 of 2021 extended it to 800 kV. A land cable system at 640 kV was reported qualified in 2017, CIGRE's journal Electra noted in 2023.
Credit
CIGRE working groups
Watch for
Cable for 3,000 m depths
Nexans says it has qualified a 525 kV DC cable system with paper insulation soaked in a thick compound, including its repair joint, for laying at 3,000 m of water, tested at up to 842 kN of tension after a sea trial in March 2026, and calls it a world first.
Achieved whenthe Great Sea Interconnector cable is laid at that depth and in service, or an independent laboratory confirms the tests.
Claimed by
Nexans, August 2026
Korea's first 525 kV pass
LS Cable & System says its 525 kV submarine DC cable rated for 80 °C passed the long-term prequalification test, a first in Korea, and that the higher temperature adds up to 25% transmission capacity.
Achieved whenthe test laboratory is named and publishes the result, or the cable goes into service.
Claimed by
LS Cable & System, July 2026
Gauges pooled to spot drift
Sikora's Line Performance Optimizer pools the readings of every gauge on a cable line and is "designed to detect quality fluctuations in production lines at an early stage".
Achieved whena cable maker publishes measured scrap or material savings from using it.
Claimed by
Sikora, March 2026
Open
01
Public set of extrusion defects
An open, labelled set of images of the faults an extrusion line leaves in insulation and sheaths, such as lumps, thin spots, scratches, blisters and scorch (specks of burnt plastic), with a baseline detector scored on it so camera systems can be compared.
The briefCredit · unclaimed02
Water trees counted by machine
Software that finds and measures water trees in microscope images of thin, dyed slices cut from aged cable insulation, and a public set of such images labelled by experts.
The briefCredit · unclaimed
Open 01 · the brief
Public set of extrusion defects
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An open, labelled set of images of the faults an extrusion line leaves in insulation and sheaths, such as lumps, thin spots, scratches, blisters and scorch (specks of burnt plastic), with a baseline detector scored on it so camera systems can be compared.
Why it is still open
The only public, labelled sheath image set found holds 2,400 microscope images taken from one used CAT6 network cable in a laboratory, and its author writes that it "should not be interpreted as representing cross-cable or real-world generalization".
Built with what exists
Industrial cameras with ring lights, an open labelling tool such as CVAT, and an open detector such as Ultralytics YOLO11.
First step
Ask one cable plant's quality team for the defect samples it keeps from rejected cable and photograph them in a light box at a fixed scale.
Done looks like
At least 5,000 labelled images from at least three lines and three cable types under an open licence, with a baseline's detection rate and false alarms per kilometre published.
Open 02 · the brief
Water trees counted by machine
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
Software that finds and measures water trees in microscope images of thin, dyed slices cut from aged cable insulation, and a public set of such images labelled by experts.
Why it is still open
Cable owners have long tried to judge aged cable by the number and length of its water trees, and EPRI's review notes that this "requires removal, dissection, staining and microscopy, and is very time consuming". No public labelled image set or counting tool was found.
Built with what exists
A microscope with a camera, an open labelling tool such as CVAT, and an open segmentation model such as Ultralytics YOLO11.
First step
Ask a utility or university laboratory that keeps aged cable samples for 100 stained slices it has already counted by hand, and photograph them.
Done looks like
1,000 labelled slice images from at least 20 cables, released openly, and software whose tree counts and longest-tree lengths come within 10% of an expert's on a held-out 100.