Industries / Construction and property / Real estate / Self-storage
Climate, fire and flood
This work is keeping stored goods safe from damp, heat, fire and water, and saying plainly what protection a unit gives.
5
Milestones achieved, from 1991 to 2024.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1991
Nevada defines climate control
Since 1991 Nevada law has barred a storage owner from advertising a facility as "climate controlled" unless the advertisement gives the minimum and maximum temperature and humidity at which it is kept. An owner who leaves out the range, or fails to hold it, commits a misdemeanor and is liable for damage the extremes cause, whatever the rental agreement says (NRS 597.890, amended 2011). In 2008 a storage lawyer wrote in Inside Self-Storage that Nevada was the only state with such a law and that the term had no national or state definition elsewhere.
Credit
Nevada Legislature
2006
Japan counts damp complaints
In Japan, the "trunk rooms" of warehouse companies registered under the Warehousing Business Act, which hold goods under a deposit contract, can be certified by the transport minister for set kinds of protection: steady temperature (for liquor), steady humidity (lacquerware), dust (precision instruments), pests (furs) and magnetism (disks); other firms simply rent out space. In a survey for the ministry published in March 2006, about 1% of users of warehouse companies' trunk rooms were unhappy with temperature, humidity, dust and pest protection, against about 12% of users of rented space, and complaints to consumer centres were most often about mold, soiling and dust. Japan had 910 certified trunk rooms that year.
LessonGoods held under a contract that names the protection drew far fewer damp complaints than goods left in rented space.
Credit
Ministry of Land, Infrastructure, Transport and Tourism (MLIT)
2007
Humidity is the hard part
For a US design guide meant to cut energy use 30% below the 1999 edition of the ASHRAE 90.1 energy standard, Pacific Northwest National Laboratory (PNNL) modelled an 8,000 ft² self-storage building whose units were air-conditioned to control temperature and humidity. In the first round of models the savings reached only 19.6% in Duluth and 23.2% in Phoenix; the authors traced the shortfall to the humidity limit, and the guide answered with measures such as heat pumps with variable-speed fans and compressors.
LessonIn the models it was holding humidity down, not heating or cooling, that kept storage from the energy target.
Credit
B. Liu, R. E. Jarnagin, W. Jiang and K. Gowri, PNNL, for the US Department of Energy's Advanced Energy Design Guide for Small Warehouses and Self-Storage Buildings
2018
1,198 units lost in Croydon
On 31 December 2018 fire destroyed all 1,198 units of Shurgard's four-storey storage building on Purley Way, Croydon, in south London; about 125 firefighters and 20 engines attended. The London Fire Brigade had audited the building in 2012 and 2016 and found it broadly compliant. In February 2019 the London Assembly voted unanimously for an urgent review of how self-storage is regulated, saying the fire had exposed "a potential vacuum of regulatory framework". Shurgard rebuilt the site with sprinklers and a water tank; the planning report says the sprinklers forced taller floors and a flat roof.
Credit
London Fire Brigade; London Assembly; Shurgard
2024
Flooded outside the floodplain
Hurricane Helene's floods in September 2024 destroyed the units of a storage facility in Morganton, North Carolina, where 158 of 160 units were rented. It had run since the 1970s without a flood, and its broker said it was not in a floodplain; the business had no flood insurance and had not required tenants to insure their goods. Around Asheville the operator SmartStop closed all 15 of its sites and said one was badly flooded.
LessonA site outside the mapped floodplain can still flood, and the goods are lost unless someone insured them.
Credit
reported by The Paper of Morganton and by Modern Storage Media
Watch for
Solar on 1,300 storage roofs
Public Storage says that at the end of 2025 more than 1,060 of its properties had rooftop solar panels, generating about 76.0 million kWh, and that it will reach 1,300 by the end of 2026. The leaderboard it cites as recognition, Black Bear Energy's, tracks projects that companies report themselves.
Achieved whena count made outside the company, from utility connection records or aerial photographs, confirms the number of roofs and the output.
Claimed by
Public Storage, June 2026
Open
01
Climate claims checked
A public table of what storage operators promise when they call a unit "climate-controlled": the temperature range, the humidity range if any, backup power, and what the rental agreement says happens when the system fails. It is coded from operators' websites and agreements, and every Nevada listing is checked against Nevada's law.
The briefCredit · unclaimed02
An energy yardstick for storage
A public benchmark of energy use per square foot for self-storage buildings, split by how much of each building is climate-controlled and by climate, built from the energy reports that cities require large buildings to publish.
The briefCredit · unclaimed
Open 01 · the brief
Climate claims checked
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public table of what storage operators promise when they call a unit "climate-controlled": the temperature range, the humidity range if any, backup power, and what the rental agreement says happens when the system fails. It is coded from operators' websites and agreements, and every Nevada listing is checked against Nevada's law.
Why it is still open
Outside Nevada no US state defined the term, a storage lawyer wrote in 2008; in his example one site means 72 °F and 54% humidity held all year and another an exhaust fan switched on above 90 °F. In October 2026 WDIV Local 4 in Detroit reported tenants at two Public Storage sites who found mold in climate-controlled units, one of whom showed a reading of about 60% humidity at 67 °F. This research found no published survey of what the claims promise.
Built with what exists
A browser agent to collect listings and rental agreements (see the Note "Deleting 80% to start over"); an AI model that pulls fixed fields out of long text (see the Note "The jobs agents repeat"); a model that answers fixed yes-or-no questions in bulk (see the Note "A thousand questions, one pass"); a person checking a random sample.
First step
Code by hand the climate-control wording of 50 listings in Las Vegas and 50 in Miami.
Done looks like
At least 1,000 facility listings from 20 or more operators in five US states and two other countries, each coded for its stated temperature and humidity ranges; Nevada listings marked as meeting NRS 597.890 or not; a 10% sample checked by hand with at least 95% agreement; data and code public.
Open 02 · the brief
An energy yardstick for storage
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public benchmark of energy use per square foot for self-storage buildings, split by how much of each building is climate-controlled and by climate, built from the energy reports that cities require large buildings to publish.
Why it is still open
The US EPA's ENERGY STAR Portfolio Manager gives self-storage a national median of 20.2 kBtu per square foot of site energy (47.8 kBtu of source energy), borrowed from its survey data for non-refrigerated warehouses (table dated August 2024). New York City's 2024 filings under Local Law 84 list 354 buildings whose main use is self-storage; in this research's count of the 330 with a positive figure, site energy ran from 4.7 kBtu per square foot at the 10th percentile to 40.9 at the 90th, with a median of 13.4. No published benchmark separating climate-controlled space was found.
Built with what exists
NYC Open Data's Local Law 84 dataset through its public API; the disclosure data of other cities that use Portfolio Manager's property types; operators' listings to estimate each building's climate-controlled share; NOAA heating and cooling degree days; Python with pandas.
First step
Download New York's 2024 self-storage rows and match 50 of them to operators' web pages to record their climate-controlled share.
Done looks like
At least 1,000 building-years from at least four cities, each matched to a climate-controlled share checked against the operator's listing; median energy use per square foot by share band and climate, with ranges; the matching table and code public.