Industries / Energy, water and waste / Power generation / Solar panels
Inverters and mounting
Inverters turn the direct current (DC) that panels make into the alternating current (AC) the grid uses, and mounting is the steel racking, fixed or motorized, that holds the panels up.
7
Milestones achieved, from 1995 to 2025.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1995
One inverter per string
SMA put its Sunny Boy 700 on sale in 1995 and calls it the first string inverter: one small inverter for each string, a chain of panels wired one after another. SMA lists its efficiency (the share of the power going in that comes out as usable AC) at 93.4%, against 90% for its first inverter of 1990, and credits string technology with simpler installation.
Credit
SMA Solar Technology
2003
Rules for plugging in
UL, the US safety-testing company, published UL 1741, its safety standard for solar inverters, in May 1999, and the IEEE published IEEE 1547 in 2003 to set how small generators such as rooftop solar interact with the grid. Under these rules an inverter had to watch the grid's voltage and frequency (how many times a second the current reverses) and disconnect within set times if either drifted even slightly from normal.
Credit
Underwriters Laboratories; IEEE
2008
An inverter per panel
Enphase Energy began commercial shipments of microinverters, small inverters fitted under each panel, in mid-2008. By May 2011 it had shipped more than 750,000 units, and its share of California's home solar inverter market, by California Solar Initiative data, had risen from 0% to almost 20%.
Credit
Enphase Energy
2012
Germany resets 400,000 systems
Much of Germany's solar capacity was set to switch off as soon as grid frequency rose to 50.2 Hz, which a surplus of power can cause, so all of it could have dropped off at once. A 2012 measure required new frequency settings on new and existing systems, and by August 2014 about half of the roughly 400,000 affected systems had been retrofitted, according to Germany's Renewable Energies Agency. Systems of 10 kW or less were exempt.
Lessona safety setting that is sensible for one inverter becomes a risk when hundreds of thousands share it.
Credit
German federal government (rule); grid operators, installers and inverter makers (retrofit)
2016
A wildfire trips 1,200 MW
On 16 August 2016 the Blue Cut fire in California caused faults on major transmission lines, and solar plants with nearly 1,200 MW of output stopped producing, although none had been cut off by the faults themselves. NERC, the body that sets reliability rules for North America's grid, found that inverters had tripped on near-instant frequency readings distorted by the fault, and the inverter makers involved recommended a time delay so that inverters "ride through" such brief disturbances. The 2018 revision of IEEE 1547 requires inverters to ride through brief voltage and frequency swings.
Lessoninverters that trip at the first sign of trouble can turn a short fault into a large loss of power.
Credit
NERC (investigation); the inverter makers involved (setting changes)
2017
Shutdown at the panel
The 2014 US National Electrical Code added rapid shutdown, so that firefighters are not shocked by live wiring: on buildings, conductors more than 10 feet from the array had to drop to 30 V or less within 10 seconds (later 30) of shutdown. The 2017 edition shrank that boundary to 1 foot and added rules inside the array, where one of three ways to comply is to bring conductors down to 80 V or less within 30 seconds. The only products ready for that option were devices fitted under each panel, such as microinverters and DC optimizers (small converters that tune each panel's output), which made them a de facto requirement, by the account of two SMA engineers.
Credit
NFPA, publisher of the National Electrical Code
2025
Trackers become the default
Single-axis trackers are motorized racks that turn rows of panels to follow the sun across the sky. Berkeley Lab found that 96% of new US utility-scale solar capacity built in 2025 used them, after rapid growth from 2020. Tracking adds more than five percentage points to a plant's capacity factor (its output as a share of the most it could make), and the extra up-front cost of trackers had faded.
Credit
tracker makers; Lawrence Berkeley National Laboratory (data)
Watch for
EU limits on risky suppliers
In January 2026 the European Commission proposed a revised Cybersecurity Act under which it could name countries that pose serious cybersecurity risks and restrict their suppliers, and in April 2026 it began restricting EU funds for projects that use inverters from "high-risk suppliers". In October 2026 an expert group advising the Commission recommended restricting such suppliers' parts and software in every segment of the solar market and requiring third-party certification of inverters; it also said an attack through a maker's built-in backdoor "has not yet occurred in practice".
