These are the systems that make an RV livable away from a house: 12 V battery power and the 120 V or 230 V shore supply, the bottled gas (liquefied petroleum gas, or LPG) for heat and cooking, and the tanks, pumps and pipes for fresh water and waste.

6

Milestones achieved, from 1963 to 2023.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1963

    A black tank valve

    A black tank holds an RV's toilet waste until it is emptied at a dump station. Thetford says that in 1963 Frank Sargent and his two sons, unhappy with the drain valve on their own RV's black tank, designed the first slide-action valve for RV holding tanks in a garage in Thetford Township near Flint, Michigan, and founded Thetford Engineering. In the next three years the firm developed what it calls the first low-profile and the first low-water-use RV toilets.

    thetford.com

    Credit

    Frank Sargent and sons, Thetford

  2. 2000

    A 12-volt rulebook

    RVs run their lights, pumps and controls on 12 V battery power, and part of that wiring comes from the maker of the chassis and part from the maker of the RV. In the late 1980s and early 1990s it followed the low-voltage rules in Article 551 of the US National Electrical Code (NEC), but those rules did not let the two makers design systems that worked together. Automotive companies, conversion-van makers and state enforcement officials wrote a separate standard, first published in 1992 for conversion vans. The 2000 edition extended it to RVs, and the 2005 edition required listed (third-party certified) wire. In November 2025 the RV Industry Association (RVIA) adopted its 2025 edition, retitled the Standard for DC Voltage Systems in Recreational Vehicles, with enforcement from 1 September 2026.

    Lessona vehicle wired by two companies needed one set of rules both could design to.

    ia601909.us.archive.orgrvia.org

    Credit

    RVIA and its standards committees

  3. 2004

    Gas heat while driving

    A European Commission directive of 29 April 2004 (2004/78/EC) set the terms on which an LPG heater in a motorhome may run while the vehicle moves. The heater must meet EN 624, the standard for sealed gas heaters in vehicles and boats; the gas pipework must meet EN 1949, the European standard for LPG systems in leisure vehicles; and a device must stop the gas so that "no uncontrolled release due to an accident can occur". From 1 January 2006, new vehicle types that did not comply could no longer be type-approved. Truma launched its MonoControl CS and DuoControl CS gas regulators, which have a built-in crash sensor, in 2010.

    legislation.gov.uklegislation.gov.uktruma.com

    Credit

    European Commission; Truma

  4. 2020

    Lithium inside the coach

    Lithium iron phosphate (LiFePO4) house batteries last longer and hold more energy for their size than lead-acid ones, and unlike lead-acid batteries they do not give off hydrogen while charging. The RV low-voltage standard first dealt with lithium batteries in its 2018 edition; the 2020 edition added rules for lithium systems and solar panels and raised the top of "low voltage" to 60 V DC. A lithium battery must be listed by a third-party agency that RVIA recognizes, which checks its protection against thermal runaway (overheating that feeds on itself), its battery management system, its current limits and its cell balancing. In September 2020 RVIA's board let non-vented lithium batteries sit inside the living space without a vented box, as long as labels warn owners not to swap in a vented lead-acid battery.

    rvia.orgia601909.us.archive.org

    Credit

    RVIA Standards Steering Committee

  5. 2022

    Safety switches for DC faults

    A residual current device (RCD) cuts the power when current leaks to earth, for example through a person. In Australia and New Zealand, AS/NZS 3001.2:2022, the standard for connectable electrical installations, which has sections on recreational vehicles, requires "Type A" RCDs (section 3.5.4). The Electrical Regulatory Authorities Council (ERAC), through which the electrical regulators of every Australian state and territory and of New Zealand speak, says that since 1 May 2023 the older "Type AC" RCDs may not be installed in Australia, because of the growing use of electronics and solar equipment whose currents carry a DC component.

    erac.gov.austore.standards.org.au

    Credit

    Standards Australia and Standards New Zealand; ERAC

  6. 2023

    A rule before its device

    "Hot skin" is when an RV's metal body or frame becomes live, usually because the ground connection has been lost through a damaged cord, a faulty adapter or a bad campground outlet. The 2020 NEC required ground-fault breakers (GFCIs) on campground 30 A and 50 A outlets, but a tentative interim amendment, effective on 26 December 2019, limited them to 15 A and 20 A outlets, noting that appliances in an RV create leakage currents; RVIA says that leakage would make GFCIs trip when nothing is wrong. The 2023 NEC instead required every RV with 30 A or 50 A service to carry a loss-of-ground device from 1 January 2026, though no such device existed. UL published an outline for grounding monitor interrupters (GMIs), UL 2299, on 26 January 2024, and the 2026 NEC named the device, but when RVIA delayed enforcement in November 2025 there were still no listed GMIs ready for RV production.

