BRENNEN

Industries / Energy, water and waste / Power generation / Hydroelectric

Turbines and generators

This is the work of designing, building and running the machines that turn falling water into electricity: the turbine, whose spinning part (the runner) is pushed by the water, and the generator on the same shaft.

6

Milestones achieved, from 1827 to 2022.

2

To watch for: announced, not yet confirmed outside.

2

Open deliverables. Nobody has shipped them.

The road

AchievedWatch forOpen

Achieved

  1. 1827

    Fourneyron's first turbine

    In April 1827 Benoît Fourneyron installed his first water turbine at Pont-sur-l'Ognon in eastern France, rated at six horsepower under a 1.40 m drop, to drive a sawmill, a lathe and a grindstone, by the French heritage inventory's account. In his design the water was led through fixed guide blades and then outward through the vanes of an enclosing wheel, giving up nearly all its swirl to the wheel; a 1927 account in The Engineer, reprinted by Grace's Guide, says one of his turbines ran under a 354 ft (108 m) head at 2,300 revolutions per minute in 1837, and that the first two 5,000-horsepower turbines installed at Niagara in 1895 were of Fourneyron's type.

    pop.culture.gouv.frgracesguide.co.uk

    Credit

    Benoît Fourneyron

  2. 1849

    Water flows inward

    James B. Francis, chief engineer of the canal company at Lowell, Massachusetts, used tests of his 1847 turbine to design a much improved model with curved guides and buckets for the Boott Mills in 1849. Water enters it around the outside and flows inward through the runner. Francis published his measurements as Lowell Hydraulic Experiments in 1855. ASME says the Francis type, developed from a wheel Samuel Howd patented in 1838, is the most widely used water turbine for medium heads and large flows, and that most turbines used to make hydroelectric power today are called Francis turbines.

    asme.orgasme.org

    Credit

    James B. Francis, Proprietors of Locks and Canals, Lowell

  3. 1880

    The split bucket

    A Pelton wheel is turned by a jet of water striking buckets around its rim, and suits sites where water falls a long way. Lester A. Pelton built his first one at Camptonville, California, in 1878, developed from the "hurdy gurdy" wheels of the gold fields, and patented the splitter bucket, which divides the jet in two, on 26 October 1880 (US Patent 223,692). ASME says the splitter principle "appears original" to Pelton. From 1899 William A. Doble patented better bucket and nozzle shapes and became chief engineer of Pelton's company in 1912.

    asme.org

    Credit

    Lester A. Pelton; William A. Doble

  4. 1913

    Blades that adjust

    Viktor Kaplan filed patent applications in Europe in 1913 for a propeller-type turbine whose runner blades and inlet gates are adjusted together, which ASME's landmark brochure says he was the first to do. The First World War delayed its use until after 1920; by 1930 such turbines were installed almost wherever the head (the height the water falls) suited them, because they keep a high, nearly constant efficiency over a wide range of loads. One of the first three in the United States, built by the S. Morgan Smith Company, went into service at York Haven, Pennsylvania, on 5 April 1929 under a 23 ft head.

    asme.orgasme.org

    Credit

    Viktor Kaplan; S. Morgan Smith Company

  5. 2009

    Sayano-Shushenskaya unit 2 fails

    At 8:13 a.m. on 17 August 2009, at the 6,400 MW Sayano-Shushenskaya plant in Russia, the 1,860-ton cover of Unit 2's turbine was blown off and water under a 212 m head threw the spinning rotor out of its pit; 75 workers died. Examination of the broken bolts that held the cover found fatigue damage across an average of 65% of each bolt's cross-section, and some nuts had never been fitted. The unit's bearing vibration had risen fourfold since April 2009 and was 840 µm against an allowed 160 µm, and on the night before it had passed several times through an operating range marked "not recommended". Afterwards the wicket gates, the adjustable vanes that let water into the turbine, were redesigned to close automatically if power is lost.

    Lessona vibration limit protects a machine only if someone is required to shut it down when the limit is passed.

    powermag.com

    Credit

    RusHydro (owner); findings as reported by POWER magazine

  6. 2022

    Units of 1,000 MW

    The last of the 16 generating units at Baihetan in China, each rated 1,000 MW, entered operation in December 2022, completing a 16 GW plant, by Water Power Magazine's report. China's government reported that the chairman of China Three Gorges Corporation, which built it, said each unit has the largest single-unit capacity in the world.

    waterpowermagazine.comenglish.www.gov.cn

    Credit

    China Three Gorges Corporation

Watch for

  1. A 500 MW Pelton unit

    Dongfang Electric is supplying one of two 500 MW impulse units with Pelton turbines for the Datang Zhala hydropower station in Xizang (Tibet), which People's Daily calls the world's first 500 MW impulse hydropower units. The inlet valve of Unit 1 passed its pressure test in July 2026, and the rotor was lifted into place in August 2026, which Global Times describes as the last stage before commercial launch.