Achieved whenthe revised Act is adopted and a first inverter supplier is restricted under it.
Claimed by
European Commission, January 2026; the Commission's Smart Energy Expert Group, October 2026
Gallium nitride microinverters
Enphase says it began shipping its IQ9N-3P commercial microinverter across the US in late December 2025, its first product to use gallium nitride (GaN) switches in place of silicon ones, which it says switch faster and run cooler. It states 97.5% efficiency and a peak output of 427 VA.
Achieved whenan independent test lab publishes the product's measured efficiency, or field data on its failure rate are published.
Claimed by
Enphase Energy, January 2026
Open
01
An open inverter teardown registry
A public registry of opened inverters. For each model: photographs of every circuit board, a list of every radio or modem chip (Wi-Fi, cellular, Bluetooth and others) read from its markings, and a column comparing that list with the radios the maker declares in its manual and its radio filings, such as the US FCC's equipment database. Work only on units that are not connected to anything.
The briefCredit · unclaimed02
Where inverter data goes
A public table, brand by brand, of the internet addresses that home inverters and their monitoring dongles contact, where those servers are hosted, and which ones deliver firmware updates. Data comes only from owners passively logging their own, professionally installed systems on their own home networks, with no probing of any maker's servers.
The briefCredit · unclaimed
Open 01 · the brief
An open inverter teardown registry
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public registry of opened inverters. For each model: photographs of every circuit board, a list of every radio or modem chip (Wi-Fi, cellular, Bluetooth and others) read from its markings, and a column comparing that list with the radios the maker declares in its manual and its radio filings, such as the US FCC's equipment database. Work only on units that are not connected to anything.
Why it is still open
In 2025 Reuters reported, from unnamed US officials and later a Federal Highway Administration note, that undeclared radios had been found in some inverters, naming no makers or models; nearly six months after the first report, the cybersecurity expert Uri Sadot told pv magazine there was still no "public, well-documented teardown." In January 2026 pv magazine reported that the US Department of Energy's national laboratories had inspected about 30 inverters and found two whose communications differed from their documents, both judged "non-malicious" and "non-intentional"; the analysis went to energy-sector partners, and pv magazine saw it, but no models or photographs were made public. GitHub searches for "inverter teardown" and "solar teardown" found no repositories.
Built with what exists
Hand tools and an anti-static mat; a USB microscope or a phone macro lens for chip markings; the FCC equipment authorization search and the EU declarations of conformity for declared radios; a vision-language model to transcribe chip markings, with each one checked by a person; a public GitHub repository.
First step
Buy two used home string inverters from different makers, open them after the maker's stated discharge time, and log every chip.
Done looks like
30 models from at least 10 brands, each with board photographs, a chip list checked by a second person, and a yes or no on whether every radio found is declared; anyone can match each listed chip to a photograph.
Open 02 · the brief
Where inverter data goes
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public table, brand by brand, of the internet addresses that home inverters and their monitoring dongles contact, where those servers are hosted, and which ones deliver firmware updates. Data comes only from owners passively logging their own, professionally installed systems on their own home networks, with no probing of any maker's servers.
Why it is still open
The European Commission's expert group warned in October 2026 of a "split operational architecture", in which monitoring dashboards are hosted in the EU while firmware updates, signing and remote control run from countries it considers high-risk, but its report names no country or company. The nearest measurement is Trend Micro's January 2024 study of five home energy gateways (from Enphase, OutBack, Phocos, Sol-Ark and Victron), which captured where each sends data, as of July 2023; it covered those five brands only. GitHub searches for "inverter traffic" and "inverter cloud" found only home-automation plug-ins that poll vendor clouds, not a map.
Built with what exists
Pi-hole or router DNS logs; Wireshark or Zeek on a mirrored port of a home switch; IP-to-country data such as MaxMind GeoLite2 or RIPEstat; a shared repository and a short consent form for volunteers.
First step
Install Pi-hole at one home with a solar inverter and log a week of its lookups.
Done looks like