    Lessona rule that needs a device nobody makes has to wait for the device.

    ecmweb.comrvia.orgrvnews.comrvia.org

    Credit

    NFPA's Code-Making Panel 7; RVIA; UL

Watch for

  1. Ground monitors in new RVs

    A GMI checks an outlet's ground connection before it lets power into the RV, and cuts the power if the ground is lost. In June 2026 RVIA's board made GMIs a requirement for all new RVs with 30 A or 50 A service from 1 January 2027, enforced from the start of each maker's model-year 2028 production; its standards committee expects enough listed GMIs to be available by then.

    Achieved whenGMIs listed to UL 2299 are fitted on production RVs and checked in RVIA's plant inspections, and field reports show how often they trip and what faults they catch.

    rvia.org

    Claimed by

    RV Industry Association, June 2026

Open

  1. 01

    Tank gauges, tested

    A bench rig with a see-through RV holding tank fitted with the common kinds of level gauge, the stock screw-in probes, an external sensing strip, an ultrasonic sensor and a pressure sensor, filled in measured steps first with clean water and then with a fouling mix, logging each gauge's reading against the true level.

    The brief
    Credit · unclaimed
  2. 02

    Leakage in RVs, measured

    A public table of how much current leaks to ground from RVs and their appliances, and whether each RV trips a ground-fault breaker (GFCI) on a 30 A or 50 A supply, with each appliance switched on in turn.

    The brief
    Credit · unclaimed

Open 01 · the brief

Tank gauges, tested

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A bench rig with a see-through RV holding tank fitted with the common kinds of level gauge, the stock screw-in probes, an external sensing strip, an ultrasonic sensor and a pressure sensor, filled in measured steps first with clean water and then with a fouling mix, logging each gauge's reading against the true level.

Why it is still open

MotorHome Magazine wrote that "the vast majority of holding tank gauges leave a lot to be desired", and blamed probes that corrode and collect residue. Searches of the web and GitHub in November 2026 found no independent bench test of RV tank gauges, only owners' forum reports and makers' claims.

rv.com

Built with what exists

A translucent polyethylene RV holding tank; a stock four-probe gauge and monitor panel; Garnet's SeeLevel II external strip; an ultrasonic distance sensor and a pressure transducer; a 12 V bench power supply; a scale to measure the water by weight; an Arduino or Raspberry Pi to log readings; clean water and a fouling mix of RV toilet paper and a grease simulant, never real sewage.

  1. First step

    Buy one tank and one stock probe gauge, mark the tank in 10% steps by weight of water, and log the probe readings through one clean fill.

  2. Done looks like

    Each gauge's error, in percent of tank volume, at 10 levels from empty to full, clean and again after 30 fill-and-drain cycles with the fouling mix, for at least four gauge types and three units of each, published with raw logs and photos.

Open 02 · the brief

Leakage in RVs, measured

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of how much current leaks to ground from RVs and their appliances, and whether each RV trips a ground-fault breaker (GFCI) on a 30 A or 50 A supply, with each appliance switched on in turn.

Why it is still open

The 2020 NEC's GFCI requirement for campground 30 A and 50 A outlets was cut back by an amendment noting that appliances in RVs create leakage currents, and RVIA says the idea was dropped because that leakage would cause nuisance trips. The RV electrical writer Mike Sokol explains how leakage from several appliances adds up past a GFCI's 5 mA (milliampere) limit. Searches of the web and GitHub in November 2026 found no published measurements of how much RVs leak or how many would trip.

ecmweb.comrvia.orgrvelectricity.substack.com

Built with what exists

A GFCI-protected 30 A and 50 A test pedestal installed and checked by a licensed electrician at a dealer's lot or a campground; a leakage-current clamp meter such as the Fluke 369 FC, used by that electrician; the RVs' own switches to turn appliances on one at a time; a shared spreadsheet. The person running the study plugs RVs in and records results, and does no wiring.

  1. First step

    Ask one dealer and one licensed electrician to set up a single GFCI test pedestal, and test five units on the lot.

  2. Done looks like

    50 RVs from at least 10 brands and three model years tested, each with its trip or no-trip result and its leakage in milliamperes with each appliance on, published with a ranking of the appliance types that leak most.