    Achieved whenUnit 1 delivers power at or near 500 MW and someone other than the builders and owner reports it running.

    interestingengineering.comglobaltimes.cn

    Claimed by

    Dongfang Electric and Chinese state media, July and August 2026

  2. Vibration warnings a month early

    Dewesoft, a measurement company, and the Croatian utility HEP report a machine-learning model of shaft vibration on a hydro generating unit in Croatia. Replayed on 2020–2021 data from before a fault that led to the generator's complete shutdown, it showed deviations up to 47 days before conventional alarms would have sounded; the model was not running at the time, and the authors report no live catch since it went into production in July 2024.

    Achieved whenrunning live, it flags a developing fault on an operating unit before standard alarms, with its false alarms counted, as reported by the plant owner or an outside reviewer.

    dewesoft.com

    Claimed by

    Dewesoft with HEP, May 2026

Open

  1. 01

    Open recordings from working units

    A free, labeled collection of vibration and sound recordings from operating hydro units, logged with each unit's output in megawatts, covering normal running, rough part-load running and faults later confirmed by maintenance records, with a baseline detector that others can try to beat.

    The brief
    Credit · unclaimed
  2. 02

    Counting starts across Europe

    A public table of how often each large conventional hydro unit in Europe starts, stops and runs below half its rated output, year by year since 2015, built from the output that EU rules require grid operators to publish for every generating unit of 100 MW or more.

    The brief
    Credit · unclaimed

Open 01 · the brief

Open recordings from working units

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A free, labeled collection of vibration and sound recordings from operating hydro units, logged with each unit's output in megawatts, covering normal running, rough part-load running and faults later confirmed by maintenance records, with a baseline detector that others can try to beat.

Why it is still open

Oak Ridge National Laboratory (ORNL) writes that the unit-level data the Hydropower Research Institute pools from US owners, 160 units at 34 sites in 2021, are "proprietary and non-public". A 2025 open-source project for detecting faults in hydro generators by sound says its raw data "cannot be publicly released". The EU Di-Hydro project's dataset of vibration, flow and acoustic data from hydro plants is restricted and "not intended for public dissemination".

info.ornl.govgithub.comzenodo.org

Built with what exists

Contact microphones and USB accelerometers fixed by plant staff, or a university turbine test rig; the plant's own output log; Microsoft's BEATs audio model (in its unilm repository); the MIT-licensed code from the project above; the Anomalib anomaly-detection library; Zenodo to publish with a citable DOI.

  1. First step

    Ask two owners of small hydro plants and one university turbine laboratory whether their staff would record one unit across its full load range this month.

  2. Done looks like

    Recordings from at least 12 units at four or more plants and at least two turbine types, at least three fault events labeled from maintenance records, released under an open license, with a baseline whose detection rate and false alarms per month of normal running are published.

Open 02 · the brief

Counting starts across Europe

Credit · unclaimed

The first to publish is credited on this line, and the deliverable moves from Open to Achieved.

What to build

A public table of how often each large conventional hydro unit in Europe starts, stops and runs below half its rated output, year by year since 2015, built from the output that EU rules require grid operators to publish for every generating unit of 100 MW or more.

Why it is still open

Each start and each hour at part load wears turbines and generators. SINTEF researchers Arnt Ove Eggen and Michael Belsnes model the cost of one start for single units, noting that more frequent starts follow from swings in market prices. Norway's HydroCen research center, which studied stator wear at a few Norwegian plants, says "more data is needed from several power plants". The EU rule requires actual output per market time unit for every unit of 100 MW or more. Searches of papers, Zenodo and GitHub found no count of starts or part-load hours across the fleet.

doi.orghydrocen.nina.nolegislation.gov.uk

Built with what exists

The ENTSO-E Transparency Platform's API (free registration); entsoe-py, an MIT-licensed Python client; pandas; a coding agent such as GitHub Copilot to write the pipeline (see the Note "Effort, not model").

  1. First step

    Register for an API key and count starts per unit for one Alpine and one Nordic country in 2015 and 2025.

  2. Done looks like

    Every conventional hydro unit the platform lists, with starts per year and hours below half load for 2015–2025, published with code; a second person checks 30 random unit-years against the raw series; the trend reported whether it rises or not, with a note that starts shorter than one market time unit are missed. Pumped storage units are left to a separate study.