Industries / Industrial equipment and services / Industrial services / Pump and valve repair
Field service
Field service is repair work done where a pump or valve is installed, often while the rest of the plant keeps running: sealing leaks under pressure, lining up a pump with its motor, and taking off or refitting the actuator or gearbox that turns a valve.
6
Milestones achieved, from 1920 to 2025.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1920
Leaks sealed while running
By TEAM's account, Eugene Clay Furman developed a way to seal leaks while the line stayed under pressure at the Newport News Shipyard in Virginia in 1920, sold do-it-yourself kits from 1924 that won acceptance after a favorable US Navy review, and turned his company to a sealing service with its own technicians in 1929; for many years the method worked only on low-pressure steam, about 6 bar (87 psi). Other firms now sell the same service for leaking flanges, valves and pumps: Hydratight describes fitting a custom clamp around the leak and injecting sealant into it while the system stays live.
Credit
Eugene Clay Furman and his company Furmanite, now part of TEAM
1984
Lasers line up shafts
A pump and the motor that drives it are joined by a coupling, and their two shafts have to be lined up to fine tolerances. Prüftechnik of Germany says it introduced the world's first laser-optical shaft alignment system, OPTALIGN, in 1984. The job is now set down in a national standard: ANSI/ASA S2.75-2017 Part 1 gives methods, practices and tolerances for measuring and correcting the alignment of flexibly coupled machines, naming an electric motor driving a pump as an example.
Credit
Prüftechnik; the Acoustical Society of America's standards program, for S2.75
1999
Repaired while it ran
On 23 February 1999 at Tosco's Avon refinery in Martinez, California, workers were replacing corroded naphtha piping 112 feet (34 m) up a fractionator tower while the unit kept running. Naphtha released onto the hot tower and ignited, killing four men and seriously injuring a fifth. Shut-off valves on the line had malfunctioned repeatedly and drain valves were clogged, so the pipe could not be isolated or drained, and a maintenance supervisor had decided to do the job without shutting the unit down.
LessonValves that keep leaking cannot be trusted to isolate equipment for repair; when isolation cannot be proved, the process has to be shut down first.
Credit
investigated by the US Chemical Safety and Hazard Investigation Board (CSB), final report approved 21 March 2001
2016
The wrong four bolts
On 22 November 2016 at ExxonMobil's Baton Rouge refinery, an operator removed a broken gearbox from a plug valve, a valve opened and closed by a quarter turn of a plug with a hole through it, so that he could turn the stem with a pipe wrench. On this older design, the four bolts that held the gearbox bracket also held the top cap that keeps the valve under pressure. When he turned the stem the valve came apart, and the isobutane it released ignited within 30 seconds and severely burned four workers. The CSB found that 15 of the roughly 500 gear-operated plug valves in the unit were of this design, which the maker, Durco, had changed in 1984, and that removing a gearbox was accepted practice with no written procedure or training.
LessonThe CSB's key lessons were to design out the chance of a dangerous mistake where possible, and to give workers written procedures and training for every task they are expected to do.
Credit
CSB safety bulletin, September 2017
2021
The same mistake again
On 27 July 2021 at LyondellBasell's La Porte complex in Texas, three contract workers were removing the actuator, the powered unit that turns a valve, from a plug valve so that the valve could isolate a pipe for repair. They removed bolts that held the valve's pressure-retaining parts, the plug was forced out, and about 164,000 pounds (74 metric tons) of acetic acid mixture erupted, killing two of them. The valve was of a newer design meant to let the actuator come off without disturbing the pressure parts, and the CSB listed four earlier cases of the same error, the first at Puebla, Mexico, in 1977.
LessonA design meant to prevent the error had not stopped it, so the CSB asked the valve standards bodies to make it hard to do on new valves and to mark the pressure-retaining parts on old ones.
Credit
CSB final report, 25 May 2023
2025
Plug valve bolts get labels
In October 2025 the American Petroleum Institute (API) published the 9th edition of API Standard 599, its standard for metal plug valves, with a warning about these incidents, a requirement to label the fasteners that hold pressure, and an updated requirement to prevent pressure-retaining parts from coming off with an actuator or gearbox. The CSB accepted this in January 2026 as meeting most of its recommendation, but API said the standard covers only the design and manufacture of new valves, not valves already installed.
