Industries / Industrial equipment and services / Industrial services / Instrumentation and electrical
Motors and drives
This work installs, sets up and maintains the motors that turn a plant's pumps, fans and conveyors, and the drives, starters and motor control centers that switch and control them.
6
Milestones achieved, from 1968 to 2014.
1
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1968
Drives made in series
A variable-frequency drive (VFD) changes the frequency of the power fed to an AC motor, so the motor can run at the speed the job needs instead of the fixed speed the supply sets. Danfoss says it was the first company in the world to mass-produce AC drives, starting in 1968 with a pilot run of 10 VLT 5 drives sent to selected customers; the first generation was made until 1973. Ingeniøren, the Danish engineers' weekly, wrote in 2014 that the VLT reached the market in 1968 as the first commercial product of its kind and that competitors took several years to follow. A VLT 5 sold in the 1970s weighed 60 kg; Ingeniøren put a modern Danfoss drive of the same power at 13.5 kg.
LessonThe first prototypes came back from customers so fast that staff nicknamed them "homing pigeons", so the launch waited on long fault-finding in the field.
Credit
Danfoss, whose founder Mads Clausen hired the company's first electronics engineer in 1953
1969
Torque controlled apart from flux
In an induction motor the same stator current both magnetizes the motor and makes its torque, so changing one disturbs the other. Felix Blaschke of Siemens filed in Germany on 14 August 1969 for a method that splits the stator current into a part along the motor's rotating magnetic field and a part across it, so that field and torque can be controlled "independently of speed, and mutually decoupled". His US patent, 3,824,437, was granted on 16 July 1974, and patent offices class it under vector control by field orientation.
Credit
Felix Blaschke, Siemens
1980
A fast switch for drives
Around 1980 B. Jayant Baliga at General Electric created the insulated-gate bipolar transistor (IGBT), a power switch turned on and off by a small voltage on its gate that handles voltages too high for the MOSFETs of the time. A GE manager in charge of air-conditioner drives had asked the researchers for a way to run motors at variable speed. The first devices switched off too slowly for motor drives ("Maybe we can run a steam iron," colleagues said), until Baliga sped them up with electron irradiation; by his account the process was in production within months. Fuji Electric, Hitachi and Mitsubishi Electric took the device up, and IEEE Spectrum calls him the father of the silicon IGBT.
Credit
B. Jayant Baliga, General Electric
1981
Limits for converter harmonics
A drive's rectifier draws current in pulses rather than a smooth wave, and these harmonics, currents at multiples of the supply frequency, can heat equipment and disturb other users. IEEE 519, published on 27 April 1981 as a guide to harmonic control for static power converters in industrial and commercial plants, recommended limits on the disturbances that affect other equipment and communications. The 1992 edition, approved on 18 June 1992, widened it to harmonic control in power systems, and its successors set distortion limits at the point of common coupling (PCC), the interface between the supply and the plant's loads. The 2022 edition, published on 5 August 2022, became a full standard instead of a recommended practice.
Credit
IEEE's Industrial Power Converter committee (1981 edition); IEEE Power and Energy Society's Transmission and Distribution committee (2022 edition)
2007
A drive that stops safely
The first edition of IEC 61800-5-2, dated July 2007, sets requirements for drives used in safety functions, such as guard interlocks that keep people out until moving parts are safe. Its introduction says that before such standards there had been "a reluctance to accept" electronic and programmable devices in safety functions. The standard defines drive safety functions such as Safe Torque Off (STO), in which the drive stops supplying the power that makes torque, an uncontrolled stop of category 0 under EN 60204-1. Drive makers such as SEW-Eurodrive document STO "according to IEC 61800-5-2", switched by an external safety relay or safety controller.
Credit
IEC technical committee 22, power electronic systems and equipment
2014
Safer motor control centers
A motor control center (MCC) is a line-up of cabinets holding, in plug-in units, the breaker, contactor and overload relay for each motor, which technicians open to test, reset and replace. IEEE 1683-2014, approved on 16 May 2014 and published on 1 August 2014, gives design features and field practices meant to "help reduce the probability that an incident will occur due to shock or arc flash hazards when qualified persons are performing certain activities". It adds to the MCC product standards, NEMA ICS 18, UL 845 and CSA C22.2 No. 254, and sets out what the specifier, maker, installer and user each answer for. IEEE 1683-2025 replaced it.
