Testing and service
This work is the routine starting, loading, inspecting and repairing of generator sets and turbine-generators, so that they start and carry load when the normal supply fails.
5
Milestones achieved, from 1988 to 2016.
2
To watch for: announced, not yet confirmed outside.
2
Open deliverables. Nobody has shipped them.
The road
AchievedWatch forOpen
Achieved
1988
Station blackout becomes a rule
The US Nuclear Regulatory Commission added 10 CFR 50.63, which requires every light-water nuclear plant to withstand and recover from a station blackout, a total loss of off-site and on-site AC power, for a set time. How reliable the plant's emergency AC sources are helps set that time.
LessonA backup generator's measured reliability, not just its presence, became a figure regulators track.
Credit
US Nuclear Regulatory Commission (53 FR 23215, 21 June 1988)
1996
Diesel failures counted
Idaho National Engineering Laboratory studied emergency diesel generator trains at US nuclear plants from 1987 to 1993 for the NRC (NUREG/CR-5500, Volume 5): 50 failures in 181 real demands and 682 scheduled tests. It put train unreliability at 0.044, or 0.069 if failed units could not be restored, and found about 70% of it came from a diesel being out for maintenance when needed; in about half of control-circuit failures, no cause was found.
LessonTime out for maintenance is itself a large source of unavailability, and intermittent faults are hard to diagnose.
Credit
Idaho National Engineering Laboratory for the US NRC
1999
Monthly test tied to nameplate
The 1999 edition of NFPA 110 measured the monthly load test against the generator's nameplate rating. Running a diesel below about 30% of its rating risks wet stacking, unburned fuel and carbon building up in the exhaust because the engine never gets hot enough. The current wording asks for at least 30 minutes a month at 30% or more of standby nameplate kW or at the maker's minimum exhaust temperature, with a load bank (a rack of resistors that soaks up power) making up any shortfall.
Credit
NFPA 110 Technical Committee
2011
Fukushima diesels lost to water
After the 11 March earthquake cut grid power, the diesel generators at Fukushima Dai-ichi ran for about 40 minutes until a tsunami estimated at 14 m damaged many of them, and four of six reactors lost all generator power. A Unit 6 diesel kept running and held Units 5 and 6 in safe shutdown. In March 2012 the NRC ordered US plants to keep key safety functions working even if installed power sources fail.
LessonA well-tested generator still fails if it and its switchgear sit where water can reach them.
Credit
lessons drawn by the US NRC
2016
Robots inspect without pulling rotors
GE agreed to inspect 19 generators at Alinta Energy's gas-fired plants in Australia and New Zealand with its DIRIS robot, which carries a camera into the air gap between rotor and stator to look for wear, dirt and loose wedges. Removing a rotor had cost Alinta about three weeks; a robot inspection takes two to three days, which let Alinta plan major inspections every four years instead of every eight, GE reported.
Credit
GE Power, with Alinta Energy
Watch for
Baffle-crossing generator inspection robot
The Hong Kong Polytechnic University and CLP Power built a 36 mm-thick robot that travels the rotor-stator air gap, climbs over internal ventilation baffles, checks ducts and core laminations (the stacked steel sheets of the stator) and taps wedges to test tightness, without removing a rotor of about 50 tonnes. It was tested at Black Point Power Station; no figures for time saved were given.
Achieved whenCLP or another utility reports using it in routine outages, with measured outage time or findings.
Claimed by
PolyU (Prof. Tam Hwa-yaw) and CLP Power, April 2026
AI assistant for genset diagnosis
Oncaire, a Florida start-up, offers a service that reads a generator's nameplate from a phone photo and guides technicians through diagnosis with an AI model trained on manuals and wiring diagrams. It says pilots with makers show a "double-digit reduction" in time to diagnose, and calls the system still in the pilot stage.
Achieved whena named maker or fleet owner publishes measured diagnosis-time or first-time-fix results.
Claimed by
Oncaire LLC, August 2025
Open
01
Open labelled genset fault sounds
A public set of vibration and sound recordings from small portable generators of about 2 to 8 kW with faults put in on purpose: a fouled spark plug, a restricted air filter, an unbalanced load, a loose mount, low oil and light-load running. Each recording is labelled with fault, load and engine hours.
The briefCredit · unclaimed02
Open nuclear diesel failure table
An AI reader that takes public NRC Licensee Event Reports (LERs, the event reports nuclear plants must file) about emergency diesel generators and pulls out plant, date, failure mode (fail to start, fail to load and run, fail to run), subcomponent, cause and how the fault was found, into an open table with every row checked by hand. A long-document reviewer of the kind in the Note "Seven more flagged" fits the extraction step.
The briefCredit · unclaimed
Open 01 · the brief
Open labelled genset fault sounds
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
A public set of vibration and sound recordings from small portable generators of about 2 to 8 kW with faults put in on purpose: a fouled spark plug, a restricted air filter, an unbalanced load, a loose mount, low oil and light-load running. Each recording is labelled with fault, load and engine hours.
Why it is still open
Searches of Zenodo, Kaggle, Hugging Face and arXiv in November 2026 for genset, diesel generator and misfire fault data found no labelled engine-generator set; the closest are machinery test rigs, such as a UET Taxila rig with crack, pulley and wear faults, and published diesel-generator AI papers use private data.
Built with what exists
A consumer inverter generator; ADXL345 accelerometers and a USB measurement microphone; a Raspberry Pi logger; plug-in heaters as a load; Python with librosa and scikit-learn; Zenodo or Hugging Face under CC BY 4.0.
First step
Mount two accelerometers and a microphone on one inverter generator and record healthy running at no load, 30% and 75% load.
Done looks like
At least 6 fault classes plus healthy, each at 3 load levels and at least 30 minutes per class, with a baseline classifier's accuracy reported on a held-out session and build notes another person can follow.
Open 02 · the brief
Open nuclear diesel failure table
The first to publish is credited on this line, and the deliverable moves from Open to Achieved.
What to build
An AI reader that takes public NRC Licensee Event Reports (LERs, the event reports nuclear plants must file) about emergency diesel generators and pulls out plant, date, failure mode (fail to start, fail to load and run, fail to run), subcomponent, cause and how the fault was found, into an open table with every row checked by hand. A long-document reviewer of the kind in the Note "Seven more flagged" fits the extraction step.
Why it is still open
INL's 2022 study of emergency diesel performance for the NRC, covering 234 diesels from 1998 to 2020, rests on the industry's IRIS database, which is not public. A search for AI or text-mining classification of diesel LERs found none; the nearest, Xian and colleagues on arXiv in 2024, classified shutdown events and not diesels.
Built with what exists
NRC ADAMS public document search; Python with pdfplumber; an open-weight or hosted language model for structured extraction; SQLite or a spreadsheet; a hand-check log.
First step
Pull 50 LERs from 2015 to 2024 that mention "emergency diesel generator", label them by hand as a gold set, then run the extractor and measure agreement.
Done looks like
At least 300 diesel LERs tabulated, a hand-checked sample of at least 100 with accuracy reported field by field, and failure-mode counts compared with INL's published counts.