Industries / Industrial equipment and services / Industrial machinery / Wire and cable
Jacketing and armour
Jacketing puts the outer layers on a cable: sheaths that keep out water and slow fire, braids and metal screens, and wire armour that protects the cable from being crushed or cut.
6
Milestones achieved, from 1851 to 2017.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1851
Cable inside a wire rope
For the 1851 telegraph cable across the English Channel, R. S. Newall & Co. enclosed a gutta-percha core made by the Gutta Percha Company in a rope of wires. Grace's Guide records that the cable's success brought Newall's many more cable orders, and Newall's later armoured half of the 1857 Atlantic cable.
Credit
R. S. Newall & Co.; Gutta Percha Company
1955
Aluminum and plastic replace lead
Telephone cable had been sheathed in lead. Bell's Alpeth sheath, thin corrugated aluminum covered with extruded polyethylene, was in field use by 1953, and in 1955 the Bell System Technical Journal reported that in the telephone industry lead "has already been supplanted to a sizable extent" by such sheaths.
Credit
Bell Telephone Laboratories; Western Electric
1975
An exchange burns
On 27 February 1975 a five-alarm fire broke out at New York Telephone's Second Avenue exchange in Manhattan, started by a short circuit in a basement cable vault. 208 cables in the vault were charred and melted and more than 170,000 lines went dead for three weeks. Hackaday describes black smoke from miles of burning PVC-insulated cable and links the later rules for "plenum-rated" cable partly to the fire.
Lessonwhat a cable gives off when it burns matters as much as whether it burns.
Credit
New York Telephone, which restored the exchange
1975
A candle lights cable trays
On 22 March 1975 workers at the Browns Ferry nuclear plant checked for air leaks with a lit candle, which set fire to seal material and the cables running through it. More than 1,600 cables were affected, 628 of them important to plant safety, and the US Nuclear Regulatory Commission says the fire "fundamentally changed" how it dealt with fire protection.
Lessoncables packed together in trays can carry a fire through a plant.
Credit
reported by the US Nuclear Regulatory Commission
2014
Printed ratings fail tests
The Communications Cable and Connectivity Association, a group of cable makers, had a nationally recognized test laboratory test 17 Category 5e and 6 cables from 12 unfamiliar brands sold in the US. Seven of the nine riser-rated cables failed the flame spread test, most of the eight plenum-rated ones did too, and all 17 failed the smoke tests, it reported in 2014.
Lessona fire rating printed on a jacket is a claim until someone tests it.
Credit
Communications Cable and Connectivity Association
2017
Fire classes for EU cable
From 1 July 2017, cable sold in the EU for fixed installation in buildings had to carry a reaction-to-fire class under the Construction Products Regulation and the standard EN 50575. Commission Delegated Regulation (EU) 2016/364 set seven classes, Aca to Fca, with extra grades for smoke, flaming droplets and the acidity of the fumes.
Credit
European Commission; CENELEC
Watch for
Fluoropolymer jackets under review
The EU's proposed restriction of PFAS, the "forever chemicals", moved forward when the European Chemicals Agency's risk committee adopted its final opinion on 2 March 2026 and its socio-economic committee published a draft. Both reject a grouped exemption for fluoropolymers, the plastics used in plenum cable jackets in North America.
Achieved whenthe European Commission adopts the restriction and publishes it in the Official Journal.
Claimed by
the European Chemicals Agency's committees, March 2026, as reported by Linklaters
Robots load braiding bobbins
Niehoff says a braiding machine of the kind that weaves metal screens over cable cores will be shown with a bobbin winder, a self-driving cart and "a robotic handling system that loads and unloads braiding bobbins automatically". No figures are given.
Achieved whenit runs in production at a named customer with measured results.
Claimed by
Maschinenfabrik Niehoff, March 2026
Open
01
One register of fire classes
A public table of every cable sold in the EU for fixed installation in buildings, one row per declaration of performance, with the maker, the product, its fire class with the smoke, droplet and acidity grades, the notified body that tested it, and a link to the declaration itself.
The briefCredit · unclaimed02
Yearly tests of online cable
A public test, repeated every year, of network and building cable bought from online marketplaces: whether the conductor is solid copper or copper-clad aluminum, its resistance per 100 m, its insulation and jacket thickness, and whether its printed fire rating is backed by a listing and a test.
The briefCredit · unclaimed
Open 01 · the brief
One register of fire classes
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public table of every cable sold in the EU for fixed installation in buildings, one row per declaration of performance, with the maker, the product, its fire class with the smoke, droplet and acidity grades, the notified body that tested it, and a link to the declaration itself.
Why it is still open
Each maker publishes its own declarations; Helukabel, for one, runs a lookup for its own products only. The EU's revised regulation will put declarations of performance into a digital product passport, but the old and new regulations will coexist for years and the old one is not repealed until 2039.
Built with what exists
A web agent that writes its own scraper code, such as Browser Use 1.0 (Note "Deleting 80% to start over"), PDF text extraction, and a small model for pulling fields out of documents (Note "The jobs agents repeat").
First step
Collect the declarations from three makers' own lookups and fix the column list.
Done looks like
At least 2,000 declarations from at least 20 makers, each row linked to its source, with 100 rows picked at random and checked by hand and the error count published.
Open 02 · the brief
Yearly tests of online cable
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public test, repeated every year, of network and building cable bought from online marketplaces: whether the conductor is solid copper or copper-clad aluminum, its resistance per 100 m, its insulation and jacket thickness, and whether its printed fire rating is backed by a listing and a test.
Why it is still open
The best-known test, commissioned by the Communications Cable and Connectivity Association and reported in 2014, covered 17 cables from 12 unfamiliar brands, all of which failed the smoke tests. No repeated independent test was found.
Built with what exists
A four-wire milliohm meter, a micrometer and a stereo microscope for thickness, a rented cable certification tester, a check of each printed listing number against the listing body's online directory, and flame and smoke tests bought from an accredited laboratory.
First step
Buy ten boxes sold as Category 6 from the cheapest listings and measure each conductor's resistance and material.
Done looks like
Fifty boxes from at least five marketplaces tested each year, every result posted with photos and the listing as it appeared on the day of purchase.