Plant control systems

A plant control system, called a distributed control system (DCS) in the trade, runs a whole refinery, chemical plant or mill from one control room, with many controllers sharing one database, one network and one set of operator screens.

4

Milestones achieved, from 1996 to 2019.

1

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1996

    A control system on Windows

    Fisher-Rosemount, now part of Emerson, launched DeltaV, a control system written from scratch for Microsoft Windows NT. It ran on standard desktop PCs linked by ordinary 10 Mbit/s Ethernet, kept all its settings in one database, and was configured by dragging reusable templates of control strategies onto the screen. At its UK launch the trade magazine Process Engineering reported that three months after the US launch it was installed at 24 US sites, ten of them beta test sites, and at five in Europe; the first UK system ran boiler control at Staveley Chemicals in Derbyshire. Emerson's own timeline calls it "the first commercial, off-the-shelf, digital control system."

    processengineering.co.ukemerson.com

    Credit

    Fisher-Rosemount (Emerson)

  2. 2002

    Two thirds of loops underperform

    A control loop is one measurement, one controller and one valve or motor working together, and most use the PID (proportional-integral-derivative) algorithm, 97% of regulatory loops in an earlier survey of more than 11,000. Lane Desborough and Randy Miller of Honeywell Hi-Spec Solutions graded 26,000 PID controllers from continuous process plants: 16% excellent, 16% acceptable, 22% fair, 10% poor and 36% "open loop," meaning in manual or with the output stuck at a limit more than 30% of the time. Only one third performed acceptably. In 2020 Dennis Nash of Control Station, a maker of loop-monitoring software, reported data from 116 plants in which 14% of controllers spent most of their time out of their normal mode.

    LessonInstalling a control system does not make its loops work, and a plant that does not measure them does not know.

    skoge.folk.ntnu.noisa.org

    Credit

    Lane Desborough and Randy Miller, Honeywell

  3. 2013

    Wiring sorted in software

    In a conventional plant control system, field wiring is sorted by hand in a marshalling cabinet before it reaches the input and output modules, so a late change to an instrument means rewiring. In electronic marshalling every channel is set in software as analog, digital or HART. Invensys introduced Intelligent Marshalling for its Foxboro I/A Series on 8 November 2011, Control Global reported, and Emerson said in September 2013 that its CHARMs, developed first for offshore platforms where space is short and late design changes are costly, had logged 1 billion operating hours at more than 300 sites. Bryan Beyer of Southern States Chemical, the first North American plant to install CHARMs, reported "a 40 percent drop in installation costs over traditional approaches."

    automation.comcontrolglobal.com

    Credit

    Emerson (CHARMs for DeltaV) and Invensys (Intelligent Marshalling)

  4. 2019

    A package unit plugs in

    A package unit is equipment bought ready-built with its own controller, such as a chiller. At Evonik's amino-acid plant in Singapore a chiller from ENGIE, run by a Siemens S7-1500 PLC, was joined to the site's Yokogawa CENTUM VP control system by importing a Module Type Package (MTP), a standard file (VDI/VDE/NAMUR 2658) that describes a unit's functions, data and operator screens. Start-up was in June 2019. Data flowed over OPC UA "without error immediately after physically connecting the systems," and the chiller's screens took on the look of the main plant's. Chemical Processing called it the first industrial use of the MTP standard; the chiller's own controls ran in monitoring-only mode because of warranty terms.

    LessonA shared file format replaces custom integration only when both sides build to the same version of it, and in June 2024 the PROFIBUS user organization, which maintains MTP, said its parts existed in "many different, partially inconsistent versions.".

    chemicalprocessing.comse.profibus.com

    Credit

    Evonik, ENGIE, Siemens and Yokogawa

Watch for

  1. Process control as server software

    Emerson says the DeltaV IQ Controller, offered with DeltaV version 16.LTS from 20 January 2026, is "a fault-tolerant, modular, software-defined controller deployed in a server-based environment and able to handle the most demanding process control applications." Schneider Electric announced EcoStruxure Foxboro Software Defined Automation on 13 February 2026, a control system that "separates hardware and software" and is built on its EcoStruxure Automation Expert software.

    Achieved whena plant operator reports routine closed-loop control of a process on either product, with measured availability and the result of a forced switch to the backup.

    emerson.comcontroleng.com

    Claimed by

    Emerson, January 2026; Schneider Electric, February 2026

Open

  1. 01

    An MTP pairing table

    A public test in which module files (MTPs) exported by every available module engineering tool are imported into every available orchestration system, the software that runs many modules as one plant. Each pairing is scored on whether the module's services start, hold and stop on command, whether its readings arrive, and whether its screens draw correctly.

    The brief
    Credit · unclaimed
  2. 02

    MTPs for units already built

    An AI agent that reads an existing package unit's tag list, program export and manual and writes its MTP file, plus the interface layer that maps the old controller's data to the standard's OPC UA model, so that a unit bought before the standard can join an orchestration system without being reprogrammed.

    The brief
    Credit · unclaimed

Open 01 · the brief

An MTP pairing table

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public test in which module files (MTPs) exported by every available module engineering tool are imported into every available orchestration system, the software that runs many modules as one plant. Each pairing is scored on whether the module's services start, hold and stop on command, whether its readings arrive, and whether its screens draw correctly.

Why it is still open

The PROFIBUS user organization (PNO), which maintains the standard, said in June 2024 that "projects with products from multiple vendors have to ensure that the products fit together." Its multi-vendor demonstration joined 10 orchestration systems from 8 vendors with 12 module solutions from 11 vendors, without a published table of which pairs worked, and it planned conformance tests for 2025. The first plant integration, at Evonik in 2019, hit import problems with screen object sizes and OPC UA name spaces.

se.profibus.comchemicalprocessing.com

Built with what exists

makers' MTP export and import tools on trial licences; open62541, an open-source OPC UA library (Mozilla Public License 2.0), to build simulated modules; the published parts of VDI/VDE/NAMUR 2658; Wireshark to record the OPC UA traffic.

  1. First step

    Build one simulated module, a heater with one heating service, as an open62541 server, write its MTP by hand, import it into one orchestration tool and log every step that fails.

  2. Done looks like

    At least 8 module files from at least 5 makers imported into at least 5 orchestration systems, with every pairing's result, its error messages and the test procedure published.

Open 02 · the brief

MTPs for units already built

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

An AI agent that reads an existing package unit's tag list, program export and manual and writes its MTP file, plus the interface layer that maps the old controller's data to the standard's OPC UA model, so that a unit bought before the standard can join an orchestration system without being reprogrammed.

Why it is still open

MTP was first used in a plant in 2019, so units built before then carry no such file. In that first project, writing and importing one chiller's file took several workshops between the unit's supplier and its automation vendor and two prototype tools, and in June 2024 PNO still counted more than 25 MTP products and more than 50 proof-of-concept projects.

chemicalprocessing.comse.profibus.com

Built with what exists

AI models that read long manuals and tables (see the Note "The jobs agents repeat"); the unit maker's own program export; open62541 to serve the mapped data over OPC UA; an orchestration tool to import and test the result.

  1. First step

    Write a tag list and a two-page manual for a two-pump dosing skid, have a model produce its MTP, and import it into one orchestration tool.

  2. Done looks like

    For 10 package units' document sets, the agent's MTP files import into an orchestration tool and pass a scripted start, hold and stop test against a simulated copy of each unit, with the share of files that needed hand edits published.