Credit
IEEE Industry Applications Society's Petroleum and Chemical Industry Committee, working group chaired by Marcelo Valdes
Watch for
Nameplate photo sets the drive
SmartD Technologies' Clean Power VFD app, which sets up the company's Clean Power drives from a phone, added in version 2025.13 of 20 October 2025 a beta feature that fills in the motor nameplate parameters from a photo of the nameplate, using an AI service over the internet; a July 2026 update changed the Gemini model "to continue supporting AI nameplate scanner". ABB's Drivetune app does a related job by reading a QR code printed on ABB motor nameplates. Neither publishes how often the values come out right.
Achieved whenan outside party publishes field-by-field accuracy on a stated set of real nameplates, including worn and painted ones, checked against hand-read values.
Claimed by
SmartD Technologies, October 2025
Open
01
Score AI on drive faults
A public test of 300 drive troubleshooting questions. Each gives a drive model, the fault or alarm code on its display and what the technician sees (motor state, recent changes, readings), and asks for the likely causes in order and the checks to make. Answer keys come from the makers' manuals and are signed off by two drive technicians. General AI models and makers' assistants are scored on it.
The briefCredit · unclaimed02
A public nameplate test
A public set of 500 photos of real motor nameplates, NEMA and IEC, new and worn, painted over, dirty or in glare, each labeled by two people with the values a drive asks for (rated power, voltage, current, frequency, speed, power factor and connection). Readers are scored field by field against it.
The briefCredit · unclaimed
Open 01 · the brief
Score AI on drive faults
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public test of 300 drive troubleshooting questions. Each gives a drive model, the fault or alarm code on its display and what the technician sees (motor state, recent changes, readings), and asks for the likely causes in order and the checks to make. Answer keys come from the makers' manuals and are signed off by two drive technicians. General AI models and makers' assistants are scored on it.
Why it is still open
Danfoss has offered MyDrive Assistant since November 2022 to guide users to manuals and fixes for warning, fault and alarm codes, but has published no accuracy figures. An open project on GitHub, SXQ0607/vfd-fault-codes (September 2026), gathers more than 1,000 fault codes, with causes and checks, from 16 brands' manuals into a lookup tool, and scores nothing. The nearest published test, by Sarah Lukens and colleagues at LMI (PHM Society, 2025), recommends fault codes for a ground vehicle from synthetic data and found that retrieving manual passages beat AI models at matching the right code. Searches found no such test for drives.
Built with what exists
Public PDF manuals for five drive families, for example Siemens SINAMICS G120, ABB ACS580, Danfoss VLT FC 302, Yaskawa A1000 and Rockwell PowerFlex 525; the GitHub table as a first index, checked against the manuals; general AI models through their APIs and an open-weight model run on site, such as Mistral Large 4 (see the Note "A trillion open parameters"); a short scoring script.
First step
Pull the fault tables from two drive manuals and write the first 50 questions with answers.
Done looks like
300 questions across five drive families, answer keys signed by two technicians, and published scores for at least five AI systems, split by error type: wrong cause, missed safety step, and invented codes or parameters.
Open 02 · the brief
A public nameplate test
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public set of 500 photos of real motor nameplates, NEMA and IEC, new and worn, painted over, dirty or in glare, each labeled by two people with the values a drive asks for (rated power, voltage, current, frequency, speed, power factor and connection). Readers are scored field by field against it.
Why it is still open
SmartD's AI nameplate scanner is still in beta and ABB's Drivetune reads only a QR code on ABB motors. An open reader on GitHub, mrchandrayee/motor_nameplate_reader_project (November 2026), pulls 17 fields from a photo with EasyOCR and OpenCV but publishes no accuracy, and its own notes say accuracy depends on image quality and plate condition. The public nameplate sets found on Hugging Face and Roboflow are for finding plates in images or hold a few dozen general nameplates, such as one of 30 image and text pairs, and none is labeled with motor ratings or scores readers.
Built with what exists
Phone cameras; Label Studio for labeling; vision-language AI models, including Gemini, which SmartD's app uses, and open-weight alternatives; the open GitHub reader as a baseline.
First step
Photograph and label 50 nameplates on disconnected spare motors in a storeroom or repair shop.
Done looks like
500 labeled photos published under an open license, per-field accuracy for at least three readers, and the share of photos where a reader's rated current is more than 5% off, the value a drive uses for its motor overload protection.