Credit
API's Subcommittee on Piping and Valves; the CSB, which asked for the change
Watch for
A guide for existing valves
The CSB asked the Valve Manufacturers Association of America (VMA) for a white paper recommending, as good practice, that plants write a removal procedure for each plug valve design they use and clearly mark the pressure-retaining parts of valves already in service. VMA has given the CSB a planned action with a written timetable, which the Board judged would meet the recommendation once carried out.
Achieved whenthe white paper is published and the CSB closes recommendation 2021-05-I-TX-R6.
Claimed by
VMA, in a CSB status change dated August 2026
Open
01
Map the pressure-holding bolts
A free, printable guide for plug valves already installed in plants. For each common plug valve and actuator bracket design it gives one drawing that marks which bolts hold the valve's pressure parts and which hold only the actuator or gearbox, taken from the maker's manual, with a matching paint-marking scheme. It is tested with trainees on display valves that have never been connected to a line.
The briefCredit · unclaimed02
Check alignment with a camera
A phone app that measures how far a pump shaft is out of line with its motor shaft, from video of printed targets clamped to the two coupling halves while the shafts are turned slowly by hand, on a training rig that is never powered during the test.
The briefCredit · unclaimed
Open 01 · the brief
Map the pressure-holding bolts
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A free, printable guide for plug valves already installed in plants. For each common plug valve and actuator bracket design it gives one drawing that marks which bolts hold the valve's pressure parts and which hold only the actuator or gearbox, taken from the maker's manual, with a matching paint-marking scheme. It is tested with trainees on display valves that have never been connected to a line.
Why it is still open
The CSB counted five incidents of the same error from 1977 to 2021. The 2025 edition of API 599 requires labels on new valves only, and API said existing valves are outside its scope. VMA's guidance for existing valves was still a planned action in August 2026, and the CSB's recommendation to ASME for its valve standard B16.34 was awaiting a response. The nearest thing to a map is a one-page Process Safety Beacon from the Center for Chemical Process Safety (April 2025), whose photos highlight the actuator bracket bolts and the pressure-retaining cover bolts of the La Porte valve alone. No public guide that maps the fasteners of the installed designs was found.
Built with what exists
Makers' published installation and maintenance manuals, such as Flowserve's Durco plug valve documents that the CSB cites; an AI model that reads exploded parts drawings, such as Claude Fable 5.2 (see the Note "Three working devices"), with every callout checked by hand; Inkscape for the drawings; surplus plug valves bought for display and never put under pressure.
First step
List the valve designs named in the CSB's five incident accounts, download their makers' manuals, and draw the first three sheets.
Done looks like
Sheets for at least 20 plug valve designs, each checked against the maker's manual by a second person; a timed test in which at least 30 trainees each pick the actuator bolts on five display valves, once without the sheets and once with them, with the error rates published.
Open 02 · the brief
Check alignment with a camera
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A phone app that measures how far a pump shaft is out of line with its motor shaft, from video of printed targets clamped to the two coupling halves while the shafts are turned slowly by hand, on a training rig that is never powered during the test.
Why it is still open
Alignment kits that work with a phone use it as a screen and calculator, not as the sensor. SKF's TKSA 11, for example, measures with two inductive proximity sensors and sends the readings to an iPhone or iPad over Bluetooth. A web search and a search of the Crossref paper index in November 2026 found laser-based ways to measure misalignment but no camera-only method tested against a laser tool.
Built with what exists
OpenCV's ArUco marker detection and camera calibration; a phone that records 4K video; printed targets on magnetic brackets; a motor and pump training rig with shims and adjusting bolts; a laser alignment tool as the reference; the tolerance tables of ANSI/ASA S2.75-2017 Part 1 to judge the results.
First step
Print ArUco targets, clamp them to the coupling of a training rig or a spare pump set, film one full turn, and see how small a shift the software can detect.
Done looks like
50 rig setups of known misalignment, each measured by the app and by the laser tool, with the app's offset within 0.05 mm and its angle within 0.05 mm per 100 mm of the laser's in at least 45 of the 50; code, videos and readings published.