BRENNEN

Industries / Industrial equipment and services / IoT and industrial automation

Networks

Industrial networks carry readings and commands between sensors, controllers and computers, on timetables the machines can rely on.

7

Milestones achieved, from 1979 to 2022.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1979

    A protocol that lasted

    Modicon published Modbus, a serial protocol (a set of rules for messages on a cable) for controllers to exchange readings, in 1979, and it "continues to be used," a 2011 history in Manufacturing AUTOMATION notes.

    automationmag.com

    Credit

    Modicon

  2. 1985

    GM's network falls short

    General Motors, which bought equipment from more than 100 vendors without a common standard, backed the Manufacturing Automation Protocol (MAP), a factory network on token-bus cabling. At the 1985 Autofact show 21 companies demonstrated it, with "plenty of demonstrations but few available products." MAP later lost out to Ethernet; Wikipedia, citing a 2003 engineering handbook, blames changing specifications, costly interfaces and the slower token-passing scheme.

    LessonA network backed by one large buyer lost to cheaper, general-purpose Ethernet.

    historyofcomputercommunications.infohistoryofcomputercommunications.infoen.wikipedia.org

    Credit

    General Motors

  3. 1987

    Rival fieldbuses

    A fieldbus is a digital network that links many field instruments on one cable. PROFIBUS was launched in Germany in 1987 by a publicly sponsored alliance of 21 companies and institutions, the Fieldbus Foundation formed in 1994, and the 1990s became known as "the decade of the fieldbus wars." The international standard that settled them, IEC 61158, packed eight protocols into one document and, Control Engineering wrote in 2004, "ultimately produced little genuine interoperability."

    LessonWriting rival protocols into one standard did not make them work together.

    automationmag.comcontroleng.com

    Credit

    the PROFIBUS alliance; the Fieldbus Foundation; IEC

  4. 1996

    A common gateway for data

    The OPC Foundation was incorporated on 22 April 1996 by a group including Fisher-Rosemount, Rockwell Software, Opto 22 and Intellution, and released OPC Data Access 1.0 that August, a common way for software on Windows computers to read data from any maker's devices. Version 1.0 of its successor, OPC UA (Unified Architecture), became available on 28 July 2006.

    opcfoundation.orgautomationmag.com

    Credit

    OPC Foundation and its founding companies

  5. 2003

    Ethernet for the machine

    Beckhoff Automation introduced EtherCAT, an Ethernet-based network for machine control, in April 2003, and the EtherCAT Technology Group was founded that November; EtherCAT is now part of IEC 61158.

    ethercat.org

    Credit

    Beckhoff Automation

  6. 2016

    Cellular for small sensors

    3GPP, the body that writes mobile-network standards, completed NB-IoT (narrowband IoT), a cellular standard for low-power devices that send little data, in its Release 13 in June 2016, nine months after the study phase.

    3gpp.org

    Credit

    3GPP

  7. 2022

    Ethernet reaches the field

    Ethernet-APL (Advanced Physical Layer) carries Ethernet on two wires out to field instruments, including in areas with explosive atmospheres, over cables up to 1,000 m. The project between FieldComm Group, ODVA, the OPC Foundation and PROFIBUS & PROFINET International concluded in September 2022 with its specifications standardized and the first products released.

    ethernet-apl.orgethernet-apl.org

    Credit

    FieldComm Group, ODVA, OPC Foundation and PROFIBUS & PROFINET International

Watch for

  1. A network on a timetable

    IEC/IEEE 60802, published in June 2026, is a profile of time-sensitive networking (TSN), a set of Ethernet features that let control traffic arrive on a fixed schedule while other traffic shares the cable.

    Achieved whendevices from several makers that passed conformance tests carry control traffic together in working plants, and an outside party reports it.

    1.ieee802.org

    Claimed by

    IEEE 802.1 and IEC, June 2026

  2. Setup read from the manual

    Aadil Gani Ganie, Saad Ezzini and Naveed Farooz Marazi describe a pipeline in which an AI model reads makers' PDF manuals and writes the configuration for devices on Modbus RTU, OPC UA, PROFIBUS DP and CANopen networks. They report zero unsafe writes on a five-device benchmark, and a field-level F1 score (a combined measure of correct and missed fields) of 1.0 over three runs on a simulated Universal Robots UR5e robot set up from its 254-page manual.

    Achieved whenanother group reproduces the results on real devices.

    arxiv.org

    Claimed by

    the authors, in an arXiv preprint, August 2026

Open

  1. 01

    A register map per device

    An open library of machine-readable register maps, the tables that say which numbered location in a device holds which reading, in what units and at what scale, written by an AI agent from makers' PDF manuals and each checked by reading the real device.

    The brief
    Credit · unclaimed
  2. 02

    An open APL tally

    A public test bench where Ethernet-APL instruments and field switches from many makers are connected in every combination, with a published table of which pairs connect, report readings and accept settings, and which fail.

    The brief
    Credit · unclaimed

Open 01 · the brief

A register map per device

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An open library of machine-readable register maps, the tables that say which numbered location in a device holds which reading, in what units and at what scale, written by an AI agent from makers' PDF manuals and each checked by reading the real device.

Why it is still open

Device interfaces "are typically documented in PDF manuals that require manual interpretation," says OpenModbusSpecs, an open format for such maps started by the energy-management company Stekker in November 2025; in November 2026 its registry held seven stable device profiles. The August 2026 preprint above tested five devices and a simulated robot.

github.comarxiv.org

Built with what exists

the OpenModbusSpecs format (MIT licence); pymodbus, an open-source Python Modbus library, for live reads; AI models that extract tables from long manuals (see the Note "The jobs agents repeat"); low-cost Modbus devices such as energy meters and temperature controllers.

  1. First step

    Pick ten energy meters with public manuals, have a model write their profiles, and check one against a meter on the bench.

  2. Done looks like

    200 device profiles accepted into an open registry, each confirmed by a live read on real hardware, with the share of registers the agent got wrong before review published.

Open 02 · the brief

An open APL tally

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public test bench where Ethernet-APL instruments and field switches from many makers are connected in every combination, with a published table of which pairs connect, report readings and accept settings, and which fail.

Why it is still open

The multi-maker test led by Covestro at Endress+Hauser in May 2026, with a Yokogawa control system and switches from four vendors, was reported without device counts or results, and ARC wrote in 2026 that most installations are "lighthouse projects."

controldesign.comarcweb.com

Built with what exists

Ethernet-APL field switches and instruments on loan or bought from makers; a PLC or control system that speaks PROFINET; Wireshark to record the traffic; a shared test procedure.

  1. First step

    Ask two makers for loan devices, connect one instrument to one switch, and record every setup step and how long it took.

  2. Done looks like

    At least 20 instruments from at least six makers tested against switches from at least three, with every pairing's result and the procedure published.